Model 5100A COLLECTanDRAIN - Auxiliary Drain with alarm, complete assembly

Model 5100A COLLECTanDRAIN - Auxiliary Drain with alarm, complete assembly

Improve your building's appearance, meet NFPA Code, and pro-actively deter improper maintenance and vandalism

Auxiliary drains often become targets for vandals, since most auxiliary drains do not provide standard protection against tampering. The COLLECTanDRAIN® M5100 and M5200 provide a consistent and clean appearance, and they feature our Patented Anti-Trip Plate that only allows one valve to be open at a time so sprinkler systems cannot be tripped by improper maintenance or vandalism.

The COLLECTanDRAIN® M5100 and M5200 both use the M5300 as the base of their design covered by our Patented Anti-Trip Plate. Our Anti-Trip Plates meet NFPA signage requirements and feature a signal red, powdercoat finish for added durability against weathering. The M5100 features a M5100ALBV Water Detector and Alarm that emits a visual and audible warning when the unit needs servicing.

Spesifikasjon
  • SPRINKLER SPECIALTY PIPE FITTINGS
    Auxiliary Drain and Condensation Collecting Assemblies for Dry Pipe and Preaction Sprinkler Systems:

    1. Manufacturers:  Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:
      1. AGF Manufacturing Inc.; Model 5100A COLLECTanDRAIN™.
      2. Insert manufacturer's name
    2. Standards:
      1. NFPA 13 & NFPA 25.
    3. Material:  Black Steel or Galvanized Pipe Auxiliary Drain with Anti-Trip Plate and Water Detector
    4. Components:
      1. 1 inch MIPT x FIPT Brass quarter turn ball valve with chrome plated ball.
      2. 1 inch MIPT x FIPT Ball Valve with Side Ports.
        1. Water Detection Alarm with Brass Nipple.
        2. Powered by a 9-volt battery to operate a red LED visual indicator and an over 92 dB beeping alarm which are activated when water is present in the COLLECTanDRAIN™.
        3. Battery operated system provides multiple years of service for intermittent alarming or can operate continuously for 72 hours. Unit will provide low battery power indication through audible chirp and yellow LED visual indicator.
        4. Device may be optionally hardwired to a 12 to 24 VDC power source.
        5. Unit features a test button to confirm operational integrity, offers left or right side installation, and can be isolated for service or battery replacement.
        6. Unit may be configured to alarm only when temperature is below 45°F or at any temperature.
        7. Device may be wired to provide remote notification with NO and NC terminals.
      3. Anti-Trip Plate (ATP):  Prevents the opening of either the upper or lower drain valve unless the opposite valve is in the correct closed position, preventing an accidental/malicious tripping of the alarm valve and filling of the sprinkler system.
        1. ATP is powder coated safety red for corrosion resistance and silk-screened with both “AUXILIARY DRAIN” and operating instructions.
        2. ATP can be locked to prevent tampering.
      4. Anti-Trip Plate Mounting Hardware Set.
      5. Two 1 inch by 2 inch (25 mm by 51 mm) Bell Reducer.
      6. 2 inch by 12 inch long (51 mm by 305 mm) Condensate Nipple.
      7. 1 inch (25 mm) Galvanized Square Head Plug.
Tekniske spesifikasjoner
  • Unik ref.agf-model-5100a
  • ProduktfamilieAGF Fire Sprinkler Products
  • ProduktgruppeCOLLECTanDRAIN
  • TypeObjekt (enkelt objekt)
  • Utgivelsesdato2019-10-18
  • Utgavenummer1
Relatert
  • HovedmaterialeKarbonstål
  • Sekundært materialemessing
  • Designet iUSA
  • Produsert iUSA
Klassifisering
  • BIMobject kategoriBrannprodukter - Sprinklersystemer
  • IFC-klassifiseringVentil
  • UNSPSC-navnControl valves
  • UNSPSC-kode40141609
  • Uniclass 2015 kodePr_65_54_24
  • Uniclass 2015 beskrivelseDrainage valves
  • CSI MasterFormat 2014 kode23 09 13.33
  • CSI MasterFormat 2014 tittelControl Valves
  • OmniClass-nummer23-27 31 00
  • OmniClass-tittelValves

Tilgjengelighet etter region

Asia Europa Afrika Sør Amerika Oceania Nord Amerika
Afghanistan
Albania
Algerie
Argentina
Australia
Bahamas
Armenia
Belgia
Angola
Bolivia
Fiji
Belize
Aserbajdsjan
Bosnia-Hercegovina
Benin
Brasil
New Zealand
Canada
Bangladesh
Bulgaria
Botswana
Chile
Ny-Caledonia
Costa Rica
Bhutan
Danmark
Burkina Faso
Colombia
Øst-Timor
Cuba
De forente arabiske emirater
Estland
Burundi
Ecuador
Papua Ny-Guinea
Den dominikanske republikk
Filippinene
Finland
Den demokratiske republikken Kongo
Falklandsøyene (Malvinas)
Salomonøyene
El Salvador
Georgia
Frankrike
Den sentralafrikanske republikk
Fransk Guyana
Vanuatu
Grønland
India
Hellas
Djibouti
Guyana
Guatemala
Indonesia
Hviterussland
Egypt
Paraguay
Haiti
Irak
Irland
Ekvatorial-Guinea
Peru
Honduras
Iran
Island
Elfenbenskysten
Surinam
Jamaica
Israel
Italia
Eritrea
Uruguay
Mexico
Japan
Kroatia
Eswatini
Venezuela
Nicaragua
Jemen
Kypros
Etiopia
Panama
Jordan
Latvia
Gabon
Puerto Rico
Kambodsja
Litauen
Gambia
USA
Kasakhstan
Luxemburg
Ghana
Kina
Moldova
Guinea
Kirgisistan
Montenegro
Guinea-Bissau
Kuwait
Nederland
Kamerun
Laos
Nord-Makedonia
Kenya
Libanon
Norge
Kongo
Malaysia
Østerrike
Lesotho
Mongolia
Polen
Liberia
Myanmar (Burma)
Portugal
Libya
Nepal
Romania
Madagaskar
Nord-Korea
Russland
Malawi
Oman
Serbia
Mali
Pakistan
Slovakia
Marokko
Palestina
Slovenia
Mauritania
Qatar
Spania
Mosambik
Saudi-Arabia
Storbritannia
Namibia
Sør-Korea
Svalbard og Jan Mayen
Niger
Sri Lanka
Sveits
Nigeria
Syria
Sverige
Rwanda
Tadsjikistan
Tsjekkia
Senegal
Taiwan
Tyskland
Sierra Leone
Thailand
Ukraina
Somalia
Turkmenistan
Ungarn
Sør-Afrika
Tyrkia
Sør-Sudan
Usbekistan
Sudan
Vietnam
Tanzania
Togo
Tsjad
Tunisia
Uganda
Vest-Sahara
Zambia
Zimbabwe