Опубликуйте свои продукты
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
O2D Fertile Foundation for light vehicle parking lot
    O2D Environnement

    O2D Fertile Foundation for light vehicle parking lot

    O2D fertile foundation material for light vehicle parking is recommended in the context of the development of permeable green parking spaces.

    This foundation material, which is recommended by O2D ENVIRONNEMENT, is comprised of mixtures of crushed roadbed and organic matter. The technical characteristics of this fertile foundation material have been defined in conjunction with the TTE® permeable floor covering: TTE® grids for grassing in situ (TTE MULTIDRAIN) or pre-grassed TTE® grids (O2D GREEN).

    Recommended composition of fertile foundation material:

    • 15 cm thickness: TP GREEN soil and stone foundation material
            o    75% crushed material of particle size 20/40 mm
            o    25% organic substrate (topsoil/washed sand/compost) of particle size 0/10 mm
    • 3 cm thickness: LP GREEN fertile bedding course
            o    60% crushed material of particle size 4/6 mm
            o    20% topsoil/loam mixture of particle size 0/10 mm
            o    20% sand of particle size 0/4 mm

    Prepared base / sub-base (-23 cm in relation to level 0):

    • The requisite permeability below this foundation system is such that K > 10-6 m/s
    • The load-bearing level required is such that EV2 > 40 MPa (EV2/EV1 < 2)
    • We recommend the installation of a permeable anti-contaminant geotextile membrane

    This fertile foundation material composition ensures both load-bearing and drainage capabilities, and provides the requisite nutrients for the effective rooting of grass.

    It is recommended that the thickness of the sub-base (for example, 20/40 mm crushed drainage gravel) should be adjusted and/or any other facility should be incorporated, if the natural ground surface does not possess the requisite infiltration properties, or for the satisfaction of project design requirements.

    The load-bearing level should be appropriate to the intended application.

    Applications:
    - Permeable green parking spaces
    - Permeable parking spaces with combined paving/grass infill
    - Pedestrian or cycle paths

    Cпецификация
    • Recommended deployment for the creation of a fertile foundation for green light vehicle parking spaces:

      - Preparation of base structure

               o  Mechanical or manual execution of excavation and backfill operations, up to the sides of the base structure: - 23 cm in relation to level 0
               o  Surface adjustment and levelling to an altimetric accuracy of +/- 2 cm/m
               o  Confirmation of a permeability coefficient K > 10-6 m/s
               o  Confirmation of the load-bearing capability of ground such that EV2 > 40 MPa, where EV2/EV1 < 2
               o  Clean-up of roadways employed

      - Installation of edging to the concrete foundation, the shoulder of which, at its highest point, is 8 cm below the levelled surface.

      - Installation of a permeable anti-contaminant geotextile membrane

      - Execution of a fertile draining foundation

               o  Adjustment, levelling and vibratory compaction of successive layers of an O2D® TP GREEN ready-to-use soil/stone mixture or equivalent:
                            - 75% crushed material of particle size 20/40 mm
                            - 25% organic substrate (topsoil/washed sand/compost) of particle size 0/10 mm
                    Finished thickness after rolling: 15 cm (or - 8 cm from the levelled edging surface).

               o  Levelling and compaction of O2D® LP GREEN ready-to-use bedding course or equivalent:
                            - 60% crushed material of particle size 4/6 mm
                            - 20% topsoil/loam mixture of particle size 0/10 mm
                            - 20% sand of particle size 0/4 mm
                    Finished thickness: 3 cm (or - 5 cm from the levelled edging surface).

      - Installation of O2D FYNET laying mesh

      - Installation of TTE® O2D GREEN pre-grassed grids, or installation of TTE® grids for grassing in situ.

    Техническая спецификация
    • Уникальная ссылкаfertile-foundation-parking-lot
    • Тип продукцииComplete Systems
    • Группа продукцииGrassed parking lot for light vehicules
    • ТипОбъект (один объект)
    • Дата публикации2019-09-11
    • Номер версии1
    • Высота (мм)180
    Связанные
    • Основной материалЦельный природный камень
    • Вспомогательный материалОрганический материал
    • Разработано вФранция
    • Страна-производительФранция
    Классификация
    • Категория BIMobjectСтроительные материалы - Мощение плиткой и камнями
    • Классификация IFCFloor
    • Название по ССКПУ ООНStone or tile flooring
    • Код ССКПУ ООН30161706
    • Код Uniclass 2015Ss_30_14
    • Описание Uniclass 2015Paving systems
    • Код CSI MasterFormat 201432 01 19
    • Заголовок CSI MasterFormat 2014Rigid Paving Surface Treatment
    • Номер OmniClass23-11 21 17
    • Наименование OmniClassPaving Blocks
    • Код CSI UniFormat IIB1010
    • Заголовок CSI UniFormat IIFloor Construction

    Доступно в регионах:

    Европа Южная Америка Северная Америка Океания Африка
    Бельгия
    Французская Гвиана
    Гваделупа
    Новая Каледония
    Реюньон
    Люксембург
    Мартиника
    о-ва Уоллис и Футуна
    Франция
    Сен-Пьер и Микелон
    Швейцария