发布您的产品
CLOVER 125

CLOVER 125

High power condensing thermal module with large water content. Designed for single or cascade installations, in combination with all model of CLOVER series up to 960 kW. Complete range of hydro, gas and flue gas accessories for the sequence installation. Max output power in heating mode (50/30°C) 125,0 kW NOx class 6° Water volume 265 liters Max operated pressure 6 bar
规格
  • - High power condensing thermal module with large water content. Designed for single or cascade installations, in combination with all model of CLOVER series up to 960 kW. Complete range of hydro, gas and flue gas accessories for the sequence installation. - Flue gas pipe heat exchanger, made of AISI 316 Ti stainless steel, with vertical configuration, with helical cross-section - Combustion unit with class 6 emissions according to EN 15502-1. The modules can run on Natural gas and LPG - Generator protection systems: System double sensor (delivery and return) for operation at constant ΔT Flue gas safety sensor Water pressure switch with minimum threshold at 0.8 bar - Air / Flue gas circuit with suction in the installation site and check valve integrated on the extraction unit to size the pressurised flue gas manifold - Four heavy-duty floating wheels fitted as per standard to facilitate discharge and mobility inside the thermal power plant. Positioning feet integrated in the wheel unit - It reaches one of the highest seasonal space heating efficiencies in its category: ηs 94%. Combined with the modulating remote control and the outdoor probe (optional) it reaches the top efficiency class A+ - The high-water volume of the generator allows the boiler to be connected to the system without the need for separating devices and allows for a very high design Δt - Management of the modules in bank set-up with self-configuring MASTER / SLAVE system - Generator on and off setting (which can be switched on and off in sequence or work simultaneously in parallel) through the control panel of the MASTER generator - Electronics on board the machine to manage a system with two direct zones and one DHW storage tank or systems with differentiated temperatures (direct and mixed) in combination with the with system manager THETA+ - RANGE RATED certified generator to adjust the generated power to the system’s needs by increasing the efficiency of the system and preserving the mechanics of the machine - The modules can be controlled and operated remotely: Regulation of power or temperature with 0 - 10V signal Signalling of block alarm for safety and to resume operation OPENTHERM (OT) and MODBUS parameterisable communication protocols - Electronic control of microprocessor combustion allows 1/5 modulation on the single generator and 1/15 modulation for the maximum configuration (3 x 320 modules in bank set-up)
技术规格
  • 唯一参考CLOVER125
  • 产品系列HVAC - Boilers
  • 产品组Boilers
  • 类型对象(单个对象)
  • 发布日期2022-06-09
  • 版本号1
  • 高度 (mm)1905
  • 宽度 (mm)660
  • 深度 (mm)935
相关
  • 主材料金属
  • 次要材料塑料
  • 设计国家/地区Italy
  • 制造国家/地区Italy
  • 净重 (Kg)280
分类
  • BIMobject 类别暖通空调 - 锅炉
  • IFC 分类锅炉
  • OmniClass 编号23-33 11 22
  • OmniClass 标题Electric Boilers

发售地区

Europe Asia North America Africa South America
Åland Islands
Afghanistan
Anguilla
Algeria
Argentina
Albania
Armenia
Antigua and Barbuda
Angola
Bolivia
Andorra
Azerbaijan
Aruba
Benin
Brazil
Austria
Bahrain
Barbados
Botswana
Chile
Belarus
Bangladesh
Belize
Burkina Faso
Colombia
Belgium
Bhutan
Bermuda
Burundi
Ecuador
Bosnia and Herzegovina
British Indian Ocean Territory
British Virgin Islands
Cameroon
Falkland Islands (Islas Malvinas)
Bulgaria
Brunei
Canada
Cape Verde
French Guiana
Croatia
Cambodia
Caribbean Netherlands
Central African Republic
Guyana
Cyprus
China
Cayman Islands
Chad
Paraguay
Czech Republic
Christmas Island
Collectivity of Saint Martin
Comoros
Peru
Denmark
Cocos (Keeling) Islands
Costa Rica
Côte d'Ivoire
Suriname
Estonia
Georgia
Cuba
Democratic Republic of the Congo
Uruguay
Faroe Islands
Hong Kong
Curaçao
Djibouti
Venezuela
Finland
India
Dominica
Egypt
France
Indonesia
Dominican Republic
Equatorial Guinea
Germany
Iran
El Salvador
Eritrea
Gibraltar
Iraq
Greenland
Eswatini
Greece
Israel
Grenada
Ethiopia
Guernsey
Japan
Guadeloupe
Gabon
Hungary
Jordan
Guatemala
Ghana
Iceland
Kazakhstan
Haiti
Guinea
Ireland
Kuwait
Honduras
Guinea-Bissau
Isle of Man
Kyrgyzstan
Jamaica
Kenya
Italy
Laos
Martinique
Lesotho
Jersey
Lebanon
Mexico
Liberia
Latvia
Macau
Montserrat
Libya
Liechtenstein
Malaysia
Nicaragua
Madagascar
Lithuania
Maldives
Panama
Malawi
Luxembourg
Mongolia
Puerto Rico
Mali
Malta
Myanmar (Burma)
Saint Kitts and Nevis
Mauritania
Moldova
Nepal
Saint Lucia
Mauritius
Monaco
North Korea
Saint Pierre and Miquelon
Mayotte
Montenegro
Oman
Saint Vincent and the Grenadines
Morocco
Netherlands
Pakistan
Saint-Barthélemy
Mozambique
North Macedonia
Palestine
Sint Maarten
Namibia
Norway
Philippines
The Bahamas
Niger
Poland
Qatar
Trinidad and Tobago
Nigeria
Portugal
Saudi Arabia
Turks and Caicos Islands
Republic of the Congo
Romania
Singapore
U.S. Virgin Islands
Reunion
Russia
South Korea
United States
Rwanda
San Marino
Sri Lanka
Saint Helena
Serbia
Syria
São Tomé and Príncipe
Slovakia
Taiwan
Senegal
Slovenia
Tajikistan
Seychelles
Spain
Thailand
Sierra Leone
Svalbard and Jan Mayen
Türkiye
Somalia
Sweden
Turkmenistan
South Africa
Switzerland
United Arab Emirates
South Sudan
Ukraine
Uzbekistan
Sudan
United Kingdom
Vietnam
Tanzania
Vatican City
Yemen
The Gambia
Togo
Tunisia
Uganda
Western Sahara
Zambia
Zimbabwe