TED50GS (GENSET) Damper
Ruskin

TED50GS (GENSET) Damper

Thermally Efficient Extruded Aluminum Insulated Airfoil Blade Damper AMCA Class IA Leakage Rated (GENSET)

The TED50GS is designed to provide maximum combustion air and pressure reliefquickly for emergency generator start up to avoid damage of equipment or surrounding space. The factory mounted fast-acting 8-second spring open actuator provides optimal performance and reliability. The TED50GS also provides AMCA class 1A leakage rating of 3cfm/ft2 at 1” w.g. when blades are closed to meet requirements of the International Energy Conservation Code (IECC).

Specifikation
  • Furnish and install, where shown on plans and/or as indicated in schedules thermally efficient control dampers meeting the following minimum specifications. Damper shall be Ruskin TED50GS. Damper frame shall be constructed of 6063T6 high yield extruded aluminum with a minimum wall thickness of .07” (2) and a yield stress of no less than 30,000psi. Low pressure drop aerodynamically shaped blades shall be constructed of 6063T6 high yield extruded aluminum with a minimum wall thickness of .07 (2) and a yield stress of no less than 30,000psi. Blades shall be filled with Polyurethane structural foam with a minimum density of 15 pcf. Insulated blades shall include a thermal break positioned between two blade seals to completely eliminate a thermal path from one side of the damper to the other. Thermal breaks on the blade edges shall not be visible when the damper is in the closed position. Damper assembly shall have a symmetrical design to ensure the resistance to airflow is identical from either direction. Axles shall be 1/2” (13) hexagonal plated steel material. Stainless steel axles shall be utilized when noted on the plans. Polycarbonate bearings shall be formed to the shape of the axle to reduce leakage through the frame. Bearings shall rotate inside an Acetal Copolymer outer bearing surface to reduce torque and promote a smooth operation throughout the stroke of the damper. Zero tolerance Swedgelock™ linkage arms shall be permanently and mechanically secured to each axle, eliminating future need for field adjustment of the linkage assembly. Linkage assembly shall be set to predetermined parameters ensuring leakage performance for the life of the product. Linkage shall be completely concealed within the damper frame, out of the airstream. Stainless steel linkage of the same design shall be used when specified on the plans. Blade edge seals shall be extruded Santoprene™ and shall be mechanically fastened to the blades. Jamb seals shall be low profile, light prohibiting, extruded Santoprene™ secured in extruded pockets of the damper frame. Stainless steel jamb seals creating a thermal path from one side of the blade to the other are not permitted. Damper shall be suitable for pressures up to 6 inches water gage (1.5kPa), velocities up to 4,000 fpm (20.3 m/s), standard air leakage of less than 8 cfm/ft2  at 4 inches water gage (2.44 cmm/m2  at 1 kPa), temperature range of -45°F to 185°F (-43°C to 85°C) and an R value no less than 2.16. All performance data shall be submitted to engineer of record for approval. Damper leakage, performance shall be in accordance with the latest edition of AMCA 500-D, and shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. Damper widths from 12” to 48” (305 to 1219) wide shall not leak any greater than 3 cfm/sq.ft. at 1” w.g. (15.2 l/s-m2  at .25 kPa). Damper shall be factory equipped with fast acting 8-second spring return electric actuator with 40,000 open/closed cycle testing and shall be equivalent in all respects to Ruskin Model TED50GS.

Teknisk specifikation
  • Unik ref.TED50GS
  • ProduktfamiljDampers for Air Ductwork
  • ProduktgruppCommercial Control Dampers
  • TypObjekt (enstaka objekt)
  • Publiceringsdatum2022-07-29
  • Edition nummer1
Relaterad
  • HuvudmaterialExtruded Aluminum
  • Designad iUSA
  • Tillverkad iUSA
Klassificering
  • BIMobjektkategoriVVS - Kanalsystem
  • IFC klassificeringSpjäll
  • UNSPSC namnVentilation dampers
  • UNSPSC kod40101504
  • Uniclass 2015 kodPr_65_65_24
  • Uniclass 2015 beskrivningDuct dampers
  • CSI MasterFormat 2014 Kod23 09 13.43
  • CSI MasterFormat 2014 TitelControl Dampers
  • OmniClass nummer23-33 29 00
  • OmniClass TitelHVAC Dampers
  • CSI UniFormat II KodD3090
  • CSI UniFormat II TitelOther HVAC Systems & Equipment

Region tillgänglighet

Europa Asien Nordamerika Afrika Sydamerika Oceanien
Åland
Afghanistan
Amerikanska Jungruöarna
Algeriet
Argentina
Amerikanska Samoaöarna
Albanien
Armenien
Anguilla
Angola
Bolivia
Australien
Andorra
Azerbajdzjan
Antigua och Barbuda
Benin
Brasilien
Cooköarna
Belgien
Bahrain
Aruba
Botswana
Chile
Fiji
Bosnien och Hercegovina
Bangladesh
Bahamas
Burkina Faso
Colombia
Franska Polynesien
Bulgarien
Bhutan
Barbados
Burundi
Ecuador
Guam
Cypern
Brittiska territoriet i Indiska oceanen
Belize
Centralafrikanska republiken
Falklandsöarna (Islas Malvinas)
Kiribati
Danmark
Brunei
Bermuda
Demokratiska republiken Kongo
Franska Guyana
Marshallöarna
Estland
Filippinerna
British Virgin Islands
Djibouti
Guyana
Mikronesiens federerade stater
Färöarna
Förenade Arabemiraten
Caymanöarna
Egypten
Paraguay
Nauru
Finland
Georgia
Costa Rica
Ekvatorialguinea
Peru
Niue
Frankrike
Hongkong
Curaçao
Elfenbenskusten
Surinam
Nordmarianerna
Gibraltar
Indien
Dominica
Eritrea
Uruguay
Norfolk Island
Grekland
Indonesien
Dominikanska republiken
Etiopien
Venezuela
Nya Kaledonien
Guernsey
Irak
El Salvador
Gabon
Nya Zeeland
Irland
Iran
Grenada
Gambia
Östtimor
Island
Israel
Grönland
Ghana
Palau
Isle of Man
Japan
Guadeloupe
Guinea
Papua Nya Guinea
Italien
Jordanien
Guatemala
Guinea-Bissau
Pitcairn Islands
Jersey
Julöarna
Haiti
Jamhuri ya Uganda
Samoa
Kroatien
Kambodja
Honduras
Kamerun
Solomon Islands
Lettland
Kazakstan
Jamaica
Kap Verde
Tokelauöarna
Liechtenstein
Kina
Kanada
Kenya
Tonga
Litauen
Kokosöarna
Karibiska Nederländerna
Komorerna
Tuvalu
Luxemburg
Kuwait
Kuba
Kongo
United States Minor Outlying Islands
Malta
Kyrgyzstan
Martinique
Lesotho
Vanuatu
Moldavien
Laos
Mexiko
Liberia
Wallis- och Futunaöarna
Monaco
Libanon
Montserrat
Libyen
Montenegro
Macao
Nicaragua
Madagaskar
Nederländerna
Malaysia
Panama
Malawi
Nordmakedonien
Maldiverna
Puerto Rico
Mali
Norge
Mongoliet
Saint Christopher och Nevis
Marocko
Österrike
Myanmar (Burma)
Saint Lucia
Mauretanien
Polen
Nepal
Saint Vincent och Grenadinerna
Mauritius
Portugal
Nordkorea
Saint-Barthélemy
Mayotte
Rumänien
Oman
Saint-Martin
Moçambique
Ryssland
Pakistan
Saint-Pierre-et-Miquelon
Namibia
San Marino
Palestina
Sint Maarten
Niger
Schweiz
Qatar
Trinidad och Tobago
Nigeria
Serbien
Saudiarabien
Turks och Caicos Islands
Réunion
Slovakien
Singapore
USA
Rwanda
Slovenien
Sri Lanka
Saint Helena
Spanien
Sydkorea
São Tomé och Príncipe
Storbritannien
Syrien
Senegal
Svalbard
Tadzjikistan
Seychellerna
Sverige
Taiwan
Sierra Leone
Tjeckien
Thailand
Södra Sudan
Tyskland
Turkiet
Somalia
Ukraina
Turkmenistan
Sudan
Ungern
Uzbekistan
Swaziland
Vatikanstaten
Vietnam
Sydafrika
Vitryssland
Yemen
Tanzania
Tchad
Togo
Tunisien
Västsahara
Zambia
Zimbabwe