Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK

    Model 8611 Corner RiserPACK

    4.6 out of 5 stars4.6(12 reviews)

    AGF's commercial RiserPACK Model 8611 is a riser manifold for NFPA 13 fire sprinkler systems and is designed to fit into a corner to minimize protruding and comply with ADA Standards. Model 8611 includes a flow switch, TESTanDRAIN Model 1011A with included pressure relief valve and trim, Model 7600 3-way universal gauge valve, and a Model 7500 pressure gauge. Available with a steel body in sizes 2"-6", orifice sizes 3/8" (K 2.8) - 25K, and a groove x groove connection. AGF's corner manifold is available with a right or left drain to accommodate every installation configuration.

    Spesifikasjon
    • Model 8611 Commercial Corner RiserPACK

      1. 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:
        1. Product: Commercial Model M8611. Includes a flow switch, TESTanDRAIN Model 1011A, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge and a model M7000 Pressure Relief Valve.
          1. Riser Model: Pre-Assembled TESTanDRAIN Riser 2, 2-1/2, 3, 4, and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm):
            1. Inlet and Outlet (Schedule 10 steel): Grooved 2, 2-1/2, 3, 4 and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm) Models.
            2. Schedule 10 fabricated steel body with 3mil (.08 mm) powder coated red finish.
            3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
            4. Pressure Rating: 300 psig (2070 kPa).
            5. Size: Same as connected piping.

      ** NOTE TO SPECIFIER ** Delete valve not required.

      1. Valve Model 1011 TESTanDRAIN valve for a 2 inch (51 mm) Model:
        1. 1 inch (25 mm) FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      1. Valve Model 1011 TESTanDRAIN valve for a 4 or 6 inch (102 mm, 152 mm) Models:
        1. 2 inch FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 25.2K, as required by NFPA 13, latest edition.
      8. Water flow alarm switch.
      9. Pressure Gauge: AGF Model 7500.
      10. 1/4 inch, 3-way globe valve: AGF Model 7600
      11. Pressure Relief Valve and Drainage Piping: AGF Model 7000 or AGF Lockable Model 7000L

      ** NOTE TO SPECIFIER ** Delete pressure rating not required.

      1. Pressure Rating: Factory rated at 175 PSI.
      2. Pressure Rating: 200 PSI.
      3. Pressure Rating: 225 PSI.
      4. Pressure Rating: 300 PSI.
      5. Body Material: Bronze body and stainless steel spring.
      6. Components: Nylobraid flexible tube, Two 1/2 inch (13 mm) NPT by barbed 90 degree elbows, external identification plate and integral flushing handle to remove debris.
      7. 1/2 inch (13 mm) MIPT inlet, 1/2 inch (13 mm) FIPT outlet.
      8. Relief pressure shall be factory set to project specifications.
      9. Relief valve shall operate to the OPEN position between 90% and 105% of the set pressure.
      10. Relief valve shall reseat or CLOSE at a minimum of 80% of set pressure.
    Tekniske spesifikasjoner
    • Unik ref.AGF-Corner-Riser
    • ProduktfamilieAGF Fire Sprinkler Products
    • ProduktgruppeRiserPACK®
    • Utgivelsesdato2022-03-02
    • Utgavenummer1
    Relatert
    • HovedmaterialePulvermalt stål
    • Designet iUSA
    • Produsert iUSA
    Klassifisering
    • BIMobject kategoriBrannprodukter - Sprinklersystemer
    • CSI MasterFormat 2014 kode21 00 00
    • CSI MasterFormat 2014 tittelFire Suppression
    • OmniClass-nummer23-29 33 00
    • OmniClass-tittelFire Suppression System Components
    • CSI UniFormat II kodeD40
    • CSI UniFormat II tittelFIRE PROTECTION

    Tilgjengelighet etter region

    Asia Europa Afrika Sør Amerika Oceania Nord Amerika
    Afghanistan
    Albania
    Algerie
    Argentina
    Australia
    Bahamas
    Armenia
    Belgia
    Angola
    Bolivia
    Fiji
    Belize
    Aserbajdsjan
    Bosnia-Hercegovina
    Benin
    Brasil
    New Zealand
    Canada
    Bangladesh
    Bulgaria
    Botswana
    Chile
    Ny-Caledonia
    Costa Rica
    Bhutan
    Danmark
    Burkina Faso
    Colombia
    Øst-Timor
    Cuba
    De forente arabiske emirater
    Estland
    Burundi
    Ecuador
    Papua Ny-Guinea
    Den dominikanske republikk
    Filippinene
    Finland
    Den demokratiske republikken Kongo
    Falklandsøyene (Malvinas)
    Salomonøyene
    El Salvador
    Georgia
    Frankrike
    Den sentralafrikanske republikk
    Fransk Guyana
    Vanuatu
    Grønland
    India
    Hellas
    Djibouti
    Guyana
    Guatemala
    Indonesia
    Hviterussland
    Egypt
    Paraguay
    Haiti
    Irak
    Irland
    Ekvatorial-Guinea
    Peru
    Honduras
    Iran
    Island
    Elfenbenskysten
    Surinam
    Jamaica
    Israel
    Italia
    Eritrea
    Uruguay
    Mexico
    Japan
    Kroatia
    Eswatini
    Venezuela
    Nicaragua
    Jemen
    Kypros
    Etiopia
    Panama
    Jordan
    Latvia
    Gabon
    Puerto Rico
    Kambodsja
    Litauen
    Gambia
    USA
    Kasakhstan
    Luxemburg
    Ghana
    Kina
    Moldova
    Guinea
    Kirgisistan
    Montenegro
    Guinea-Bissau
    Kuwait
    Nederland
    Kamerun
    Laos
    Nord-Makedonia
    Kenya
    Libanon
    Norge
    Kongo
    Malaysia
    Østerrike
    Lesotho
    Mongolia
    Polen
    Liberia
    Myanmar (Burma)
    Portugal
    Libya
    Nepal
    Romania
    Madagaskar
    Nord-Korea
    Russland
    Malawi
    Oman
    Serbia
    Mali
    Pakistan
    Slovakia
    Marokko
    Palestina
    Slovenia
    Mauritania
    Qatar
    Spania
    Mosambik
    Saudi-Arabia
    Storbritannia
    Namibia
    Sør-Korea
    Svalbard og Jan Mayen
    Niger
    Sri Lanka
    Sveits
    Nigeria
    Syria
    Sverige
    Rwanda
    Tadsjikistan
    Tsjekkia
    Senegal
    Taiwan
    Tyskland
    Sierra Leone
    Thailand
    Ukraina
    Somalia
    Turkmenistan
    Ungarn
    Sør-Afrika
    Tyrkia
    Sør-Sudan
    Usbekistan
    Sudan
    Vietnam
    Tanzania
    Togo
    Tsjad
    Tunisia
    Uganda
    Vest-Sahara
    Zambia
    Zimbabwe