Lead Free* Double Check Valve Assemblies - Small Diameter - LF850 Small, LF850U Small
Lead Free* Double Check Valve Assemblies - Small Diameter - LF850 Small, LF850U Small
    Febco

    Lead Free* Double Check Valve Assemblies - Small Diameter - LF850 Small, LF850U Small

    Series LF850 Small double check valve assembly backflow preventers includes a freeze sensor for use with SentryPlus Alert® technology to signal when temperature nears the freezing point. Activated by an add-on connection kit, the sensor triggers alerts to help facility personnel reduce equipment damage and repair that may result from cold weather conditions. Available for building and irrigation management systems.

    This series is designed to prevent the backflow of polluted water from entering the potable water supply due to backsiphonage and or backpressure. Features lead free body construction, NPT end connections, top mounted test cocks, and quarter turn ball valve shutoffs.

    Spesifikasjon
    • Features

      • Sensor signals to indicate when temperature nears the freezing point once activated by an add-on BMS/IMS connection kit
      • Compact modular design to facilitate maintenance and in-line repairs with a single access cover
      • In-line serviceable assembly requiring no special tools
      • Two in-line independent positive seating check modules
      • Replaceable seats and seat discs


      Outlet Connection Size

      • 1/2 IN
      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN

      Inlet Connection Type

      • Female Threaded
      • Union Joint

      Inlet Connection Size

      • 1/2 IN
      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN


    Tekniske spesifikasjoner
    • Unik ref.lf850-lf850U-small
    • ProduktfamilieBackflow Prevention
    • ProduktgruppeDouble Check Valve Assemblies
    • TypeObjekt (enkelt objekt)
    • Utgivelsesdato2019-12-03
    • Utgavenummer1
    Relatert
    • HovedmaterialeCast iron
    • Designet iUSA
    • Produsert iUSA
    Klassifisering
    • BIMobject kategoriRørsystem - Ventiler
    • IFC-klassifiseringVentil
    • UNSPSC-navnValves
    • UNSPSC-kode401416
    • Uniclass 2015 kodePr_65_54_95_05
    • Uniclass 2015 beskrivelseBackflow prevention devices
    • CSI MasterFormat 2014 kode40 05 67.13
    • CSI MasterFormat 2014 tittelReduced-Pressure Zone Backflow Preventers for Process Service
    • OmniClass-nummer23-27 31 11
    • OmniClass-tittelBackflow Preventors
    • CSI UniFormat II kodeD20
    • CSI UniFormat II tittelPLUMBING

    Tilgjengelighet etter region

    Nord Amerika
    Canada
    USA