FW-5050-DW Access Door Specifications:
Material: Steel or Stainless Steel
Door: 20 gauge, filled with 2" thick fire rated insulation, Mounting Frame: 16 gauge, flange to be drywall taping bead flange
Hinge: Concealed
Fire Rating: (Walls): UL — 1-1/2 hour "B" label. ULC — 2 hour "B" label. Max size: 36 x 48. (Ceilings): Warnock Hersey International 3 hour rated in a non-combustible ceiling. 1 hour rated in a combustible ceiling. Max size: 24 x 36
Standard Latch: Universal self-latching bolt, operated by either a knurled knob or flush key. Doors can be prepared for mortise cylinder locks (Master Keying).
Finish: Steel: 5 stage iron phosphate preparation with prime coat of white baked-on enamel. Stainless Steel: #4 satin polish