Publique seus produtos
Bioretention Planters, GFRC
Bioretention Planters, GFRC
Bioretention Planters, GFRC
    Tournesol

    Bioretention Planters, GFRC

    Traduzido pelo Google,

    GFRC - CONCRETO LEVE

    Nossos plantadores de bioretenção são pré-construídos e instalados no local para coletar águas pluviais de drenos/calhas. As plantas e os meios filtram a água, removendo sólidos orgânicos e inorgânicos, e liberam lentamente a água nos bueiros, reduzindo as taxas de pico de descarga.
    Oferecemos uma variedade de tamanhos padrão em alumínio e GFRC – concreto reforçado com fibra de vidro, mas a maioria dos projetos de bioretenção são personalizados.

    Especificação
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Interior Planters

      Tournesol Siteworks Fiberglass Planters and Planter Liners

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of fiberglass planters and planter liners

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete

      B. Section 061000 Rough Carpentry

      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.

      B. Samples: As required for color selection or material thickness only.

      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for

      installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap and inspect planters and planter liners after delivery for signs of damage during

      transit.

      B. Protect planters and planter liners from damage during storage and handling.

      C. Store planters and planter liners indoors if possible. Do not stand or walk on planters or

      planter liners.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planter liner units. Unless

      otherwise specified, planters and liners should have continuous basal support.

      B. Protect units from damage by adjacent work.

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Fiberglass Planters and planter liners, manufactured by Tournesol Siteworks LLC. 30955

      San Antonio St., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 FIBERGLASS PLANTERS AND PLANTER LINERS

      A. Materials - All parts shall be constructed of glass fiber-reinforced polyester resin, using

      either the hand-layup or spray-layup methods.

      1. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform

      chopped strand mat, minimum 3 oz. density. Smaller round containers will use one layer

      of mat (or spray equivalent), smaller squares and larger round containers must use two

      layers (or spray equivalent), larger square and rectangular containers must use min. 3

      layers (or spray equivalent).

      2. Polyester resin shall be compounded by a reputable manufacturer. All planters and

      planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      3. Gel coating (where necessary) shall be of specified color. Metallic finishes will use

      atomized metal thoroughly blended with polyester resin, and applied over clean surfaces.

      4. Painted finishes will be made of polyurethane low VOC (less than 2.8 VOC) enamel

      with excellent corrosion and chemical resistance by PPG (AUE 280) or equivalent.

      B. Construction

      Architectural parts shall be fabricated by hand-layup, spray laminate, or resin transfer

      method using suitable molds to attain the desired surface finish. The finished reinforced

      plastic material shall be not less than 5/32" thick and thicker in those areas requiring

      additional structural strength.

      Where ribs or stiffeners are to be fastened to liner sections by spray laminating over

      premolded forms, the stiffeners or ribs shall be located and spray laminated into position so

      that the finished joint shall conform to performance specifications below.

      For vertical surface reinforcement, an inorganic honeycomb strengthening layer using

      double-veiled, bonded material shall be located and hand- or spray-laminted into position

      prior to the wall material setting. The entire honeycomb panel must be subject to pressure

      during curing to ensure proper bonding to wall. Honeycomb thickness will be minimum

      ¼”, or thicker as required for larger spans. Marine-grade plywood may be substituted for

      bottom panels to be penetrated with drainage or irrigation holes.

      Interior of planter or planter liner to be waterproofed with additional layer of black gel

      coating, additional waterproofing available as specified.

      C. Performance characteristics and capacities, finished product to yield the following

      minimum performances:

      Hardness, Barcol 50

      Tensile Strength, Ultimate 12500 psi

      Elongation at break 1.3%

      Modulus of Elasticity 1020 ksi

      Flexural Modulus 754 ksi

      Flexural Yield Strength 27600 psi

      Compressive Yield Strength 21800 psi

      Glass content, average 35%

      Vertical wall panels will not deform more than L/200 when loaded with 80 lbs/cu ft. soil

      mass. Similar performance with heavier media is available per specification.

      D. Finish: specified finish; factory finished.

      E. Sizes: Modular units fabricated to size by manufacturer as required to fill specified

      areas. Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      F. Fire retardant requirement can be met with the addition of retardant chemicals to the

      resin. Additional information is available for this specification.

      2.3 PLANTER ACCESSORIES

      A. Field installed drainage/irrigation connection fitting. Thread-by-thread thermoplastic

      drainage adapter, ½”, ¾” and 1"NPT female thread available. Contractor to locate drainage

      hole, drill as necessary, and install fitting.

      B. Lifting hooks or stabilizer anchors, quantity, size, and capacity as specified.

      3.0 EXECUTION

      3.1 PREPARATION

      A. Prior to planter or planter liner fabrication, the contractor shall verify as-built dimensions

      of planter area or receptacles to ensure proper size, fit and quantity required.1

      B. Unless planters have drainage fittings as in 2.3.A, drainage holes to be located and made

      by contractor in the field to fit to drainage system.

      3.2 INSTALLATION

      A. Install planter liners to allow for easy removal if necessary.

      B. Provide continuous basal support.

      C. Install liners level to permit adequate drainage and irrigation.

      1 Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can

      lead to delays and additional cost if neglected.

    Especificação técnica
    • Ref. únicabioretention-planters-gfrc
    • Família de produtoBioretention Planters
    • Grupo de produtosBioretention GFRC
    • TipoObjeto (objeto único)
    • Data de publicação2024-06-04
    • Número da edição1
    Afins
    • Material principalConcreto
    • Desenhado emUnited States
    • Fabricado emUnited States
    Classificação
    • Categoria BIMobjectPaisagismo - Outros

    Disponibilidade regional

    Europa América do Norte Ásia América do Sul
    Åland Islands
    Anguilla
    Armenia
    Argentina
    Albania
    Antigua and Barbuda
    Azerbaijan
    Bolivia
    Andorra
    Aruba
    Bangladesh
    Brasil
    Austria
    Barbados
    Bhutan
    Chile
    Belarus
    Belize
    British Indian Ocean Territory
    Colombia
    Belgium
    Bermuda
    Brunei
    Ecuador
    Bosnia and Herzegovina
    British Virgin Islands
    Cambodia
    Falkland Islands (Islas Malvinas)
    Bulgaria
    Canada
    China
    French Guiana
    Croatia
    Caribbean Netherlands
    Christmas Island
    Guyana
    Cyprus
    Cayman Islands
    Cocos (Keeling) Islands
    Paraguay
    Czech Republic
    Collectivity of Saint Martin
    Georgia
    Peru
    Denmark
    Costa Rica
    Hong Kong
    Suriname
    Estonia
    Cuba
    India
    Uruguay
    Faroe Islands
    Curaçao
    Indonesia
    Venezuela
    Finland
    Dominica
    Japan
    France
    Dominican Republic
    Kazakhstan
    Germany
    El Salvador
    Kyrgyzstan
    Gibraltar
    Greenland
    Laos
    Greece
    Grenada
    Macau
    Guernsey
    Guadeloupe
    Malaysia
    Hungary
    Guatemala
    Maldives
    Iceland
    Haiti
    Mongolia
    Ireland
    Honduras
    Myanmar (Burma)
    Isle of Man
    Jamaica
    Nepal
    Italy
    Martinique
    North Korea
    Jersey
    Mexico
    Pakistan
    Latvia
    Montserrat
    Philippines
    Liechtenstein
    Nicaragua
    Singapore
    Lithuania
    Panama
    South Korea
    Luxembourg
    Puerto Rico
    Sri Lanka
    Macedônia do Norte
    Saint Kitts and Nevis
    Taiwan
    Malta
    Saint Lucia
    Tajikistan
    Moldova
    Saint Pierre and Miquelon
    Thailand
    Monaco
    Saint Vincent and the Grenadines
    Turkmenistan
    Montenegro
    Saint-Barthélemy
    Uzbekistan
    Netherlands
    Sint Maarten
    Vietnam
    Norway
    The Bahamas
    Poland
    Trinidad and Tobago
    Portugal
    Turks and Caicos Islands
    Romania
    U.S. Virgin Islands
    Russia
    United States
    San Marino
    Serbia
    Slovakia
    Slovenia
    Spain
    Svalbard and Jan Mayen
    Sweden
    Switzerland
    Ukraine
    United Kingdom
    Vatican City