Опубликуйте свои продукты
Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y
Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y
    Febco

    Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y

    Series LF825Y Lead Free* Y Pattern Reduced Pressure Zone assemblies feature a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.

    This series prevents the reverse flow of contaminated water caused by backsiphonage or backpressure from entering the potable water supply. Ideal for protection at health hazard cross-connections in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. Applications also extend to irrigation systems, boiler feeds, water lines, and other installations requiring maximum protection. Maximum working pressure: 175 psi (12.1 bar).

    Cпецификация
    • Features

      • Ultimate mechanical protection of potable water against cross-connection contamination of high hazard (toxic) fluids in water services
      • Modular relief valve for ease of maintenance
      • Used in industrial plants, hospitals, morgues, mortuaries, chemical plants, irrigation systems, boiler feed, water lines, and other installations
      • Meets all specifications of AWWA, ASSE, CSA and approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

      Outlet Connection Size

      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN

      Inlet Connection Size

      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN
    Техническая спецификация
    • Уникальная ссылкаLF825Y-Reduced-Pressure-Zone-Assembly
    • Тип продукцииBackflow Prevention
    • Группа продукцииReduced Pressure Zone Assemblies
    • ТипОбъект (один объект)
    • Дата публикации2019-05-16
    • Номер версии1
    Связанные
    • Основной материалBronze
    • Разработано вСоединенные Штаты Америки
    • Страна-производительСоединенные Штаты Америки
    Классификация
    • Категория BIMobjectСантехника - Клапаны
    • Классификация IFCКлапан
    • Название по ССКПУ ООНValves
    • Код ССКПУ ООН401416
    • Код Uniclass 2015Pr_65_54_95_05
    • Описание Uniclass 2015Backflow prevention devices
    • Код CSI MasterFormat 201440 05 67.13
    • Заголовок CSI MasterFormat 2014Reduced-Pressure Zone Backflow Preventers for Process Service
    • Номер OmniClass23-27 31 11
    • Наименование OmniClassBackflow Preventors
    • Код CSI UniFormat IID20
    • Заголовок CSI UniFormat IIPLUMBING

    Доступно в регионах: