Wilshire Planters, GFRC with Greenscreen Trellis
Wilshire Planters, GFRC with Greenscreen Trellis
    Tournesol

    Wilshire Planters, GFRC with Greenscreen Trellis

    2.8 av 5 stjärnor2.8(6 omdömen)

    Wilshire Planters, GFRC with Greenscreen® trellis

    An attractive, easy-to-install solution for creating privacy or hiding unattractive elements like building systems. Lightweight GFRC concrete planter (available in colors and textures), and Greenscreen® trellis, framed on top and sides, with vertical supports to fit in planter lip. Trellis is available in various powder-coat colors.

    • Durable, lightweight GFRC planter with powder-coated Greenscreen® trellis. 2”W x 2”L x 3”D grid.
    • Trellis vertical supports fit into planter lip and are secured with discrete stainless-steel fasteners.
    • Trellis is framed on top and sides and extends to planter edge so adjacent planters form a seamless trellis wall.
    • Select a Greenscreen® Trellis color in addition to a GFRC color and texture. Standard drain holes included.

    As a product manufacturer, Greenscreen supports the commitment and vision of design professionals to incorporate low-impact, environmentally sensitive building practices and promote sustainable design principles by providing critical reviews of credit contributions to the LEED and SITES™ programs including a downloadable Recycled Content Declaration.

    Specifikation
    • G U I D E S P E C I F I C A T I O N
      Guide Specification 32 94 50 – 5 [WELDED WIRE PANEL
      Greenscreen PLANT SUPPORT SYSTEM]
      PART 2 - PRODUCTS
      2.1 SUSTAINABILITY CHARACTERISTICS
      A. The welded wire panel plant support system and accessories shall have completed an ISO
      Compliant 14040/44, third party verified Life Cycle Assessment (LCA).
      2.2 ACCEPTABLE MANUFACTURER
      A. Greenscreen, 725 S. Figueroa St. Suite 1825, Los Angeles, CA 90017; Tel: 1-800-450-3494;
      sales@greenscreen.com, www.greenscreen.com.
      2.3 PANELS
      A. Panels shall be rigid, three dimensional welded wire grid fabricated of 14 gage galvanized steel
      wire.
      1. Metallic-Coated Steel Wire: Welded-wire, galvanized in accordance with ASTM A641.
      B. Face Grid: Wires shall be welded at each intersection to form a 2 x 2 inch face grid on the front
      and back of panels,
      C. Trusses: Face grids shall be separated by bent wire trusses spaced at 2-inch centers and welded
      to front and back face grids at each truss apex.
      D. Thickness: [3 inches.] [As shown on Drawings.]
      E. Length and Width: As indicated on the Drawings.
      F. Tolerance: 1/8 inch in width and 1/8 inch in length.
      2.4 ACCESSORIES
      A. Trim:
      1. Fabricate from 20-gage ASTM A879 galvanized steel.
      2. Types:
      a. Channel Trim: Thickness of panel x ½ inch legs.
      b. Angle Trim: ½ inch x ½ inch legs.
      3. Locations:
      a. As indicated on the Drawings.
      B. Clips and Straps: Provide manufacturer’s standard types of clips and straps suitable for mounting
      conditions. Fabricate from ASTM A879 galvanized steel. Adjustable clips shall have ¼ inch
      diameter 18-8 stainless steel bolt, washer, and nut.
      G U I D E S P E C I F I C A T I O N
      Guide Specification 32 94 50 – 6 [WELDED WIRE PANEL
      Greenscreen PLANT SUPPORT SYSTEM]
      C. Plastic Spacers: Provide ½ inch thick black Ultra High Molecular Weight polyethylene (UHMW)
      washers [to hold clips away from mounting surface].
      D. Fence Posts: 3-inch [2-7/8” OD ASTM A500] [square ASTM A500, Grade B] steel tube. The
      steel strip used in the manufacture of the post shall conform to ASTM A1011. Minimum yield
      strength shall be 45,000 psi. [Provide steel post caps.] Overall post length shall be as indicated
      on the Drawings.
      E. Fasteners for Mounting Clips to Fence Posts: Self drilling, self tapping hex washer head screws,
      with strength of Type 410 stainless steel, and corrosion resistance of Type 304 stainless steel.
      F. Fasteners for Attachment to Structure Pull Out Value:
      1. To Concrete or Masonry: [480 lbs.].
      2. To Structural Steel: [480 lbs.].
      3. To Light-Gage Steel Framing: [480 lbs.].
      4. To Wood Framing: [480 lbs.].
      G. Planter: [__________________________________________.]
      2.5 FABRICATION
      A. Cut to size.
      B. Weld trim to panels and grind smooth exterior surfaces of welds.
      C. Curved Panels: All curved panels shall be fabricated in the factory using approved “Cut-to-
      Curve” or “Crimped-to-Curve” procedures as recommended by manufacturer for diameter of
      curve and conditions of use prior to application of powder coat finish to ensure that all wire edges
      are coated and protected. The use of “Cut-to-Curve” or “Crimped-to-Curve” fabrication technique
      is dependent on the specific radius and the direction of the curve relative to the flat panel layout.
      2.6 FINISH
      A. Metal components (except fasteners) shall receive commercial grade finish system after
      fabrication.
      B. Finish System:
      1. Pretreat with general purpose, alkaline, water based cleaner / degreaser applied at 240
      degrees F.
      2. Prime with fusion bond epoxy powder coat.
      3. Topcoat with [TGIC] polyester or polyester-urethane powder coat with a minimum total
      dry film thickness of not less than [6 mils (0.15 mm)].
      G U I D E S P E C I F I C A T I O N
      Guide Specification 32 94 50 – 7 [WELDED WIRE PANEL
      Greenscreen PLANT SUPPORT SYSTEM]
      C. Salt Spray Resistance: Finish shall remain rust free when tested 1680 hours in accordance with
      ASTM B117.
      D. Finish and Color: [Textured Green.] [Textured Black.] [Silver.] [Bronze.] [Terra] [Gloss
      White.] [Color selected by [Architect] from manufacturer’s standards.] [RAL [Classic]
      [Design] color [__________].] [Custom color to match [__________].]
      E. Touch-Up Paint: Provide high quality, exterior-grade spray paint suitable for conditions of use.
      2.7 WARRANTY
      A. Standard 1 year warranty is available from the date of substantial completion or 18 months from
      the date of shipment, whichever comes first. Greenscreen warrants against defects in
      workmanship and materials that would result in failure under intended application and use as
      exterior fabricated wall grillage. “Failure” is defined as structural failure of the wire of sufficient
      incidents in any panel that would result in the panel not performing in a structural or safe manner
      under the intended application and use. Installation is excluded. Contact Greenscreen for further
      information, and extensions.
      2.8 MISCELLANEOUS MATERIALS
      A. Concrete: Refer to Section 03 30 00, CAST-IN-PLACE CONCRETE.
      B. Concrete: Normal-weight, air-entrained, ready-mix concrete with a minimum 28-day
      compressive strength of 3000 psi (20 MPa), 3-inch (75-mm) slump, and 1-inch (25-mm)
      maximum aggregate size [ or dry, packaged, normal-weight concrete mix complying with
      ASTM C 387 mixed with potable water according to manufacturer's written instructions].

    Teknisk specifikation
    • Unik ref.wilshire-planters-gfrc-with-greenscreen-trellis
    • ProduktfamiljWilshire Collection
    • ProduktgruppPlanters with Trellis
    • Publiceringsdatum2023-11-22
    • Edition nummer1
    Relaterad
    • Designad iUSA
    • Tillverkad iUSA
    Klassificering
    • BIMobjektkategoriLandskapsarkitektur - Annat
    • OmniClass nummer23-11 27 13 17
    • OmniClass TitelPlanters

    Region tillgänglighet

    Europa Nordamerika Asien Sydamerika
    Åland
    Amerikanska Jungruöarna
    Armenien
    Argentina
    Albanien
    Anguilla
    Azerbajdzjan
    Bolivia
    Andorra
    Antigua och Barbuda
    Bangladesh
    Brasilien
    Belgien
    Aruba
    Bhutan
    Chile
    Bosnien och Hercegovina
    Bahamas
    Brittiska territoriet i Indiska oceanen
    Colombia
    Bulgarien
    Barbados
    Brunei
    Ecuador
    Cypern
    Belize
    Filippinerna
    Falklandsöarna (Islas Malvinas)
    Danmark
    Bermuda
    Georgia
    Franska Guyana
    Estland
    British Virgin Islands
    Hongkong
    Guyana
    Färöarna
    Caymanöarna
    Indien
    Paraguay
    Finland
    Costa Rica
    Indonesien
    Peru
    Frankrike
    Curaçao
    Japan
    Surinam
    Gibraltar
    Dominica
    Julöarna
    Uruguay
    Grekland
    Dominikanska republiken
    Kambodja
    Venezuela
    Guernsey
    El Salvador
    Kazakstan
    Irland
    Grenada
    Kina
    Island
    Grönland
    Kokosöarna
    Isle of Man
    Guadeloupe
    Kyrgyzstan
    Italien
    Guatemala
    Laos
    Jersey
    Haiti
    Macao
    Kroatien
    Honduras
    Malaysia
    Lettland
    Jamaica
    Maldiverna
    Liechtenstein
    Kanada
    Mongoliet
    Litauen
    Karibiska Nederländerna
    Myanmar (Burma)
    Luxemburg
    Kuba
    Nepal
    Malta
    Martinique
    Nordkorea
    Moldavien
    Mexiko
    Pakistan
    Monaco
    Montserrat
    Singapore
    Montenegro
    Nicaragua
    Sri Lanka
    Nederländerna
    Panama
    Sydkorea
    Nordmakedonien
    Puerto Rico
    Tadzjikistan
    Norge
    Saint Christopher och Nevis
    Taiwan
    Österrike
    Saint Lucia
    Thailand
    Polen
    Saint Vincent och Grenadinerna
    Turkmenistan
    Portugal
    Saint-Barthélemy
    Uzbekistan
    Rumänien
    Saint-Martin
    Vietnam
    Ryssland
    Saint-Pierre-et-Miquelon
    San Marino
    Sint Maarten
    Schweiz
    Trinidad och Tobago
    Serbien
    Turks och Caicos Islands
    Slovakien
    USA
    Slovenien
    Spanien
    Storbritannien
    Svalbard
    Sverige
    Tjeckien
    Tyskland
    Ukraina
    Ungern
    Vatikanstaten
    Vitryssland