Model 5100A COLLECTanDRAIN - Auxiliary Drain with alarm, complete assembly

Model 5100A COLLECTanDRAIN - Auxiliary Drain with alarm, complete assembly

Improve your building's appearance, meet NFPA Code, and pro-actively deter improper maintenance and vandalism

Auxiliary drains often become targets for vandals, since most auxiliary drains do not provide standard protection against tampering. The COLLECTanDRAIN® M5100 and M5200 provide a consistent and clean appearance, and they feature our Patented Anti-Trip Plate that only allows one valve to be open at a time so sprinkler systems cannot be tripped by improper maintenance or vandalism.

The COLLECTanDRAIN® M5100 and M5200 both use the M5300 as the base of their design covered by our Patented Anti-Trip Plate. Our Anti-Trip Plates meet NFPA signage requirements and feature a signal red, powdercoat finish for added durability against weathering. The M5100 features a M5100ALBV Water Detector and Alarm that emits a visual and audible warning when the unit needs servicing.

Specifikation
  • SPRINKLER SPECIALTY PIPE FITTINGS
    Auxiliary Drain and Condensation Collecting Assemblies for Dry Pipe and Preaction Sprinkler Systems:

    1. Manufacturers:  Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
      1. AGF Manufacturing Inc.; Model 5100A COLLECTanDRAIN™.
      2. Insert manufacturer's name
    2. Standards:
      1. NFPA 13 & NFPA 25.
    3. Material:  Black Steel or Galvanized Pipe Auxiliary Drain with Anti-Trip Plate and Water Detector
    4. Components:
      1. 1 inch MIPT x FIPT Brass quarter turn ball valve with chrome plated ball.
      2. 1 inch MIPT x FIPT Ball Valve with Side Ports.
        1. Water Detection Alarm with Brass Nipple.
        2. Powered by a 9-volt battery to operate a red LED visual indicator and an over 92 dB beeping alarm which are activated when water is present in the COLLECTanDRAIN™.
        3. Battery operated system provides multiple years of service for intermittent alarming or can operate continuously for 72 hours. Unit will provide low battery power indication through audible chirp and yellow LED visual indicator.
        4. Device may be optionally hardwired to a 12 to 24 VDC power source.
        5. Unit features a test button to confirm operational integrity, offers left or right side installation, and can be isolated for service or battery replacement.
        6. Unit may be configured to alarm only when temperature is below 45°F or at any temperature.
        7. Device may be wired to provide remote notification with NO and NC terminals.
      3. Anti-Trip Plate (ATP):  Prevents the opening of either the upper or lower drain valve unless the opposite valve is in the correct closed position, preventing an accidental/malicious tripping of the alarm valve and filling of the sprinkler system.
        1. ATP is powder coated safety red for corrosion resistance and silk-screened with both “AUXILIARY DRAIN” and operating instructions.
        2. ATP can be locked to prevent tampering.
      4. Anti-Trip Plate Mounting Hardware Set.
      5. Two 1 inch by 2 inch (25 mm by 51 mm) Bell Reducer.
      6. 2 inch by 12 inch long (51 mm by 305 mm) Condensate Nipple.
      7. 1 inch (25 mm) Galvanized Square Head Plug.
Teknisk specifikation
  • Unik ref.agf-model-5100a
  • ProduktfamilieAGF Fire Sprinkler Products
  • ProduktgruppeCOLLECTanDRAIN
  • TypeObjekt (enkelt objekt)
  • Udgivelsesdato2019-10-18
  • Udgavenummer1
Relateret
  • Materiale primærtKulstofstål
  • Materiale sekundærtMessing
  • Designet iUSA
  • Fremstillet iUSA
Klassifikation
  • BIMobject-kategoriBrandprodukter - Sprinklersystemer
  • IFC-klassifikationVentil
  • UNSPSC-navnControl valves
  • UNSPSC-kode40141609
  • Uniclass 2015-kodePr_65_54_24
  • Uniclass 2015-beskrivelseDrainage valves
  • CSI MasterFormat 2014-kode23 09 13.33
  • CSI MasterFormat 2014-titelControl Valves
  • OmniClass-nummer23-27 31 00
  • OmniClass-betegnelseValves

Tilgængelighed i region

Asien Europa Afrika Sydamerika Oceanien Nordamerika
Afghanistan
Albanien
Ækvatorial Guinea
Argentina
Australien
Bahamas
Armenien
Belgien
Algeriet
Bolivia
Fiji
Belize
Aserbajdsjan
Bosnien-Herzegovina
Angola
Brasilien
New Zealand
Canada
Bangladesh
Bulgarien
Benin
Chile
Ny Kaledonien
Costa Rica
Bhutan
Cypern
Botswana
Colombia
Papua Ny Guinea
Cuba
Cambodia
Danmark
Burkina Faso
Ecuador
Solomon-øerne
Dominikanske Republik
Filippinerne
Estland
Burundi
Falkland-øerne (Islas Malvinas)
Timor-Leste
El Salvador
Forenede Arabiske Emirater
Finland
Cameroon
Fransk Guiana
Vanuatu
Grønland
Georgien
Frankrig
Chad
Guyana
Guatemala
Indien
Grækenland
Congo
Paraguay
Haiti
Indonesien
Holland
Den centralafrikanske republik
Peru
Honduras
Irak
Hviderusland
Den demokratiske republik Congo
Suriname
Jamaica
Iran
Irland
Djibouti
Uruguay
Mexico
Israel
Island
Egypten
Venezuela
Nicaragua
Japan
Italien
Elfenbenskysten
Panama
Jordan
Jan Mayen
Eritrea
Puerto Rico
Kazakhstan
Kroatien
Eswatini
USA
Kina
Letland
Etiopien
Kuwait
Litauen
Gabon
Kyrgyzstan
Luxembourg
Gambia
Laos
Moldova
Ghana
Libanon
Montenegro
Guinea
Malaysia
Nordmakedonien
Guinea-Bissau
Mongoliet
Norge
Kenya
Myanmar (Burma)
Østrig
Lesotho
Nepal
Polen
Liberia
Nordkorea
Portugal
Libyen
Oman
Rumænien
Madagascar
Pakistan
Rusland
Malawi
Palæstina
Schweiz
Mali
Qatar
Serbien
Marokko
Saudiarabien
Slovakiet
Mauritania
Sri Lanka
Slovenien
Mozambique
Sydkorea
Spanien
Namibia
Syrien
Storbritannien
Niger
Taiwan
Sverige
Nigeria
Tajikistan
Tjekkiet
Rwanda
Thailand
Tyskland
Senegal
Turkmenistan
Ukraine
Sierra Leone
Tyrkiet
Ungarn
Somalia
Uzbekistan
Sudan
Vietnam
Sydafrika
Yemen
Sydsudan
Tanzania
Togo
Tunesien
Uganda
Vestsahara
Zambia
Zimbabwe