Recycling Duo / Trio Chute, Stainless Steel Door

Recycling Duo / Trio Chute, Stainless Steel Door

4.4 out of 5 stars4.4(5 reviews)

CHUTE MATERIAL

Chutes handling general household or office waste, trash and recycling should be made of a minimum thickness of 16 ga. aluminized steel or stainless steel.

INTAKE DOORS

Duo Chute door is 27" wide by 18" high. Trio Chute door is 36" wide by 18" high. Both are hand operated hopper type intake doors, self- closing, self-latching, noiseless, bottom-hinged with 1-1/2 hour ‘UL’ label; maximum 30-minute 250°F temperature rise. Entire patented door (front & back panels and skirt) in stainless steel finish with ADA compliant lever handle with lock and two keys. Doors are engineered, machined and assembled with no welds. MEA Labeled for New York City.

INTAKE DOOR OPENINGS

The Duo Chute has a 10" wide recycling opening and a 17" wide trash opening. The Trio Chute has a 10" wide recycling ‘A’ opening, a 16" trash ‘C’ opening and a 10" recycling ‘B’ opening.

ROUGH FLOOR OPENINGS

The Duo Chute requires a rough floor opening of 29"x 29". The Trio Chute requires a rough floor opening of 40"x 29".

DISCHARGE

The Accordion Fire Damper spring loaded discharge bears a 1-1/2 hour ‘UL’ label and is held open by a 165° fusible link assembly. This discharge is intended to provide smoke and fire protection to the chute riser and is not designed to perform as a shut off gate.

VENT

Full size vent, made of 100% heavy gauge aluminum to eliminate rusting and improve appearance, extending minimum of 3' (per NFPA) above roof with flashing and metal safety cap.

FLOOR FRAMES

Standard floor frames are 1-1/2" x 1-1/2" x 1/4" steel angle 12" longer than the chute length.

STANDARD ACCESSORIES

1/2" NPT sprinkler and 3/4" NPT flushing heads above top intake. Additional 1/2" sprinkler heads at alternate intakes and at first intake as required by NFPA82 code.

CHUTE CONSTRUCTION

Chute sections shall be factory assembled with all seams fully welded. There shall be a minimum of one expansion joint per floor and a flush interior assembled without bolts, rivets or clips. The intake door and frame shall be securely fastened to the intake throats that are formed as an integral part of the chute section. Chute throats shall have a standard dimension of 10" in length. Larger throats can be built to accommodate special job conditions. Chute shall be straight and plumb with no offset.

Tekniske spesifikasjoner
  • Unik ref.chutes_recycling-chute
  • ProduktfamilieRefuse Disposal Chutes
  • ProduktgruppeInternal Chutes
  • TypeObjekt (enkelt objekt)
  • Utgivelsesdato2017-01-13
  • Utgavenummer1
Relatert
  • Designet iUSA
  • Produsert iUSA
Klassifisering
  • BIMobject kategoriLandskapsutforming - Avfall og resirkulering

Tilgjengelighet etter region

Europa Asia Nord Amerika Afrika Sør Amerika Oceania
Åland
Afghanistan
Anguilla
Algerie
Argentina
Amerikansk Samoa
Albania
Armenia
Antigua og Barbuda
Angola
Bolivia
Australia
Andorra
Aserbajdsjan
Aruba
Benin
Brasil
Cookøyene
Belgia
Bahrain
Bahamas
Botswana
Chile
Fiji
Bosnia-Hercegovina
Bangladesh
Barbados
Burkina Faso
Colombia
Fransk Polynesia
Bulgaria
Bhutan
Belize
Burundi
Ecuador
Guam
Danmark
Brunei
Bermuda
Den demokratiske republikken Kongo
Falklandsøyene (Malvinas)
Kiribati
Estland
Christmas Island
Canada
Den sentralafrikanske republikk
Fransk Guyana
Marshalløyene
Færøyene
De forente arabiske emirater
Cayman Islands
Djibouti
Guyana
Mikronesiaføderasjonen
Finland
Det britiske territoriet i Indiahavet
Costa Rica
Egypt
Paraguay
Nauru
Frankrike
Filippinene
Cuba
Ekvatorial-Guinea
Peru
New Zealand
Gibraltar
Georgia
Curaçao
Elfenbenskysten
Surinam
Niue
Guernsey
Hongkong
Den dominikanske republikk
Eritrea
Uruguay
Nord-Marianene
Hellas
India
Dominica
Eswatini
Venezuela
Norfolkøyene
Hviterussland
Indonesia
El Salvador
Etiopia
Ny-Caledonia
Irland
Irak
Grenada
Gabon
Øst-Timor
Island
Iran
Grønland
Gambia
Palau
Isle of Man
Israel
Guadeloupe
Ghana
Papua Ny-Guinea
Italia
Japan
Guatemala
Guinea
Pitcairn
Jersey
Jemen
Haiti
Guinea-Bissau
Salomonøyene
Kroatia
Jordan
Honduras
Kamerun
Samoa
Kypros
Kambodsja
Jamaica
Kapp Verde
Tokelau
Latvia
Kasakhstan
Jomfruøyene
Kenya
Tonga
Liechtenstein
Kina
Jomfruøyene
Komorene
Tuvalu
Litauen
Kirgisistan
Karibisk Nederland
Kongo
United States Minor Outlying Islands
Luxemburg
Kokosøyene
Martinique
Lesotho
Vanuatu
Malta
Kuwait
Mexico
Liberia
Wallis og Futuna
Moldova
Laos
Montserrat
Libya
Monaco
Libanon
Nicaragua
Madagaskar
Montenegro
Macao
Panama
Malawi
Nederland
Malaysia
Puerto Rico
Mali
Nord-Makedonia
Maldivene
Saint Kitts og Nevis
Marokko
Norge
Mongolia
Saint Lucia
Mauritania
Østerrike
Myanmar (Burma)
Saint Pierre og Miquelon
Mauritius
Polen
Nepal
Saint Vincent og Grenadinene
Mayotte
Portugal
Nord-Korea
Saint-Barthélemy
Mosambik
Romania
Oman
Saint-Martin
Namibia
Russland
Pakistan
Sint Maarten
Niger
San Marino
Palestina
Trinidad og Tobago
Nigeria
Serbia
Qatar
Turks- og Caicosøyene
Réunion
Slovakia
Saudi-Arabia
USA
Rwanda
Slovenia
Singapore
Sankt Helena
Spania
Sør-Korea
São Tomé og Príncipe
Storbritannia
Sri Lanka
Senegal
Svalbard og Jan Mayen
Syria
Seychellene
Sveits
Tadsjikistan
Sierra Leone
Sverige
Taiwan
Somalia
Tsjekkia
Thailand
Sør-Afrika
Tyskland
Turkmenistan
Sør-Sudan
Ukraina
Tyrkia
Sudan
Ungarn
Usbekistan
Tanzania
Vatikanstaten
Vietnam
Togo
Tsjad
Tunisia
Uganda
Vest-Sahara
Zambia
Zimbabwe