Opublikuj swoje produkty
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK

    Model 8611 Corner RiserPACK

    4.6 out of 5 stars4.6(12 reviews)

    AGF's commercial RiserPACK Model 8611 is a riser manifold for NFPA 13 fire sprinkler systems and is designed to fit into a corner to minimize protruding and comply with ADA Standards. Model 8611 includes a flow switch, TESTanDRAIN Model 1011A with included pressure relief valve and trim, Model 7600 3-way universal gauge valve, and a Model 7500 pressure gauge. Available with a steel body in sizes 2"-6", orifice sizes 3/8" (K 2.8) - 25K, and a groove x groove connection. AGF's corner manifold is available with a right or left drain to accommodate every installation configuration.

    Opis
    • Model 8611 Commercial Corner RiserPACK

      1. 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:
        1. Product: Commercial Model M8611. Includes a flow switch, TESTanDRAIN Model 1011A, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge and a model M7000 Pressure Relief Valve.
          1. Riser Model: Pre-Assembled TESTanDRAIN Riser 2, 2-1/2, 3, 4, and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm):
            1. Inlet and Outlet (Schedule 10 steel): Grooved 2, 2-1/2, 3, 4 and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm) Models.
            2. Schedule 10 fabricated steel body with 3mil (.08 mm) powder coated red finish.
            3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
            4. Pressure Rating: 300 psig (2070 kPa).
            5. Size: Same as connected piping.

      ** NOTE TO SPECIFIER ** Delete valve not required.

      1. Valve Model 1011 TESTanDRAIN valve for a 2 inch (51 mm) Model:
        1. 1 inch (25 mm) FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      1. Valve Model 1011 TESTanDRAIN valve for a 4 or 6 inch (102 mm, 152 mm) Models:
        1. 2 inch FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 25.2K, as required by NFPA 13, latest edition.
      8. Water flow alarm switch.
      9. Pressure Gauge: AGF Model 7500.
      10. 1/4 inch, 3-way globe valve: AGF Model 7600
      11. Pressure Relief Valve and Drainage Piping: AGF Model 7000 or AGF Lockable Model 7000L

      ** NOTE TO SPECIFIER ** Delete pressure rating not required.

      1. Pressure Rating: Factory rated at 175 PSI.
      2. Pressure Rating: 200 PSI.
      3. Pressure Rating: 225 PSI.
      4. Pressure Rating: 300 PSI.
      5. Body Material: Bronze body and stainless steel spring.
      6. Components: Nylobraid flexible tube, Two 1/2 inch (13 mm) NPT by barbed 90 degree elbows, external identification plate and integral flushing handle to remove debris.
      7. 1/2 inch (13 mm) MIPT inlet, 1/2 inch (13 mm) FIPT outlet.
      8. Relief pressure shall be factory set to project specifications.
      9. Relief valve shall operate to the OPEN position between 90% and 105% of the set pressure.
      10. Relief valve shall reseat or CLOSE at a minimum of 80% of set pressure.
    Specyfikacja techniczna
    • Nr referencyjnyAGF-Corner-Riser
    • Rodzina produktuAGF Fire Sprinkler Products
    • Grupa produktuRiserPACK®
    • Data publikacji2022-03-02
    • Numer edycji1
    Dodatkowe informacje
    • Materiał głównyStal malowana proszkowo
    • Zaprojektowano wStany Zjednoczone
    • Wyprodukowano wStany Zjednoczone
    Klasyfikacja
    • Kategoria BIMobjectOchrona przeciwpożarowa - System zraszaczy
    • CSI MasterFormat 2014 Code21 00 00
    • CSI MasterFormat 2014 TitleFire Suppression
    • OmniClass Number23-29 33 00
    • OmniClass TitleFire Suppression System Components
    • CSI UniFormat II CodeD40
    • CSI UniFormat II TitleFIRE PROTECTION

    Dostępny w krajach:

    Azja Europa Afryka Ameryka Południowa Oceania Ameryka północna
    Afganistan
    Albania
    Algieria
    Argentyna
    Australia
    Bahamy
    Arabia Saudyjska
    Austria
    Angola
    Boliwia
    Fidżi
    Belize
    Armenia
    Belgia
    Benin
    Brazylia
    Nowa Kaledonia
    Dominikana
    Azerbejdżan
    Białoruś
    Botswana
    Chile
    Nowa Zelandia
    Grenlandia
    Bangladesz
    Bośnia i Hercegowina
    Burkina Faso
    Ekwador
    Papua-Nowa Gwinea
    Gwatemala
    Bhutan
    Bułgaria
    Burundi
    Falklandy (Malwiny)
    Timor Wschodni
    Haiti
    Chiny
    Chorwacja
    Czad
    Gujana
    Vanuatu
    Honduras
    Filipiny
    Cypr
    Demokratyczna Republika Konga
    Gujana Francuska
    Wyspy Salomona
    Jamajka
    Gruzja
    Czarnogóra
    Dżibuti
    Kolumbia
    Kanada
    Indie
    Czechy
    Egipt
    Paragwaj
    Kostaryka
    Indonezja
    Dania
    Erytrea
    Peru
    Kuba
    Irak
    Estonia
    Etiopia
    Surinam
    Meksyk
    Iran
    Finlandia
    Gabon
    Urugwaj
    Nikaragua
    Izrael
    Francja
    Gambia
    Wenezuela
    Panama
    Japonia
    Grecja
    Ghana
    Portoryko
    Jemen
    Hiszpania
    Gwinea
    Salwador
    Jordania
    Holandia
    Gwinea Bissau
    Stany Zjednoczone
    Kambodża
    Irlandia
    Gwinea Równikowa
    Katar
    Islandia
    Kamerun
    Kazachstan
    Litwa
    Kenia
    Kirgistan
    Łotwa
    Kongo
    Korea Północna
    Luksemburg
    Lesotho
    Korea Południowa
    Macedonia Pólnocna
    Liberia
    Kuwejt
    Mołdawia
    Libia
    Laos
    Niemcy
    Madagaskar
    Liban
    Norwegia
    Malawi
    Malezja
    Polska
    Mali
    Mongolia
    Portugalia
    Maroko
    Myanmar (Birma)
    Rosja
    Mauretania
    Nepal
    Rumunia
    Mozambik
    Oman
    Serbia
    Namibia
    Pakistan
    Słowacja
    Niger
    Palestyna
    Słowenia
    Nigeria
    Sri Lanka
    Svalbard
    Republika Południowej Afryki
    Syria
    Szwajcaria
    Republika Środkowoafrykańska
    Tadżykistan
    Szwecja
    Rwanda
    Tajlandia
    Ukraina
    Sahara Zachodnia
    Tajwan
    Węgry
    Senegal
    Turcja
    Wielka Brytania
    Sierra Leone
    Turkmenistan
    Włochy
    Somalia
    Uzbekistan
    Suazi
    Wietnam
    Sudan
    Zjednoczone Emiraty Arabskie
    Sudan Południowy
    Tanzania
    Togo
    Tunezja
    Uganda
    Wybrzeże Kości Słoniowej
    Zambia
    Zimbabwe