Hurricane Miami-Dade Louver - 9" Deep - 37-1/2 Degree J-Blade with Vertical Rear Section - Extruded Aluminum - EFJ-937-MD
Pottorff

Hurricane Miami-Dade Louver - 9" Deep - 37-1/2 Degree J-Blade with Vertical Rear Section - Extruded Aluminum - EFJ-937-MD

Dual-Module Louver
9" Deep - 37-1/2 Degree J-Blade with Vertical Rear Section

The EFJ-937-MD dual-module louver is engineered and tested to withstand extreme loads, debris impact, and cyclic fatigue associated with the severe weather effects of hurricanes (Miami-Dade County approval #21-1122.07. The front (exterior) side of the louver features horizontal J-style blades for a pleasing architectural appearance. The back (interior) side has vertical chevron blades which provide superior resistance to wind-driven rain. For installation, the EFJ-937-MD offers multiple options requiring minimal hardware and assembly time. The EFJ-937-MD is AMCA 540 and 550 listed, making it ideally suited for use in hurricane-prone and wind-borne debris regions per the International Building Code.

Spesifikasjon
  • Standard Construction

    Material: Mill finish extruded aluminum.

    Frames: 6" deep x 0.125" thick (152 x 3) channel.

    Blades:
    Front:
    37o x 0.081" (2.1) thick horizontal J-style.
    Rear: 0.060" (1.5) thick vertical chevron

    Screen: 1/2" x 0.063" (12.7 x 1.6) expanded and flattened aluminum.

    Mullion: Visible.

    Minimum Size: 12" x 12" (305 x 305)

    Maximum Size:
    Single Section: 60" x 120" (1524 x 3048)
    Multiple Section: Unlimited width x 120" (3048)


    Ratings

    Free Area: 8.6 ft2 (0.80 m2)

    Performance @ Beginning Point of Water Penetration

    Free Area Velocity: 1250 fpm (6.35 m/s)

    Air Volume Delivered: 10755 cfm (5.09 m3/s)

    Pressure Loss: 0.48 in. wg. (121 Pa)

    Velocity @ 0.15 in. wg. Pressure Loss: 705 fpm (3.58 m/s)

    Design Load: 130 psf

    AMCA 540 and 550 Listed
    AMCA Certified for Water Penetration, Air Performance and Wind-Driven Rain
    Miami-Dade County approved: NOA No. 21-1122.07
    Florida Building Code approval (2020-FBC): No. FL27568
    Texas Department of Insurance Listed

Tekniske spesifikasjoner
  • Unik ref.Hurricane-Miami-Dade-Louver-9-Deep-37-1-2-Degree-J-Blade-with-Vertical-Rear-Section-Extruded-Aluminum-EFJ-937-MD
  • ProduktfamilieHVAC
  • ProduktgruppeLouvers and Penthouses
  • TypeObjekt (enkelt objekt)
  • Utgivelsesdato2024-07-16
  • Utgavenummer1
Klassifisering
  • BIMobject kategoriVVS - Kanaler
  • Uniclass 2015 kodePr_30_59_48
  • Uniclass 2015 beskrivelseLouvres and components
  • CSI MasterFormat 2014 kode08 91 00
  • CSI MasterFormat 2014 tittelLouvers
  • OmniClass-nummer23-33 29 31
  • OmniClass-tittelLouvre Dampers

Tilgjengelighet etter region

Nord Amerika
Anguilla
Antigua og Barbuda
Aruba
Bahamas
Barbados
Belize
Bermuda
Canada
Cayman Islands
Costa Rica
Cuba
Curaçao
Den dominikanske republikk
Dominica
El Salvador
Grenada
Grønland
Guadeloupe
Guatemala
Haiti
Honduras
Jamaica
Jomfruøyene
Jomfruøyene
Karibisk Nederland
Martinique
Mexico
Montserrat
Nicaragua
Panama
Puerto Rico
Saint Kitts og Nevis
Saint Lucia
Saint Pierre og Miquelon
Saint Vincent og Grenadinene
Saint-Barthélemy
Saint-Martin
Sint Maarten
Trinidad og Tobago
Turks- og Caicosøyene
USA