Tornado
Tornado
    Arjo

    Tornado

    Tornado® Flusher Disinfector, Bedpanwasher Tornado is a high-powered flusher-disinfector with a wide range of standard and optional features to meet your infection control needs. Tornado’s automated operation features are designed to help reduce the risk of cross-contamination while delivering highly effective cleaning and disinfection results. Support touch-free operation routines with an optional IR sensor or foot pedal to open the door. The disinfection phase can be controlled by time and temperature, or by the chosen A₀ value, while the Pipe System Disinfection (PSD) feature disinfects the entire pipe and nozzle system at the end of each cycle. Tornado also offers the option to record or track disinfection records via printer or USB, and consumes exceptionally low amounts of water, energy and chemicals per cycle**, thereby reducing operating costs as well as the overall impact on the environment.
    Specifikation
    • “Equipment specifically built to empty, wash, rinse, thermally disinfect and cool bedpans and urinals                                                                                                                                                                                                                                                                                                                                                 The Tornado™ system comprises of a series of high pressure water cycles delivered through strategically located fixed and rotating nozzles, followed by a steam phase. 

      Key features
      Easy to use - simply load, close and activate programme.
      A flexible design - choice of polymeric material or stainless steel for outer casing.
      9+2 - system includes nine fixed and two rotating nozzles to meet the highest cleaning requirements.
      Pipe System Disinfection (PSD) provides rapid disinfection through all fixed and rotating nozzles, disinfecting the entire pipe and nozzle system with every cycle.
      Smooth, hygienic chamber means no folds or pockets.
      Safe and rapid thermal disinfection of the goods with the steam transported into the chamber through all pipes and nozzles.
      Meets and exceeds the stringent cleaning and disinfection requirements of EN ISO15883 (CAN/CSA Z15883).
      Drying/cooling fan for rapid and hygienic dry and cooling of recepticles with HEPA filtered (H13) air.
      Deep-drawn stainless steel chamber without welded joints.
      Read out display provides the user with all information needed for operation and control.
      Remaining time displayed in an easy-to-follow cycle sequence.
      Ao value and control.
      Three programmes available: economy, normal and intensive, with 22 additional programmes available upon request.
      Optional automatic door function.
      Locking system during cycle, securing staff safety and ensuring a complete cleaning and disinfection process.
      Optional process records, via printer or USB.
      Environmentally friendly - low consumption of water and energy, recyclable material.
      Wide range of holders available for different receptacles.
      Lockable storage for detergent containers.
      Easy maintenance and service.“”
       

      Tornado - TECHNICAL DATA          
      UTILITY REQUIREMENTS          
      Utility Unit connection Supply Pressure requirements   Flow
      requirements   Comments  
      Cold Water (CW)   15 mm (G1/2") 100-800 kPa (1-8 bar, 14-116 PSi)   20 L/min   See notes 1 and 3 
      Hot Water (HW)  15 mm (G1/2")  100-800 kPa (1-8 bar, 14-116 PSi)    20 L/min    See notes 2 and 3 
      Drain (D)    Ø90 alt. Ø 110mm Not Applicable  Peak 1 L/sec  See notes 3 and 4
      Electrical (equipped with internal steam generator)           
      Voltage    Recommended service disconnect       Full load, Amps    See notes 5 and 6 
      L1, 230 VAC, 1N+PE, 50 Hz     Max. 3,0 kW, 1x Fuse C 16 A     13 A   
       L2, 230VAC, 3+PE, 50Hz     Max. 3,75 kW, 3x Fuse C 16 A     12 A   
        L3, 380-400VAC, 3N+PE, 50 HzA     Max. 3,75 kW, 3x Fuse C 10     9 A    
       L5, 240 VAC, 2+PE, 60 Hz     Max .3,3 kW, 2 x Fuse C 15 A     15 A    
       L6, 240VAC, 3+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 15 A    13 A   
       L9, 208 VAC, 2+PE, 60 Hz     Max. 3,0 kW, 2x Fuse C 15 A     14 A   
       L10, 208VAC, 3+PE, 60 Hz     Max. 3,75 kW, 3x Fuse C 15 A     13 A   
       L14, 200 VAC, 2+PE, 50 Hz      Max .3,0 kW, 2x Fuse C 16 A    15 A   
       L15, 200VAC, 3+PE, 50 Hz      Max. 3,75 kW, 3 x Fuse C 16 A    14 A   
       L18, 200 VAC, 2+PE, 60 Hz      Max. 3,0 kW, 2x Fuse C 16 A    15 A   
       L19, 200VAC, 3+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 16 A    15 A   
       L22, 230 VAC, 1N+PE, 60 Hz     Max. 3,0 kW, 1x Fuse C 16 A     13 A   
       L24, 380-400VAC, 3N+PE, 60 Hz      Max. 3,75 kW, 3x Fuse C 10 A    10 A   
       L28, 240 VAC, 1N+PE, 50 Hz      Max. 3,3 kW, 1x Fuse C 16 A    13,6 A   
       L30, 415VAC, 3N+PE, 50 Hz     Max. 3,75 kW, 3x Fuse C 10 A     9 A   
       OPERATING CONDITIONS       
       Room temperature     5-40°C (41-104F)       
       Air humidity     < 80% at 31°C (87° F)       
       Max surface temperature    40° C (104°F)       
      Water consumption          
       Economy program    11 liter ± 10 %*     
       * if option cooling/drying fan is selected for the cooling phase. If internal cooling is selected, additionally 3 liters ± 1 liter will be added to the stated consumption.

       Normal program    18 liter ± 10 %*  
       Intensive program    25 liter ± 10 %*  
      Chamber size and volume          
      Stainless steel 565x410x290, 67 liter          
      Noise level          
      Octave band(Hz)      

       125  250  500 1000   2000  4000  8000  LwA  LwAFmax The sound power level as
      linear octave band levels are
      presented as A-leveled sound
      power level, both LwA and
      LwAFmax. 
      Correction (Kok)      57  61 58  55    53 48    47  61  75
      Estimated LpA levels for Tornado located in a 70 m³ room, db ref 20 μPa.          
      Type of room     Description    Operator location *    3 m from washer  The calculated sound power
      levels are different LpA levels in
      different types of rooms. With
      bigger room volume the noise
      level is reduced and vice versa.
      Here are three examples of
      expected LpA levels.
      * See Note 7       
      Hard     All walls from concrete etc no
      absorbing elements.    60   60 
      Normal    Some sound
      absorbing elements
      like furniture and
      textiles.     56   55 
      Subdued    Some absorbing
      elements in ceiling
      and textiles.    53   51  
      Outer dimensions          
         Freestanding         See installation drawing in subsection
      installation.
              
       Width    450 mm (17" 11/16)      
       Depth    580 mm (22" 3/4)      
       Height    1320 mm (51" 7/8)      
       Weight    100 kg/220 lb       
      Notes

      1) Cold water recommended quality = potable water accordingly to WHO guidelines, temp. <20°C (<68°F).

      2) Hot water recommended quality = potable water accordingly to WHO guidelines, temp. 45-60°C (113-140°F).

      3) It shall be the Customers responsibility to eliminate water hammer conditions if they occur in the service piping.

      4) It shall be the Customers responsibility to provide a properly sixed and located drainage system in accordance with the national

      plumbing code. Consider that other equipment is tied to drain to eliminate slow drainage or backup.

      5) It shall be the Customers responsibility to complete all electrical connections using properly sized wiring in accordance with the

      national electrical code.

      6) It shall be the Customers responsibility to install an approved a fused disconnect switch accordingly to national code in all electrical

      supply lines at the washer disinfector location.

      7) LpA levels are measured to EN ISO 3747:2000, 1 meter in front of the washer and 1,5 meter above the floor level.

      Systems Available
      Freestanding with or without automatic door. 
      Accessories
      Arjo bedpan with lid.
      Drainage floor, Ø 3 ½ and Ø 4 1/4" (90 and 110 mm).
      Drainage wall, , Ø 3 ½ and Ø 4 1/4" (90 and 110 mm).
      Valves and filter.
      Arjo Clean Flusher Detergent, 5L canister.
      Arjo Clean Flusher Rinse, 5L canister.“”                                                      ”

    Teknisk specifikation
    • Unik ref.Tornado
    • ProduktfamiljBed pan washer
    • ProduktgruppDisinfection
    • TypObjekt (enstaka objekt)
    • Publiceringsdatum2019-11-01
    • Edition nummer1
    • Höjd (mm)1320
    • Bredd (mm)580
    • Djup (mm)450
    Relaterad
    • HuvudmaterialRostfritt stål
    • Sekundärt materialPolymer
    • Designad iSverige
    • Tillverkad iPolen
    • Vikt netto (kg)100
    Klassificering
    • BIMobjektkategoriHälsovård - medicinsk
    • IFC klassificeringMöbler
    • UNSPSC namnFurniture and Furnishings
    • UNSPSC kod56
    • CSI MasterFormat 2014 Kod12 54 00
    • CSI MasterFormat 2014 TitelHospitality Furniture
    • OmniClass nummer23-21 11 00
    • OmniClass TitelCommercial Furniture

    Region tillgänglighet

    Europa Asien Nordamerika Afrika Sydamerika Oceanien
    Åland
    Afghanistan
    Amerikanska Jungruöarna
    Algeriet
    Argentina
    Amerikanska Samoaöarna
    Albanien
    Armenien
    Anguilla
    Angola
    Bolivia
    Australien
    Andorra
    Azerbajdzjan
    Antigua och Barbuda
    Benin
    Brasilien
    Cooköarna
    Belgien
    Bahrain
    Aruba
    Botswana
    Chile
    Fiji
    Bosnien och Hercegovina
    Bangladesh
    Bahamas
    Burkina Faso
    Colombia
    Franska Polynesien
    Bulgarien
    Bhutan
    Barbados
    Burundi
    Ecuador
    Guam
    Cypern
    Brittiska territoriet i Indiska oceanen
    Belize
    Centralafrikanska republiken
    Falklandsöarna (Islas Malvinas)
    Kiribati
    Danmark
    Brunei
    Bermuda
    Demokratiska republiken Kongo
    Franska Guyana
    Marshallöarna
    Estland
    Filippinerna
    British Virgin Islands
    Djibouti
    Guyana
    Mikronesiens federerade stater
    Färöarna
    Förenade Arabemiraten
    Caymanöarna
    Egypten
    Paraguay
    Nauru
    Finland
    Georgia
    Costa Rica
    Ekvatorialguinea
    Peru
    Niue
    Frankrike
    Hongkong
    Curaçao
    Elfenbenskusten
    Surinam
    Nordmarianerna
    Gibraltar
    Indien
    Dominica
    Eritrea
    Uruguay
    Norfolk Island
    Grekland
    Indonesien
    Dominikanska republiken
    Etiopien
    Venezuela
    Nya Kaledonien
    Guernsey
    Irak
    El Salvador
    Gabon
    Nya Zeeland
    Irland
    Iran
    Grenada
    Gambia
    Östtimor
    Island
    Israel
    Grönland
    Ghana
    Palau
    Isle of Man
    Japan
    Guadeloupe
    Guinea
    Papua Nya Guinea
    Italien
    Jordanien
    Guatemala
    Guinea-Bissau
    Pitcairn Islands
    Jersey
    Julöarna
    Haiti
    Jamhuri ya Uganda
    Samoa
    Kroatien
    Kambodja
    Honduras
    Kamerun
    Solomon Islands
    Lettland
    Kazakstan
    Jamaica
    Kap Verde
    Tokelauöarna
    Liechtenstein
    Kina
    Kanada
    Kenya
    Tonga
    Litauen
    Kokosöarna
    Karibiska Nederländerna
    Komorerna
    Tuvalu
    Luxemburg
    Kuwait
    Kuba
    Kongo
    United States Minor Outlying Islands
    Malta
    Kyrgyzstan
    Martinique
    Lesotho
    Vanuatu
    Moldavien
    Laos
    Mexiko
    Liberia
    Wallis- och Futunaöarna
    Monaco
    Libanon
    Montserrat
    Libyen
    Montenegro
    Macao
    Nicaragua
    Madagaskar
    Nederländerna
    Malaysia
    Panama
    Malawi
    Nordmakedonien
    Maldiverna
    Puerto Rico
    Mali
    Norge
    Mongoliet
    Saint Christopher och Nevis
    Marocko
    Österrike
    Myanmar (Burma)
    Saint Lucia
    Mauretanien
    Polen
    Nepal
    Saint Vincent och Grenadinerna
    Mauritius
    Portugal
    Oman
    Saint-Barthélemy
    Mayotte
    Rumänien
    Pakistan
    Saint-Martin
    Moçambique
    Ryssland
    Palestina
    Saint-Pierre-et-Miquelon
    Namibia
    San Marino
    Qatar
    Sint Maarten
    Niger
    Schweiz
    Saudiarabien
    Trinidad och Tobago
    Nigeria
    Serbien
    Singapore
    Turks och Caicos Islands
    Réunion
    Slovakien
    Sri Lanka
    USA
    Rwanda
    Slovenien
    Sydkorea
    Saint Helena
    Spanien
    Tadzjikistan
    São Tomé och Príncipe
    Storbritannien
    Taiwan
    Senegal
    Svalbard
    Thailand
    Seychellerna
    Sverige
    Turkiet
    Sierra Leone
    Tjeckien
    Turkmenistan
    Södra Sudan
    Tyskland
    Uzbekistan
    Somalia
    Ukraina
    Vietnam
    Sudan
    Ungern
    Yemen
    Swaziland
    Vatikanstaten
    Sydafrika
    Vitryssland
    Tanzania
    Tchad
    Togo
    Tunisien
    Västsahara
    Zambia
    Zimbabwe