Bitumen 1 layer membrane system on a non-exposed roof with a concrete substrate insulated with EPS and mineral wool.
---------- Recommended Product Configuration ---------
1 - Concrete Substrate - Thickness - 200.0mm - Depending on Construction
2 - Vapour Barrier - Dampsperre X20 - Thickness - 0.2mm
3 - EPS - Thickness - 270.0mm
4 - Mineral Wool - Thickness - 30.0mm
5 - Bitumen - Icopal Mono PC - Thickness - 4.2mm