제품 게시
Protan BlueProof Green water attenuation system on concrete substrate
Protan BlueProof Green water attenuation system on concrete substrate
Protan BlueProof Green water attenuation system on concrete substrate
Protan BlueProof Green water attenuation system on concrete substrate
    PROTAN

    Protan BlueProof Green water attenuation system on concrete substrate

    PROTAN BLUEPROOF GREEN WATER ATTENUATION SYSTEM ON CONCRETE SUBSTRATE

    Protan BlueProof is a new and SINTEF-approved (TG 20541) water attenuation system for new and existing roofs (also known as a blue roof). Protan BlueProof Green expands the function of the roof and helps prevent floods and water damage.

    With this system, water is gradually drained and allowed into the storm drain network, avoiding overloading resulting in floods. The system not only solves current problems with storm floods, but also those of the future. Protan can calculate the predicted volumes of water for roofs in specific locations during storm events. Water loads can then be taken into account at an early stage during the building’s construction, ensuring the roof’s structure can retain the calculated water.
    This is often cheaper than utilising other methods of water attenuation.

    Protan BlueProof combines a trusted waterproofing system and a water attenuation system in one. Thus keeping a building’s contents secure whilst reducing the effects of flooding on the surrounding environment.

    Water attenuation calculations are carried out by Protan and are based on the project's location, local authority requirements and the roof's design. Roof slopes can be reduced to 1:100 fall to provide the optimum water attenuation as well as a lower roof profile.

    Protan BlueProof Green system takes the concept a step further by allowing the roof to be utilised further, whether this is a extensive green roof or a roof terrace for recreational use. A void beneath the protection layer allows for a water magazine to build up in the event of a storm.

    Quality assurance of installation
    A Protan BlueProof Roofing System shall always be calculated and planned in detail by Protan AS. The roofing system must be installed by roofing contractors specially approved by Protan AS. Their roofers must have passed "Roofing school" (a certificate containing the relevant basic education in Protan's roofing handbook) and attended Protan BlueProof roofing training.

    All roofs must be undertaken visual inspection done by a person especially appointed by Protan. During the inspection focus shall lie on good melt out along all welding joints on the roof area as well as around details and endings.

    After completing the roof installation, a water flood / pressure test of the roof area has to be carried out, alternatively, verification using electronic leak testing.

    Maintenance
    For Protan BlueProof annual inspection is required to be in front of possible damages. All Protan BlueProof roofs require a maintenance agreement with the building owner. This will ensure qualified inspection and maintenance of the roof and its components up to two times a year during the roofs lifetime.

    CONSTRUCTION STRUCTURE:

    • TERRACE / EXTENSIVE GREEN / SEDUM ROOF LAYERS
    • PROTAN BLUECELL WATER DRAINAGE LAYER
    • PROTECTION MEMBRANE
    • PROTAN BP GREEN
    • PROTAN APPROVED FASTENERS (IF REQUIRED)
    • CONDUCTIVE FELT LAYER
    • INSULATION
    • VAPOUR CONTROL LAYER
    • CONCRETE SUBSTRATE

    PROTAN BP MEMBRANE:

    • Protan BP Green is ca. 1.8 mm thick roofing membrane made of pliable PVC with a core of extra strong polyester reinforcement, which is used in Protan BlueProof Green Roofing System. 
    • Protan BP Green can be used as roofing on different kinds of substrate, but needs a separate glass migration barrier of the quality 120 g/m2 on polystyrene substrates. 
    • Protan BP Green has additional stabilizers to make the membrane resistant to high and low temperatures, ultra violet radiation and atmospheric contamination and to improve safety in case of fire. 
    • Welding of joints is carried out by using hot air. The roofing membranes have an embossed surface that provides an anti-slip texture.

     SYSTEM INSTALLATION METHOD:

    • Protan Standard Overlap System - The membrane is fastened to the substrate along the longitudinal sheet edges and overlapped by the adjoining roll. The two rolls are welded together using hot air.
    • Protan Prefabricated Sheets system is the best and fastest solution in wind-exposed areas, so it is ideal when the roof has to be covered quickly. The membrane is provided in 2 or 4 metre widths with high strength strips welded longitudinally on the underside for mechanical fastening.
    • The Protan Secret Fix System uses a membrane in 2-metre widths with extra strong strips welded transversely to the underside for mechanical fastening.

    Please contact Protan for further advice.

    FASTENERS:

    • Protan approved - must be calculated according to EN 1991-1-4 alongside national annexes and local regulations.

    INSULATION:

    Various types of insulation can be used in combination with Protan membranes and can be flat insulation or sloped insulation. The material type and design will depend on the building design, fire classification and local regulation requirements.

    • Mineral wool (MW) – can be glass or stone type
    • Polyisocyanurate (PIR) - foil faced
    • Combination EPS-MW

    VAPOUR CONTROL LAYER:

    • Polyethylene
    • Bitumen

    CONCRETE SUBSTRATE:

    • Structural concrete as either precast elements or reinforced cast in-situ.
    사양
    • TECHNICAL SPECIFICATION

      Protan BP Green specifications are subject to availability and may not be available or approved in all countries/regions.

      Membrane thickness:

      • ca.1.8 mm (2,1 kg/m2)

      Membrane standard widths: 

      • 1.0 m
      • 2.0 m

      Membrane standard roll lengths: 

      • Made to measure

      Membrane colours (nearest RAL code):

      • Dark grey F94 - RAL 7012 

      FIRE CLASSIFICATION

      Protan BlueProof Green roof systems are classified according to EN 13501-5. Fire classifications are available on a variety of constructions and insulation types. Please contact Protan for further information or refer to the relevant technical approvals.

    기술 사양
    • 특징 참조blueproof_green_concrete_eu
    • 제품군Roofing
    • 제품분류Single Ply Membrane
    • 유형개체 (단일 개체)
    • 게시일2021-07-20
    • 에디션 넘버1
    관련성
    • 주 재료PVC
    • 설계국가노르웨이
    • 제조국가노르웨이
    분류
    • BIMobject 카테고리건축 자재 - Waterproofing & Membranes
    • IFC 분류지붕
    • UNSPSC 이름Roofing membranes
    • UNSPSC 코드30151505
    • Uniclass 2015 코드Ss_30_40_30_80
    • Uniclass 2015 설명Single layer sheet warm roof covering systems
    • CSI 마스터 형식 2014 코드07 50 00
    • CSI 마스터 형식 2014 제목Membrane Roofing
    • OmniClass 번호23-13 39 31 11 27
    • OmniClass 제목Polyvinyl chloride (PVC) Single Layer Roof Membranes
    • CSI 단일 형식 II 코드B3010
    • CSI 단일 형식 II 제목Roof Coverings

    지역 가용성

    유럽 아시아
    건지
    터키
    그리스
    네덜란드
    노르웨이
    덴마크
    독일
    라트비아
    러시아
    루마니아
    뤽상부르
    리투아니아
    리히텐슈타인
    맨섬
    모나코
    몬테네그로
    몰도바
    몰타
    바티칸 시국
    벨기에
    벨로루시
    보스니아 헤르체고비나
    북마케도니아
    불가리아
    산마리노
    세르비아
    스발바르 얀마옌 제도
    스웨덴
    스위스
    스페인
    슬로바키아
    슬로베니아
    아이슬란드
    아일랜드
    안도라
    알바니아
    에스토니아
    영국
    오스트리아
    올란드 제도
    우크라이나
    이탈리아
    저지섬
    지브롤터
    체코 공화국
    크로아티아
    키프러스
    페로 제도
    포르투갈
    폴란드
    프랑스
    핀란드
    헝가리