Opublikuj swoje produkty
Bioretention Planters, GFRC
Bioretention Planters, GFRC
Bioretention Planters, GFRC
    Tournesol

    Bioretention Planters, GFRC

    GFRC - LIGHTWEIGHT CONCRETE

    Our bioretention planters are pre-built and installed on-site to collect stormwater from drain leads/downspouts. Plants and media filter water, removing organic and inorganic solids, and slowly release the water into the storm drains, reducing peak discharge rates.
    We offer a range of standard sizes in both aluminum and GFRC - Glass-fiber reinforced concrete, but most bioretention projects are custom.

    Opis
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Interior Planters

      Tournesol Siteworks Fiberglass Planters and Planter Liners

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of fiberglass planters and planter liners

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete

      B. Section 061000 Rough Carpentry

      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.

      B. Samples: As required for color selection or material thickness only.

      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for

      installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap and inspect planters and planter liners after delivery for signs of damage during

      transit.

      B. Protect planters and planter liners from damage during storage and handling.

      C. Store planters and planter liners indoors if possible. Do not stand or walk on planters or

      planter liners.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planter liner units. Unless

      otherwise specified, planters and liners should have continuous basal support.

      B. Protect units from damage by adjacent work.

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Fiberglass Planters and planter liners, manufactured by Tournesol Siteworks LLC. 30955

      San Antonio St., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 FIBERGLASS PLANTERS AND PLANTER LINERS

      A. Materials - All parts shall be constructed of glass fiber-reinforced polyester resin, using

      either the hand-layup or spray-layup methods.

      1. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform

      chopped strand mat, minimum 3 oz. density. Smaller round containers will use one layer

      of mat (or spray equivalent), smaller squares and larger round containers must use two

      layers (or spray equivalent), larger square and rectangular containers must use min. 3

      layers (or spray equivalent).

      2. Polyester resin shall be compounded by a reputable manufacturer. All planters and

      planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      3. Gel coating (where necessary) shall be of specified color. Metallic finishes will use

      atomized metal thoroughly blended with polyester resin, and applied over clean surfaces.

      4. Painted finishes will be made of polyurethane low VOC (less than 2.8 VOC) enamel

      with excellent corrosion and chemical resistance by PPG (AUE 280) or equivalent.

      B. Construction

      Architectural parts shall be fabricated by hand-layup, spray laminate, or resin transfer

      method using suitable molds to attain the desired surface finish. The finished reinforced

      plastic material shall be not less than 5/32" thick and thicker in those areas requiring

      additional structural strength.

      Where ribs or stiffeners are to be fastened to liner sections by spray laminating over

      premolded forms, the stiffeners or ribs shall be located and spray laminated into position so

      that the finished joint shall conform to performance specifications below.

      For vertical surface reinforcement, an inorganic honeycomb strengthening layer using

      double-veiled, bonded material shall be located and hand- or spray-laminted into position

      prior to the wall material setting. The entire honeycomb panel must be subject to pressure

      during curing to ensure proper bonding to wall. Honeycomb thickness will be minimum

      ¼”, or thicker as required for larger spans. Marine-grade plywood may be substituted for

      bottom panels to be penetrated with drainage or irrigation holes.

      Interior of planter or planter liner to be waterproofed with additional layer of black gel

      coating, additional waterproofing available as specified.

      C. Performance characteristics and capacities, finished product to yield the following

      minimum performances:

      Hardness, Barcol 50

      Tensile Strength, Ultimate 12500 psi

      Elongation at break 1.3%

      Modulus of Elasticity 1020 ksi

      Flexural Modulus 754 ksi

      Flexural Yield Strength 27600 psi

      Compressive Yield Strength 21800 psi

      Glass content, average 35%

      Vertical wall panels will not deform more than L/200 when loaded with 80 lbs/cu ft. soil

      mass. Similar performance with heavier media is available per specification.

      D. Finish: specified finish; factory finished.

      E. Sizes: Modular units fabricated to size by manufacturer as required to fill specified

      areas. Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      F. Fire retardant requirement can be met with the addition of retardant chemicals to the

      resin. Additional information is available for this specification.

      2.3 PLANTER ACCESSORIES

      A. Field installed drainage/irrigation connection fitting. Thread-by-thread thermoplastic

      drainage adapter, ½”, ¾” and 1"NPT female thread available. Contractor to locate drainage

      hole, drill as necessary, and install fitting.

      B. Lifting hooks or stabilizer anchors, quantity, size, and capacity as specified.

      3.0 EXECUTION

      3.1 PREPARATION

      A. Prior to planter or planter liner fabrication, the contractor shall verify as-built dimensions

      of planter area or receptacles to ensure proper size, fit and quantity required.1

      B. Unless planters have drainage fittings as in 2.3.A, drainage holes to be located and made

      by contractor in the field to fit to drainage system.

      3.2 INSTALLATION

      A. Install planter liners to allow for easy removal if necessary.

      B. Provide continuous basal support.

      C. Install liners level to permit adequate drainage and irrigation.

      1 Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can

      lead to delays and additional cost if neglected.

    Specyfikacja techniczna
    • Nr referencyjnybioretention-planters-gfrc
    • Rodzina produktuBioretention Planters
    • Grupa produktuBioretention GFRC
    • TypObiekt (jeden obiekt)
    • Data publikacji2024-06-04
    • Numer edycji1
    Dodatkowe informacje
    • Materiał głównyBeton
    • Zaprojektowano wStany Zjednoczone
    • Wyprodukowano wStany Zjednoczone
    Klasyfikacja
    • Kategoria BIMobjectArchitektura krajobrazu - Krajobraz - pozostałe

    Dostępny w krajach:

    Europa Ameryka północna Azja Ameryka Południowa
    Albania
    Anguilla
    Armenia
    Argentyna
    Andora
    Antigua i Barbuda
    Azerbejdżan
    Boliwia
    Austria
    Aruba
    Bangladesz
    Brazylia
    Belgia
    Bahamy
    Bhutan
    Chile
    Białoruś
    Barbados
    Brunei Darussalam
    Ekwador
    Bośnia i Hercegowina
    Belize
    Brytyjskie Terytorium Oceanu Indyjskiego
    Falklandy (Malwiny)
    Bułgaria
    Bermudy
    Chiny
    Gujana
    Chorwacja
    Brytyjskie Wyspy Dziewicze
    Filipiny
    Gujana Francuska
    Cypr
    Curaçao
    Gruzja
    Kolumbia
    Czarnogóra
    Dominika
    Hongkong
    Paragwaj
    Czechy
    Dominikana
    Indie
    Peru
    Dania
    Grenada
    Indonezja
    Surinam
    Estonia
    Grenlandia
    Japonia
    Urugwaj
    Finlandia
    Gwadelupa
    Kambodża
    Wenezuela
    Francja
    Gwatemala
    Kazachstan
    Gibraltar
    Haiti
    Kirgistan
    Grecja
    Holandia Karaibska
    Korea Północna
    Guernsey
    Honduras
    Korea Południowa
    Hiszpania
    Jamajka
    Laos
    Holandia
    Kajmany
    Makau
    Irlandia
    Kanada
    Malediwy
    Islandia
    Kostaryka
    Malezja
    Jersey
    Kuba
    Mongolia
    Liechtenstein
    Martynika
    Myanmar (Birma)
    Litwa
    Meksyk
    Nepal
    Łotwa
    Montserrat
    Pakistan
    Luksemburg
    Nikaragua
    Singapur
    Macedonia Pólnocna
    Panama
    Sri Lanka
    Malta
    Portoryko
    Tadżykistan
    Man
    Saint Kitts i Nevis
    Tajlandia
    Mołdawia
    Saint Lucia
    Tajwan
    Monako
    Saint Martin
    Turkmenistan
    Niemcy
    Saint Vincent i Grenadyny
    Uzbekistan
    Norwegia
    Salwador
    Wietnam
    Polska
    Sint Maarten
    Wyspa Bożego Narodzenia
    Portugalia
    Stany Zjednoczone
    Wyspy Kokosowe
    Rosja
    Trynidad i Tobago
    Rumunia
    Turks i Caicos
    San Marino
    Wspólnota Saint-Barthélemy
    Serbia
    Wspólnota Terytorialna Saint Pierre i Miquelon
    Słowacja
    Wyspy Dziewicze
    Słowenia
    Svalbard
    Szwajcaria
    Szwecja
    Ukraina
    Watykan
    Węgry
    Wielka Brytania
    Włochy
    Wyspy Alandzkie
    Wyspy Owcze