Опубликуйте свои продукты
Atena easy expandab.addressable fire al.cont.pan.
Comelit

Atena easy expandab.addressable fire al.cont.pan.

4.3 out of 5 stars4.3(6 reviews)
The ATENA EASY addressable panel is supplied as standard with a loop and can be expanded with a second additional loop by means of expansion card 41ECL022. Up to 250 addressed devices (detectors, buttons, I/O modules, sirens etc.), divided into a maximum of 16 zones, can be connected to each loop. The control panel comes in a strong metal container and displays all indications and commands on the front in compliance with the requirements set out by standard EN54-2, by means of LED light signals and the alphanumeric LCD display with 4 lines of 40 characters. Fire alarm, Fault, CPU Fault, Delayed Alarm, Exclusions, Test, Faulty/Excluded Siren, Confirm Fire Alarm, Faulty/Excluded Alarm Output, Extinguishing Started, Extinction Fault, Network Present, Alarm Silenced general indications. Direct commands for Silence buzzer, Silence siren, Reset, Evacuation, Signalling test. 4 menu navigation keys, ENTER key (Confirm), CANCEL key, keys 1,2,3,4 for setting the access code. Approved to EN 54-2 and EN 54-4.
Cпецификация
  • SOFTWARE/FIRMWARE SPECIFICATIONS
    Event log number: 10.000
    Operating mode With / Without Supervision (Day/Night): Yes
    Programming via PC: With AtenaProg software
    Local programming: Via menu on display and keypad
    FUNCTIONS
    Sensor addressing with electronic programmer 41SPG000.: Yes
    Siren activation delay: 1 - 10 minutes
    Detection with confirmation (dual action): Yes
    HARDWARE SPECIFICATIONS
    Inputs dedicated to interfacing with extinguishing systems: 3
    Number of detection zones available: 48
    Max. number of control panels on redundant RS485 network: 32
    Max. number of devices per loop: 250
    Connection on Ethernet network: Yes
    GENERAL DATA
    Dimensions (W x H x D - mm): 306x412x81mm
    Operating temperature (°C): -10 ÷ 50
    RH max operating humidity (%): (93 ± 3)% @ 40°C
    Certification standard: EN54-2, EN54-4
    Display: Alphanumeric LCD with 4 rows of 40 characters
    Product weight without battery (g): 4200.27
    TECHNICAL CHARACTERISTICS
    Activation delay management: Yes
    ELECTRICAL SPECIFICATIONS
    Main power supply:
    Backup power supply (batteries not supplied): 1x 12 Vdc, 18 Ah, 4.5A fuse
    Power supply for external devices (VDC): 1 x 24
    Mains power absorption (mA): 65
    AC supply voltage: 230VAC (+/-10%), 50Hz
    Outputs for extinguishing system control: 1 (24VDC/0.3A)

Техническая спецификация
  • Уникальная ссылка41CPE012
  • Тип продукцииFIRE
  • Группа продукцииFire
  • ТипОбъект (один объект)
  • Дата публикации2018-11-28
  • Номер версии1
  • Высота (мм)412
  • Ширина (мм)306
  • Глубина (мм)81
Связанные
  • Основной материалМеталл
  • Разработано вИталия
  • Страна-производительИталия
  • Масса нетто (кг)4.2
Классификация
  • Категория BIMobjectПротивопожарное оборудование - Противопожарная защита
  • Код ETIMEC002685
  • Название ETIMCentral fire alarm system
  • Номер OmniClass23-29 31 23
  • Наименование OmniClassFire Alarm Central Stations

Доступно в регионах:

Европа
Австрия
Аландские острова
Албания
Андорра
Беларусь
Бельгия
Болгария
Босния и Герцеговина
Великобритания
Венгрия
Германия
Гернси
Гибралтар
Греция
Дания
Джерси
Ирландия
Исландия
Испания
Италия
Кипр
Латвия
Литва
Лихтенштейн
Люксембург
Мальта
Молдова
Монако
Нидерланды
Норвегия
о-в Мэн
Папский Престол (Государство-город Ватикан)
Польша
Португалия
Россия
Румыния
Сан-Марино
Северная Македония
Сербия
Словакия
Словения
Украина
Фарерские о-ва
Финляндия
Франция
Хорватия
Черногория
Чехия
Швейцария
Швеция
Шпицберген
Эстония