Publiceer je producten
Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y
Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y
    Febco

    Lead Free* Y Pattern Design Reduced Pressure Zone Assemblies - LF825Y

    Series LF825Y Lead Free* Y Pattern Reduced Pressure Zone assemblies feature a flood sensor with SentryPlus Alert® technology to detect excessive water discharges from the relief valve. Activated through an add-on connection kit, the sensor can trigger the alert system sending notification of flood detection to facility personnel. Connection kits are available for BMS and cellular communication.

    This series prevents the reverse flow of contaminated water caused by backsiphonage or backpressure from entering the potable water supply. Ideal for protection at health hazard cross-connections in water services to industrial plants, hospitals, morgues, mortuaries, and chemical plants. Applications also extend to irrigation systems, boiler feeds, water lines, and other installations requiring maximum protection. Maximum working pressure: 175 psi (12.1 bar).

    Specificatie
    • Features

      • Ultimate mechanical protection of potable water against cross-connection contamination of high hazard (toxic) fluids in water services
      • Modular relief valve for ease of maintenance
      • Used in industrial plants, hospitals, morgues, mortuaries, chemical plants, irrigation systems, boiler feed, water lines, and other installations
      • Meets all specifications of AWWA, ASSE, CSA and approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California

      Outlet Connection Size

      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN

      Inlet Connection Size

      • 3/4 IN
      • 1 IN
      • 1 1/4 IN
      • 1 1/2 IN
      • 2 IN
    Technische specificatie
    • Unieke ref.LF825Y-Reduced-Pressure-Zone-Assembly
    • ProductfamilieBackflow Prevention
    • ProductgroepReduced Pressure Zone Assemblies
    • TypeObject (enkelvoudig object)
    • Publicatiedatum2019-05-16
    • Editienummer1
    Gerelateerd
    • HoofdmateriaalBronze
    • Ontworpen inVerenigde Staten
    • Gefabriceerd inVerenigde Staten
    Classificatie
    • Categorie BIMobjectLoodgieterswerk - Kleppen
    • IFC-classificatieKlep
    • UNSPSC-naamValves
    • UNSPSC-code401416
    • Uniclass 2015-codePr_65_54_95_05
    • Uniclass 2015-beschrijvingBackflow prevention devices
    • CSI MasterFormat 2014 Code40 05 67.13
    • CSI MasterFormat 2014 TitelReduced-Pressure Zone Backflow Preventers for Process Service
    • OmniClass-nummer23-27 31 11
    • OmniClass-titelBackflow Preventors
    • CSI UniFormat II-codeD20
    • CSI UniFormat II-titelPLUMBING

    Beschikbaarheid regio

    Noord Amerika
    Canada
    Verenigde Staten