nVent RackChiller Rear Door Cooler, Active
Chemelex
Arquivado

nVent RackChiller Rear Door Cooler, Active

RackChiller Rear Door Cooler (RDC) Heat Exchanger is designed for managing high heat load cooling requirements within high-density server, computing and storage racks. The RDC installs on equipment racks as a separate rear door with an extra frame, enabling it to be retrofitted to existing racks. Heat dissipated by the rack equipment will be removed by the air-to-liquid heat exchanger and transfered into the facility water circuit, adding no heat to the IT room. Door-mounted fans support the IT equipment air flow to overcome the coil impedance. The integrated controller modulates the water flow to keep a constant supply air temperature, as well as the fan speed to maintaining a (configurable) pressure differential between rack and IT room. The entire system is integrated within an aesthetically framed perforated door with protective covers to isolate the liquid source and cooling loop from the rack-mounted equipment.

Especificação
  • Features & Benefits

    • Active solution with fans supporting air flow and neutralizing the pressure drop at the heat exchanger
    • Frame solution separates coil and condensate management from the rack-mounted equipment
    • Rear space inside the cabinet is left available for power distribution and cable management
    • Easily adapts to nVent cabinets; contact nVent to request information for integrating with third party cabinets
    • Temperature sensors on air supply and return side
    • Integrated control system with Modbus TCP and SNMP v2c interface
    • Optional water flow, pressure and temperature sensors included with the water control package allow for water monitoring and regulation according to actual heat load
    • Optional local display

    For trouble-free operation it is recommended to use the water connection set and the optional accessories.The cooling capacity is determined under the following conditions: delta p water: < 100 kPa; water flow temperature: 12 °C / 53.6 °F; outlet temperature 24 °C / 75.2 °F; water flow: 4.8 m³/h / 21.1 gal/min ; Airflow: Depending on cooling module, see Diagram Performance Map.

Especificações técnicas
  • Ref.ª únicaRackChiller-Rear-Door-Cooler-Active
  • Familia de productonVent Data Center Solutions
  • Grupo de produtosRear Door Heat Exchangers
  • TipoObject (objeto único)
  • Data de publicação2023-03-16
  • Número de edição1
Relacionado
  • Material principalAço
  • Concebido emUnited States
  • Fabricado emUnited States
Classificação
  • Categoria BIMobjectAVAC - Permutador de calor
  • ETIM CodeEG015220
  • ETIM NameHeat exchangers
  • Uniclass 2015 CódigoPr_60_60_38
  • Uniclass 2015 DescriçãoCalorifiers and plate heat exchangers
  • Código CSI MasterFormat 201423 57 00
  • Título CSI MasterFormat 2014Heat Exchangers for HVAC
  • Número OmniClass23-27 23 00
  • Título OmniclassHeat Exchangers