Airflow Measuring Station - Thermal Dispersion - Aluminum Airfoil Parallel Blade - AM-51-TD
Pottorff

Airflow Measuring Station - Thermal Dispersion - Aluminum Airfoil Parallel Blade - AM-51-TD

Airflow Measuring Station
Aluminum Airfoil - Thermal Dispersion

AM-51-TD airflow measuring stations employ a low leakage control damper with highly accurate airflow measuring equipment in a single compact assembly. The Pottorff CD-51 control damper is factory mounted with a modulating 24V actuator and thermal dispersion airflow measurement system to provide airflow measuring along with the ability to control airflow all in one easy to install assembly. Fully encapsulated precision thermistors are paired with heating circuits and dedicated ELECTRA-flo G5 transmitters to provide a high degree of environmental protection along with state-of-the electronic airflow measurement.

Specifikim
  • Standard Construction

    Damper Frame: 5" x 1" (127 x 25) galvanized steel hat channel with interlocking corner gusset. Equivalent to 13 gauge (2.4) channel frame. Low profile head and sill are used on sizes less than 13" (330) high.

    Damper Blades: 6" (152) heavy gauge, dual wall extruded aluminum - airfoil. Parallel.

    Sleeve: 16" x 20 gauge (406 x 1.0) galvanized steel.

    Damper Axles: 1/2" (13) diameter plated steel hex.

    Damper Linkage: Concealed in frame.

    Damper Bearings: Synthetic.

    Seals: PVC blade edge seals. Flexible metal jamb seals.

    Damper Actuator: Modulating 24V, spring close, external mount.

    Transmitter: ELECTRA-flo G5 with NEMA 1 enclosure.

    Minimum Size: 8" x 6" (203 x 152)

    Maximum Size:
    Single Section: 48" x 72" (1219 x 1829)
    Multiple Section: 120" x 120" (3048 x 3048)

    Ratings

    System Velocity Range: 0-4000 fpm (0-20.32 m/s)

    Maximum System Pressure: 2 in. wg. (0.50 kPa)

    Leakage:
    3.0 cfm/ft2 @ 1.0 in. wg. (0.02 m3/s/m2 @ 0.25 kPa)
    5.0 cfm/ft2 @ 4.0 in. wg. (0.03 m3/s/m2 @ 1.0 kPa)
    7.0 cfm/ft2 @ 10.0 in. wg. (0.04 m3/s/m2 @ 2.5 kPa)

Specifikime teknike
  • Referencë unikeAirflow-Measuring-Station-Thermal-Dispersion-Aluminum-Airfoil-Parallel-Blade-AM-51-TD
  • Familja e produkteveHVAC
  • Grupi i produkteveAir Control Dampers
  • LlojiObjekt (një objekt të vetëm)
  • Data e botimit2024-07-16
  • Numri i botimit1
Klasifikimi
  • Kategoria BIMobjectNgrohes, ventilimit dhe ajrit të kondicionuar - Ventilimi mekanik
  • Uniclass 2015 CodeSs_75_70_96_30
  • Uniclass 2015 PërshkrimFlow measurement and control systems
  • CSI MasterFormat 2014 Code40 71 00
  • CSI MasterFormat 2014 TitleFlow Measurement
  • OmniClass Number23-27 11 15
  • OmniClass TitleFlow Measuring Instrument And Controls

Rajoni i disponueshëm

North America
Anguilla
Antigua dhe Barbuda
Aruba
Bahamas
Barbados
Belize
Bermuda
Dominica
El Salvador
Grenada
Grenlandë
Guadeloupe
Guatemala
Haiti
Honduras
Ishujt e Virgjër Britanikë
Ishujt e Virgjër të SHBA
Ishujt Kajman
Kanadë
Karaibe Holandë
Kolektiviteti i Shën Martinit
Kosta Rika
Kubë
Kuraçao
Martinique
Meksikë
Montserrat
Nikaragua
Panama
Porto Riko
Republika Domenikane
Saint-Barthélemy
Shën Kitts dhe Nevis
Shën Lucia
Shën Pierre dhe Miquelon
Shën Vincent dhe Grenadinet
Shtetet e Bashkuara
Sint Maarten
Trinidad dhe Tobago
Turks dhe Caicos Islands
Xhamaika

Produkte të ngjashme