Fire Resistant Cavity/Smoke Barrier
Fire Resistant Cavity/Smoke Barrier
    Promat

    Fire Resistant Cavity/Smoke Barrier

    The purpose of a cavity and smoke barriers is to prevent the spread of smoke and flame from penetrating and/or moving within a concealed space in a fire compartment. Documents supporting the regulations provide guidance on where such barriers should be located within hidden voids in a building and they usually give examples of deemed-to-satisfy barriers for voids in or above stud walls or partitions.

    If a barrier in a concealed space coincides with a compartment wall or floor it will normally be required to provide the same fire performance as the wall or floor. If the barrier is located between such compartment walls or floors however, the barrier is defined as a “cavity barrier” and will normally only be required to provide 30 minute integrity and 15 minute insulation (depending on local building regulations).

    A parapet is a low standing wall above a roof, on top of either an external wall or a fire separating wall. A parapet wall is supposed to prevent fire venting through the roof on one property and crossing over the separating wall down into any adjacent property.

    A spandrel panel is used generally as part of curtain walling systems. The spandrel panel generally protects vertically up from the top of a floor slab, or down from the underside of a floor slab. Spandrel panels are supposed to deflect fire and prevent spread of flames via the ends of floor slabs. A spandrel wall is designed to form a separator at any part of a window or an opening in an external wall above another opening in the storey below. The vertical construction projects no further than 450mm outside the lower opening.

    Parapet and spandrel walls should normally be approved in accordance with the criteria of BS 476: Part 22: 1987, which is required to satisfy a minimum fire resistance of 60/60/60 (for exceptions please check with local building regulations guidance documents or, if relevant, insurance codes).

    Specifikime teknike
    • Referencë unikecavity_barrier
    • Familja e produkteveFire Products
    • Grupi i produkteveCavity and Smoke Barriers
    • LlojiAssembly (objekte të shumëfishta)
    • Data e botimit2021-06-09
    • Numri i botimit1
    • Gjatësia (mm)2440
    • Gjerësia (mm)1220
    Të ngjashme
    • Materiali kryesorCalcium silicate
    • Projektuar nëHong Kong
    • Prodhuar nëHong Kong
    Klasifikimi
    • Kategoria BIMobjectAparateve kundër zjarrit - Mbrojtje
    • IFC classificationObjekt
    • Kodi ETIMEG000056
    • Emri ETIMFire protection systems
    • Emrin UNSPSCFire protection
    • UNSPSC code4619

    Rajoni i disponueshëm

    Asia Oceania
    Armeni
    Australi
    Azerbaixhan
    Fiji
    Bangladesh
    Guam
    Brunei
    Ishujt Cook
    Butan
    Ishujt Marshall
    Filipinet
    Ishujt Minor Periferik të Shteteve të Bashkuara
    Gjeorgji
    Ishujt Pitcairn
    Hong Kong
    Ishujt Solomon
    Indi
    Ishujt Veriore të Marianës
    Indonezi
    Kaledonia e Re
    Ishujt Cocos (Keeling)
    Kiribati
    Japoni
    Nauru
    Kamboxhi
    Niue
    Kazahstan
    Norfolk Island
    Kinë
    Palau
    Kirgistan
    Papua Guinea e Re
    Korea e jugut
    Polinezia franceze
    Korea e Veriut
    Samoa
    Krishtlindje Island
    Samoa amerikane
    Laos
    Shtetet Federale të Mikronezisë
    Macau
    Timor-Leste
    Malazi
    Tokelau
    Maldives
    Tonga
    Mongoli
    Tuvalu
    Myanmar (Burma)
    Vanuatu
    Neoal
    Wallis dhe Futuna
    Pakistan
    Zelanda e Re
    Singapore
    Sri Lanka
    Taiwan
    Tajlandë
    Taxhikistan
    Territori Britanik i Oqeanit Indian
    Turkmenistan
    Uzbekistan
    Vietnam