    AGF's commercial RiserPACK Model 8611 is a riser manifold for NFPA 13 fire sprinkler systems and is designed to fit into a corner to minimize protruding and comply with ADA Standards. Model 8611 includes a flow switch, TESTanDRAIN Model 1011A with included pressure relief valve and trim, Model 7600 3-way universal gauge valve, and a Model 7500 pressure gauge. Available with a steel body in sizes 2"-6", orifice sizes 3/8" (K 2.8) - 25K, and a groove x groove connection. AGF's corner manifold is available with a right or left drain to accommodate every installation configuration.

    Specifikation
    • Model 8611 Commercial Corner RiserPACK

      1. 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:
        1. Product: Commercial Model M8611. Includes a flow switch, TESTanDRAIN Model 1011A, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge and a model M7000 Pressure Relief Valve.
          1. Riser Model: Pre-Assembled TESTanDRAIN Riser 2, 2-1/2, 3, 4, and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm):
            1. Inlet and Outlet (Schedule 10 steel): Grooved 2, 2-1/2, 3, 4 and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm) Models.
            2. Schedule 10 fabricated steel body with 3mil (.08 mm) powder coated red finish.
            3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
            4. Pressure Rating: 300 psig (2070 kPa).
            5. Size: Same as connected piping.

      ** NOTE TO SPECIFIER ** Delete valve not required.

      1. Valve Model 1011 TESTanDRAIN valve for a 2 inch (51 mm) Model:
        1. 1 inch (25 mm) FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      1. Valve Model 1011 TESTanDRAIN valve for a 4 or 6 inch (102 mm, 152 mm) Models:
        1. 2 inch FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 25.2K, as required by NFPA 13, latest edition.
      8. Water flow alarm switch.
      9. Pressure Gauge: AGF Model 7500.
      10. 1/4 inch, 3-way globe valve: AGF Model 7600
      11. Pressure Relief Valve and Drainage Piping: AGF Model 7000 or AGF Lockable Model 7000L

      ** NOTE TO SPECIFIER ** Delete pressure rating not required.

      1. Pressure Rating: Factory rated at 175 PSI.
      2. Pressure Rating: 200 PSI.
      3. Pressure Rating: 225 PSI.
      4. Pressure Rating: 300 PSI.
      5. Body Material: Bronze body and stainless steel spring.
      6. Components: Nylobraid flexible tube, Two 1/2 inch (13 mm) NPT by barbed 90 degree elbows, external identification plate and integral flushing handle to remove debris.
      7. 1/2 inch (13 mm) MIPT inlet, 1/2 inch (13 mm) FIPT outlet.
      8. Relief pressure shall be factory set to project specifications.
      9. Relief valve shall operate to the OPEN position between 90% and 105% of the set pressure.
      10. Relief valve shall reseat or CLOSE at a minimum of 80% of set pressure.
    Teknisk specifikation
    • Unik ref.AGF-Corner-Riser
    • ProduktfamilieAGF Fire Sprinkler Products
    • ProduktgruppeRiserPACK®
    • Udgivelsesdato2022-03-02
    • Udgavenummer1
    Relateret
    • Materiale primærtPulverbelagt stål
    • Designet iUSA
    • Fremstillet iUSA
    Klassifikation
    • BIMobject-kategoriBrandprodukter - Sprinklersystemer
    • CSI MasterFormat 2014-kode21 00 00
    • CSI MasterFormat 2014-titelFire Suppression
    • OmniClass-nummer23-29 33 00
    • OmniClass-betegnelseFire Suppression System Components
    • CSI UniFormat II-kodeD40
    • CSI UniFormat II-titelFIRE PROTECTION

    Tilgængelighed i region

    Asien Europa Afrika Sydamerika Oceanien Nordamerika
    Afghanistan
    Albanien
    Ækvatorial Guinea
    Argentina
    Australien
    Bahamas
    Armenien
    Belgien
    Algeriet
    Bolivia
    Fiji
    Belize
    Aserbajdsjan
    Bosnien-Herzegovina
    Angola
    Brasilien
    New Zealand
    Canada
    Bangladesh
    Bulgarien
    Benin
    Chile
    Ny Kaledonien
    Costa Rica
    Bhutan
    Cypern
    Botswana
    Colombia
    Papua Ny Guinea
    Cuba
    Cambodia
    Danmark
    Burkina Faso
    Ecuador
    Solomon-øerne
    Dominikanske Republik
    Filippinerne
    Estland
    Burundi
    Falkland-øerne (Islas Malvinas)
    Timor-Leste
    El Salvador
    Forenede Arabiske Emirater
    Finland
    Cameroon
    Fransk Guiana
    Vanuatu
    Grønland
    Georgien
    Frankrig
    Chad
    Guyana
    Guatemala
    Indien
    Grækenland
    Congo
    Paraguay
    Haiti
    Indonesien
    Holland
    Den centralafrikanske republik
    Peru
    Honduras
    Irak
    Hviderusland
    Den demokratiske republik Congo
    Suriname
    Jamaica
    Iran
    Irland
    Djibouti
    Uruguay
    Mexico
    Israel
    Island
    Egypten
    Venezuela
    Nicaragua
    Japan
    Italien
    Elfenbenskysten
    Panama
    Jordan
    Jan Mayen
    Eritrea
    Puerto Rico
    Kazakhstan
    Kroatien
    Eswatini
    USA
    Kina
    Letland
    Etiopien
    Kuwait
    Litauen
    Gabon
    Kyrgyzstan
    Luxembourg
    Gambia
    Laos
    Moldova
    Ghana
    Libanon
    Montenegro
    Guinea
    Malaysia
    Nordmakedonien
    Guinea-Bissau
    Mongoliet
    Norge
    Kenya
    Myanmar (Burma)
    Østrig
    Lesotho
    Nepal
    Polen
    Liberia
    Nordkorea
    Portugal
    Libyen
    Oman
    Rumænien
    Madagascar
    Pakistan
    Rusland
    Malawi
    Palæstina
    Schweiz
    Mali
    Qatar
    Serbien
    Marokko
    Saudiarabien
    Slovakiet
    Mauritania
    Sri Lanka
    Slovenien
    Mozambique
    Sydkorea
    Spanien
    Namibia
    Syrien
    Storbritannien
    Niger
    Taiwan
    Sverige
    Nigeria
    Tajikistan
    Tjekkiet
    Rwanda
    Thailand
    Tyskland
    Senegal
    Turkmenistan
    Ukraine
    Sierra Leone
    Tyrkiet
    Ungarn
    Somalia
    Uzbekistan
    Sudan
    Vietnam
    Sydafrika
    Yemen
    Sydsudan
    Tanzania
    Togo
    Tunesien
    Uganda
    Vestsahara
    Zambia
    Zimbabwe