CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

The CHV-TSTAT-FCU is a versatile heating and cooling thermostat for fan coil unit (FCU) HVAC systems. Relative humidity capability can be added through an external remote humidity sensor (sold separately). Although functional as a standalone thermostat, the CHV-TSTAT delivers greatly enhanced functionality as part of a complete home automation system from Crestron®. Available in white, black, or almond, the stylish wall mount design is a complement to any décor.

The large backlit LCD display, navigable using four simple pushbuttons, provides easy access to indoor and outdoor temperature and humidity readings, setpoint adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity setpoints with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.

Automation System Integration
Multiple Crestron thermostats may be networked via Cresnet® to any 3-Series® control system, including the DIN-AP3, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.

Its connection to the control system also allows for full control and scheduling of the CHV-TSTAT-FCU from touch screens and computers throughout the home, and supports extensive flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT-FCU will remain operable to control the HVAC system.

Remote Sensors
Optional remote temperature and humidity sensors can be connected to the CHV-TSTAT-FCU for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT-FCU to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low-temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT-FCU accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity sensor and two temperature sensors.

Features
Summary Of Features

Wall-mount thermostat for fan coil unit HVAC systems
Multiple Crestron® thermostats may be networked via Cresnet®
Supports remote humidity sensors and outdoor temperature sensors
Backlit LCD display
Front panel buttons for setup, configuring, and temperature and humidity adjustments[1]
Available in white, black, or almond finishes

Notes:
1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Opis
  • Measurement Range
     
    Indoor Temperature: 0° to 110°F (-18° to 43°C)
    Outdoor Temperature: -40° to 170°F (-40° to 77°C)[1]
    Humidity: 0% to 100% RH[1]

    Temperature Tolerance
    Over Full Range: ±1°F (±0.5°C)
    At Room Temperatures: ±1°F (+0.1/-0.4°C)

    Setpoint Range
    Auto Setpoint: 38° to 99°F (3° to 37°C)
    Heat only Setpoint: 38° to 89°F (3° to 32°C)
    Cool only Setpoint: 59° to 99°F (15° to 37°C), or 38° to 99°F (3° to 37°C) extended cool mode enabled
    Humidity Setpoint:5% to 70% RH[1]

    Relay Rating
    1 Amp at 40 Volts DC or 24 Volts AC (nominal)

    Power Requirements
    24V: 2 Watts (0.083 Amps) at 24 Volts AC, supplied by heating or cooling system
    Cresnet® Power Usage: ‹1 Watts (‹0.05 Amps at 24 Volts DC), required for Cresnet communication only

    Buttons
    MODE: Accesses user controls - system mode, fan mode, humidifier,[1] Crestron® system, and global update
    VIEW: Accesses humidity reading,[1] outdoor temperature reading,[1] system messages, and remote functions
    UP: Selects user modes and increments selection in setup modes
    DOWN: Selects user modes and decrements selection in setup modes

    Display
    Type: Transflective LCD, backlit
    Size: 2.75 in (6.99 cm)
    Resolution: 128 x 64
    Viewing Angle: ±50° horizontal (at 0° vertical), ±50° vertical (at 0° horizontal)
    Displays current indoor temperature and relative humidity,[1] outdoor temperature and relative humidity,[1] setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages

    Connections
    HVAC:
    (2) 9-position terminal blocks comprising the following:

    Power Connections (Required):
    24 (C): 24V AC common terminal supplies remote 24V AC power to thermostat;
    24 (R): 24V AC reference terminal – Can be connected to R by P4 jumper setting, or tied directly to power source

    HVAC Control Connections (System Dependent):
    HUM, RHU: Humidity Control – Energized together during humidity call;
    R, R: Reference – Used for all system calls (except humidity);
    G-L: Fan Low – Energized to R during call for low-speed fan;
    G-M: Fan – Energized to R during call for medium-speed fan;
    G-H: Fan – Energized to R during call for high-speed fan;
    O: Changeover control – Energized to R during cooling modes;
    B: Energized to R during non-cooling modes;
    W: Heat – Energized to R during call for heating;
    Y: Cool – Energized to R during call for cooling

    Remote Sensing Connections (Optional):
    RSR: Remote Sensor Returns – Common sensor terminal;
    RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
    RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
     
    Network
    (1) 4-position terminal block;
    Cresnet slave port, connects to Cresnet control network

    Enclosure
    Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box

    Dimensions
    Height: 3.75 in (96 mm)
    Width: 5.00 in (127 mm)
    Depth: 1.04 in (27 mm)
    Weight: 5.80 oz (165 g)

    Notes:
    1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Specyfikacja techniczna
  • Nr referencyjnycrestron-CHV-TSTAT-FCU
  • Rodzina produktuLighting & Environment
  • Grupa produktuClimate Control
  • TypObiekt (jeden obiekt)
  • Data publikacji2017-12-10
  • Numer edycji1
  • Wysokość (cale)3.75
  • Szerokość (cale)5
  • Głębokość (cale)1.04
Dodatkowe informacje
  • Materiał głównyPlastikowy
  • Zaprojektowano wMeksyk
  • Wyprodukowano wMeksyk
  • Waga netto (lbs)0.3625
Klasyfikacja
  • Kategoria BIMobjectElementy elektroniczne - Sterowniki
  • Klasyfikacja IFCElement elektryczny
  • CSI MasterFormat 2014 Code40 74 00
  • CSI MasterFormat 2014 TitleTemperature Measurement
  • OmniClass Number23-27 11 11 15 11
  • OmniClass TitleDigital Temperature Controllers

Dostępny w krajach:

Europa Azja Ameryka północna Afryka Ameryka Południowa Oceania
Albania
Afganistan
Anguilla
Algieria
Argentyna
Australia
Andora
Arabia Saudyjska
Antigua i Barbuda
Angola
Boliwia
Dalekie Wyspy Mniejsze Stanów Zjednoczonych
Austria
Armenia
Aruba
Benin
Brazylia
Fidżi
Belgia
Azerbejdżan
Bahamy
Botswana
Chile
Guam
Białoruś
Bahrajn
Barbados
Burkina Faso
Ekwador
Kiribati
Bośnia i Hercegowina
Bangladesz
Belize
Burundi
Falklandy (Malwiny)
Mariany Północne
Bułgaria
Bhutan
Bermudy
Czad
Gujana
Mikronezja
Chorwacja
Brunei Darussalam
Brytyjskie Wyspy Dziewicze
Demokratyczna Republika Konga
Gujana Francuska
Nauru
Cypr
Brytyjskie Terytorium Oceanu Indyjskiego
Curaçao
Dżibuti
Kolumbia
Niue
Czarnogóra
Chiny
Dominika
Egipt
Paragwaj
Norfolk
Czechy
Filipiny
Dominikana
Erytrea
Peru
Nowa Kaledonia
Dania
Gruzja
Grenada
Etiopia
Surinam
Nowa Zelandia
Estonia
Hongkong
Grenlandia
Gabon
Urugwaj
Palau
Finlandia
Indie
Gwadelupa
Gambia
Wenezuela
Papua-Nowa Gwinea
Francja
Indonezja
Gwatemala
Ghana
Pitcairn
Gibraltar
Irak
Haiti
Gwinea
Polinezja Francuska
Grecja
Iran
Holandia Karaibska
Gwinea Bissau
Samoa
Guernsey
Izrael
Honduras
Gwinea Równikowa
Samoa Amerykańskie
Hiszpania
Japonia
Jamajka
Kamerun
Timor Wschodni
Holandia
Jemen
Kajmany
Kenia
Tokelau
Irlandia
Jordania
Kanada
Komory
Tonga
Islandia
Kambodża
Kostaryka
Kongo
Tuvalu
Jersey
Katar
Kuba
Lesotho
Vanuatu
Liechtenstein
Kazachstan
Martynika
Liberia
Wallis i Futuna
Litwa
Kirgistan
Meksyk
Libia
Wyspy Cooka
Łotwa
Korea Północna
Montserrat
Madagaskar
Wyspy Marshalla
Luksemburg
Korea Południowa
Nikaragua
Majotta
Wyspy Salomona
Macedonia Pólnocna
Kuwejt
Panama
Malawi
Malta
Laos
Portoryko
Mali
Man
Liban
Saint Kitts i Nevis
Maroko
Mołdawia
Makau
Saint Lucia
Mauretania
Monako
Malediwy
Saint Martin
Mauritius
Niemcy
Malezja
Saint Vincent i Grenadyny
Mozambik
Norwegia
Mongolia
Salwador
Namibia
Polska
Myanmar (Birma)
Sint Maarten
Niger
Portugalia
Nepal
Stany Zjednoczone
Nigeria
Rosja
Oman
Trynidad i Tobago
Republika Południowej Afryki
Rumunia
Pakistan
Turks i Caicos
Republika Środkowoafrykańska
San Marino
Palestyna
Wspólnota Saint-Barthélemy
Reunion
Serbia
Singapur
Wspólnota Terytorialna Saint Pierre i Miquelon
Rwanda
Słowacja
Sri Lanka
Wyspy Dziewicze
Sahara Zachodnia
Słowenia
Syria
Senegal
Svalbard
Tadżykistan
Seszele
Szwajcaria
Tajlandia
Sierra Leone
Szwecja
Tajwan
Somalia
Ukraina
Turcja
Suazi
Watykan
Turkmenistan
Sudan
Węgry
Uzbekistan
Sudan Południowy
Wielka Brytania
Wietnam
Święta Helena
Włochy
Wyspa Bożego Narodzenia
Tanzania
Wyspy Alandzkie
Wyspy Kokosowe
Togo
Wyspy Owcze
Zjednoczone Emiraty Arabskie
Tunezja
Uganda
Wybrzeże Kości Słoniowej
Wyspy Świętego Tomasza i Książęca
Wyspy Zielonego Przylądka
Zambia
Zimbabwe