    GFRC - LIGHTWEIGHT CONCRETE

    Our bioretention planters are pre-built and installed on-site to collect stormwater from drain leads/downspouts. Plants and media filter water, removing organic and inorganic solids, and slowly release the water into the storm drains, reducing peak discharge rates.
    We offer a range of standard sizes in both aluminum and GFRC - Glass-fiber reinforced concrete, but most bioretention projects are custom.

    Spesifikasjon
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Interior Planters

      Tournesol Siteworks Fiberglass Planters and Planter Liners

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of fiberglass planters and planter liners

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete

      B. Section 061000 Rough Carpentry

      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.

      B. Samples: As required for color selection or material thickness only.

      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for

      installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap and inspect planters and planter liners after delivery for signs of damage during

      transit.

      B. Protect planters and planter liners from damage during storage and handling.

      C. Store planters and planter liners indoors if possible. Do not stand or walk on planters or

      planter liners.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planter liner units. Unless

      otherwise specified, planters and liners should have continuous basal support.

      B. Protect units from damage by adjacent work.

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Fiberglass Planters and planter liners, manufactured by Tournesol Siteworks LLC. 30955

      San Antonio St., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 FIBERGLASS PLANTERS AND PLANTER LINERS

      A. Materials - All parts shall be constructed of glass fiber-reinforced polyester resin, using

      either the hand-layup or spray-layup methods.

      1. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform

      chopped strand mat, minimum 3 oz. density. Smaller round containers will use one layer

      of mat (or spray equivalent), smaller squares and larger round containers must use two

      layers (or spray equivalent), larger square and rectangular containers must use min. 3

      layers (or spray equivalent).

      2. Polyester resin shall be compounded by a reputable manufacturer. All planters and

      planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      3. Gel coating (where necessary) shall be of specified color. Metallic finishes will use

      atomized metal thoroughly blended with polyester resin, and applied over clean surfaces.

      4. Painted finishes will be made of polyurethane low VOC (less than 2.8 VOC) enamel

      with excellent corrosion and chemical resistance by PPG (AUE 280) or equivalent.

      B. Construction

      Architectural parts shall be fabricated by hand-layup, spray laminate, or resin transfer

      method using suitable molds to attain the desired surface finish. The finished reinforced

      plastic material shall be not less than 5/32" thick and thicker in those areas requiring

      additional structural strength.

      Where ribs or stiffeners are to be fastened to liner sections by spray laminating over

      premolded forms, the stiffeners or ribs shall be located and spray laminated into position so

      that the finished joint shall conform to performance specifications below.

      For vertical surface reinforcement, an inorganic honeycomb strengthening layer using

      double-veiled, bonded material shall be located and hand- or spray-laminted into position

      prior to the wall material setting. The entire honeycomb panel must be subject to pressure

      during curing to ensure proper bonding to wall. Honeycomb thickness will be minimum

      ¼”, or thicker as required for larger spans. Marine-grade plywood may be substituted for

      bottom panels to be penetrated with drainage or irrigation holes.

      Interior of planter or planter liner to be waterproofed with additional layer of black gel

      coating, additional waterproofing available as specified.

      C. Performance characteristics and capacities, finished product to yield the following

      minimum performances:

      Hardness, Barcol 50

      Tensile Strength, Ultimate 12500 psi

      Elongation at break 1.3%

      Modulus of Elasticity 1020 ksi

      Flexural Modulus 754 ksi

      Flexural Yield Strength 27600 psi

      Compressive Yield Strength 21800 psi

      Glass content, average 35%

      Vertical wall panels will not deform more than L/200 when loaded with 80 lbs/cu ft. soil

      mass. Similar performance with heavier media is available per specification.

      D. Finish: specified finish; factory finished.

      E. Sizes: Modular units fabricated to size by manufacturer as required to fill specified

      areas. Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      F. Fire retardant requirement can be met with the addition of retardant chemicals to the

      resin. Additional information is available for this specification.

      2.3 PLANTER ACCESSORIES

      A. Field installed drainage/irrigation connection fitting. Thread-by-thread thermoplastic

      drainage adapter, ½”, ¾” and 1"NPT female thread available. Contractor to locate drainage

      hole, drill as necessary, and install fitting.

      B. Lifting hooks or stabilizer anchors, quantity, size, and capacity as specified.

      3.0 EXECUTION

      3.1 PREPARATION

      A. Prior to planter or planter liner fabrication, the contractor shall verify as-built dimensions

      of planter area or receptacles to ensure proper size, fit and quantity required.1

      B. Unless planters have drainage fittings as in 2.3.A, drainage holes to be located and made

      by contractor in the field to fit to drainage system.

      3.2 INSTALLATION

      A. Install planter liners to allow for easy removal if necessary.

      B. Provide continuous basal support.

      C. Install liners level to permit adequate drainage and irrigation.

      1 Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can

      lead to delays and additional cost if neglected.

    Tekniske spesifikasjoner
    • Unik ref.bioretention-planters-gfrc
    • ProduktfamilieBioretention Planters
    • ProduktgruppeBioretention GFRC
    • TypeObjekt (enkelt objekt)
    • Utgivelsesdato2024-06-04
    • Utgavenummer1
    Relatert
    • HovedmaterialeMur
    • Designet iUSA
    • Produsert iUSA
    Klassifisering
    • BIMobject kategoriLandskapsutforming - Landskap

    Tilgjengelighet etter region

    Europa Nord Amerika Asia Sør Amerika
    Åland
    Anguilla
    Armenia
    Argentina
    Albania
    Antigua og Barbuda
    Aserbajdsjan
    Bolivia
    Andorra
    Aruba
    Bangladesh
    Brasil
    Belgia
    Bahamas
    Bhutan
    Chile
    Bosnia-Hercegovina
    Barbados
    Brunei
    Colombia
    Bulgaria
    Belize
    Christmas Island
    Ecuador
    Danmark
    Bermuda
    Det britiske territoriet i Indiahavet
    Falklandsøyene (Malvinas)
    Estland
    Canada
    Filippinene
    Fransk Guyana
    Færøyene
    Cayman Islands
    Georgia
    Guyana
    Finland
    Costa Rica
    Hongkong
    Paraguay
    Frankrike
    Cuba
    India
    Peru
    Gibraltar
    Curaçao
    Indonesia
    Surinam
    Guernsey
    Den dominikanske republikk
    Japan
    Uruguay
    Hellas
    Dominica
    Kambodsja
    Venezuela
    Hviterussland
    El Salvador
    Kasakhstan
    Irland
    Grenada
    Kina
    Island
    Grønland
    Kirgisistan
    Isle of Man
    Guadeloupe
    Kokosøyene
    Italia
    Guatemala
    Laos
    Jersey
    Haiti
    Macao
    Kroatia
    Honduras
    Malaysia
    Kypros
    Jamaica
    Maldivene
    Latvia
    Jomfruøyene
    Mongolia
    Liechtenstein
    Jomfruøyene
    Myanmar (Burma)
    Litauen
    Karibisk Nederland
    Nepal
    Luxemburg
    Martinique
    Nord-Korea
    Malta
    Mexico
    Pakistan
    Moldova
    Montserrat
    Singapore
    Monaco
    Nicaragua
    Sør-Korea
    Montenegro
    Panama
    Sri Lanka
    Nederland
    Puerto Rico
    Tadsjikistan
    Nord-Makedonia
    Saint Kitts og Nevis
    Taiwan
    Norge
    Saint Lucia
    Thailand
    Østerrike
    Saint Pierre og Miquelon
    Turkmenistan
    Polen
    Saint Vincent og Grenadinene
    Usbekistan
    Portugal
    Saint-Barthélemy
    Vietnam
    Romania
    Saint-Martin
    Russland
    Sint Maarten
    San Marino
    Trinidad og Tobago
    Serbia
    Turks- og Caicosøyene
    Slovakia
    USA
    Slovenia
    Spania
    Storbritannia
    Svalbard og Jan Mayen
    Sveits
    Sverige
    Tsjekkia
    Tyskland
    Ukraina
    Ungarn
    Vatikanstaten