Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK
Model 8611 Corner RiserPACK

    Model 8611 Corner RiserPACK

    4.6 out of 5 stars4.6(12 reviews)

    AGF's commercial RiserPACK Model 8611 is a riser manifold for NFPA 13 fire sprinkler systems and is designed to fit into a corner to minimize protruding and comply with ADA Standards. Model 8611 includes a flow switch, TESTanDRAIN Model 1011A with included pressure relief valve and trim, Model 7600 3-way universal gauge valve, and a Model 7500 pressure gauge. Available with a steel body in sizes 2"-6", orifice sizes 3/8" (K 2.8) - 25K, and a groove x groove connection. AGF's corner manifold is available with a right or left drain to accommodate every installation configuration.

    Specificatie
    • Model 8611 Commercial Corner RiserPACK

      1. 2.1 SPRINKLER SPECIALTY PIPE FITTINGS - Flow Detection and Test Assemblies:
        1. Product: Commercial Model M8611. Includes a flow switch, TESTanDRAIN Model 1011A, Model 7600 3-way Globe Valve, and a M7500 Pressure Gauge and a model M7000 Pressure Relief Valve.
          1. Riser Model: Pre-Assembled TESTanDRAIN Riser 2, 2-1/2, 3, 4, and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm):
            1. Inlet and Outlet (Schedule 10 steel): Grooved 2, 2-1/2, 3, 4 and 6 inches (51mm, 64 mm, 76 mm, 102 mm, 152 mm) Models.
            2. Schedule 10 fabricated steel body with 3mil (.08 mm) powder coated red finish.
            3. Standard: UL's "Product iQ" listing, or "Approval Guide," published by FM Global, listing. NFPA 13.
            4. Pressure Rating: 300 psig (2070 kPa).
            5. Size: Same as connected piping.

      ** NOTE TO SPECIFIER ** Delete valve not required.

      1. Valve Model 1011 TESTanDRAIN valve for a 2 inch (51 mm) Model:
        1. 1 inch (25 mm) FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      1. Valve Model 1011 TESTanDRAIN valve for a 4 or 6 inch (102 mm, 152 mm) Models:
        1. 2 inch FNPT.

      ** NOTE TO SPECIFIER ** Delete orifice size not required.

      1. Test Orifice Size: Nominal 2.8K (3/8 inch) , as required by NFPA 13, latest edition.
      2. Test Orifice Size: Nominal 4.2K (7/16 inch), as required by NFPA 13, latest edition.
      3. Test Orifice Size: Nominal 5.6K (1/2 inch), as required by NFPA 13, latest edition.
      4. Test Orifice Size: Nominal 8.0K (17/32 inch), as required by NFPA 13, latest edition.
      5. Test Orifice Size: Nominal 11.2K (5/8 inch, ELO), as required by NFPA 13, latest edition.
      6. Test Orifice Size: Nominal 14.0K (3/4 inch, ESFR), as required by NFPA 13, latest edition.
      7. Test Orifice Size: Nominal 25.2K, as required by NFPA 13, latest edition.
      8. Water flow alarm switch.
      9. Pressure Gauge: AGF Model 7500.
      10. 1/4 inch, 3-way globe valve: AGF Model 7600
      11. Pressure Relief Valve and Drainage Piping: AGF Model 7000 or AGF Lockable Model 7000L

      ** NOTE TO SPECIFIER ** Delete pressure rating not required.

      1. Pressure Rating: Factory rated at 175 PSI.
      2. Pressure Rating: 200 PSI.
      3. Pressure Rating: 225 PSI.
      4. Pressure Rating: 300 PSI.
      5. Body Material: Bronze body and stainless steel spring.
      6. Components: Nylobraid flexible tube, Two 1/2 inch (13 mm) NPT by barbed 90 degree elbows, external identification plate and integral flushing handle to remove debris.
      7. 1/2 inch (13 mm) MIPT inlet, 1/2 inch (13 mm) FIPT outlet.
      8. Relief pressure shall be factory set to project specifications.
      9. Relief valve shall operate to the OPEN position between 90% and 105% of the set pressure.
      10. Relief valve shall reseat or CLOSE at a minimum of 80% of set pressure.
    Technische specificatie
    • Unieke ref.AGF-Corner-Riser
    • ProductfamilieAGF Fire Sprinkler Products
    • ProductgroepRiserPACK®
    • Publicatiedatum2022-03-02
    • Editienummer1
    Gerelateerd
    • HoofdmateriaalStaal met poedercoating
    • Ontworpen inVerenigde Staten
    • Gefabriceerd inVerenigde Staten
    Classificatie
    • Categorie BIMobjectBrandwerende producten - Sproeisystemen
    • CSI MasterFormat 2014 Code21 00 00
    • CSI MasterFormat 2014 TitelFire Suppression
    • OmniClass-nummer23-29 33 00
    • OmniClass-titelFire Suppression System Components
    • CSI UniFormat II-codeD40
    • CSI UniFormat II-titelFIRE PROTECTION

    Beschikbaarheid regio

    Azië Europa Afrika Zuid-Amerika Oceanië Noord Amerika
    Afghanistan
    Albanië
    Algerije
    Argentinië
    Australië
    Bahama's
    Armenië
    België
    Angola
    Bolivia
    Fiji
    Belize
    Azerbeidzjan
    Bosnië en Herzegovina
    Benin
    Brazilië
    Nieuw-Caledonië
    Canada
    Bangladesh
    Bulgarije
    Botswana
    Chili
    Nieuw-Zeeland
    Costa Rica
    Bhutan
    Cyprus
    Burkina Faso
    Colombia
    Oost-Timor
    Cuba
    Cambodja
    Denemarken
    Burundi
    Ecuador
    Papoea-Nieuw-Guinea
    Dominicaanse Republiek
    China
    Duitsland
    Centraal Afrikaanse Republiek
    Falklandeilanden (Islas Malvinas)
    Solomoneilanden
    El Salvador
    Filipijnen
    Estland
    Congo-Brazzaville
    Frans-Guyana
    Vanuatu
    Groenland
    Georgië
    Finland
    Congo-Kinshasa
    Guyana
    Guatemala
    India
    Frankrijk
    Djibouti
    Paraguay
    Haïti
    Indonesië
    Griekenland
    Egypte
    Peru
    Honduras
    Irak
    Hongarije
    Equatoriaal-Guinea
    Suriname
    Jamaica
    Iran
    Ierland
    Eritrea
    Uruguay
    Mexico
    Israël
    IJsland
    eSwatini
    Venezuela
    Nicaragua
    Japan
    Italië
    Ethiopië
    Panama
    Jemen
    Kroatië
    Gabon
    Porto Rico
    Jordanië
    Letland
    Gambia
    Verenigde Staten
    Kazachstan
    Litouwen
    Ghana
    Kirgistan
    Luxemburg
    Guinee
    Koeweit
    Moldavië
    Guinee-Bissau
    Laos
    Montenegro
    Ivoorkust
    Libanon
    Nederland
    Kameroen
    Maleisië
    Noord-Macedonië
    Kenia
    Mongolië
    Noorwegen
    Lesotho
    Myanmar (Birma)
    Oekraïene
    Liberia
    Nepal
    Oostenrijk
    Libië
    Noord-Korea
    Polen
    Madagaskar
    Oezbekistan
    Portugal
    Malawi
    Oman
    Roemenië
    Mali
    Pakistan
    Rusland
    Marokko
    Palestina
    Servië
    Mauritanië
    Qatar
    Slovenië
    Mozambique
    Saudi-Arabië
    Slowakije
    Namibië
    Sri Lanka
    Spanje
    Niger
    Syrië
    Spitsbergen
    Nigeria
    Tadzjikistan
    Tsjechië
    Rwanda
    Taiwan
    Verenigd Koninkrijk
    Senegal
    Thailand
    Wit-Rusland
    Sierra Leone
    Turkije
    Zweden
    Somalië
    Turkmenistan
    Zwitserland
    Sudan
    Verenigde Arabische Emiraten
    Tanzania
    Vietnam
    Togo
    Zuid-Korea
    Tsjaad
    Tunesië
    Uganda
    Westelijke Sahara
    Zambia
    Zimbabwe
    Zuid-Afrika
    Zuid-Soedan