    仕様
    • UNDER-SLAB VAPOR BARRIER

       PART 1 - GENERAL

       1.1               SUMMARY

      A.          Productssupplied under this section:

      1.           Vapor barrier and installationaccessories for installation under concrete slabs.

      B.          Relatedsections:

      1.                 Section 03 30 00 Cast-in-Place Concrete

      2.                 Section 07 26 00 Vapor Retarders

       1.2        REFERENCES

      A.          AmericanSociety for Testing and Materials (ASTM):

      1.           ASTM E1745-17 Standard Specificationfor Plastic Water Vapor Retarders Used in Contact with Soil or Granular FillUnder Concrete Slabs.

      2.           ASTM E1643-11 Selection, Design,Installation, and Inspection of Water Vapor Retarders Used in Contact withEarth or Granular Fill Under Concrete Slabs.

      B.          TechnicalReference - American Concrete Institute (ACI):

      1.           ACI 302.2R-06 Guide for ConcreteSlabs that Receive Moisture-Sensitive Flooring Materials.

      2.           ACI 302.1R-15 Guide to Concrete Floorand Slab Construction.

       1.3        SUBMITTALS

      A.          Qualitycontrol/assurance:

      1.           Summary of test results per paragraph9.3 of ASTM E1745.

      2.           Manufacturer's samples andliterature.

      3.           Manufacturer's installationinstructions for placement, seaming, penetration prevention and repair, andperimeter seal per ASTM E1643.

      4.           All mandatory ASTM E1745 testing mustbe performed on a single production roll per ASTM E1745 Section 8.1.

       PART 2 - PRODUCTS

      2.1        MATERIALS

                    A.          Vapor barrier shall have all of thefollowing qualities:

      1.           Maintain permeance of less than 0.01Perms [grains/(ft2 ·  hr · inHg)] as tested in accordance with mandatory conditioningtests per ASTM E1745 Section 7.1 (7.1.1-7.1.5).

      2.           Other performance criteria:

      a.           Strength: ASTM E1745 Class A.

      b.           Thickness:  15 mils minimum

      3.           Provide third party documentationthat all testing was performed on a single production roll per ASTM E1745Section 8.1

      B.          Vaporbarrier products:

      1.           Basis of Design: Stego Wrap VaporBarrier (15-mil) by Stego Industries LLC., (877) 464-7834 www.stegoindustries.com.

      2.           No substitutions.

       2.2        ACCESSORIES

      A.          Seams:

      1.           Stego Tape by Stego Industries LLC,(877) 464-7834 www.stegoindustries.com.

      B.          SealingPenetrations of Vapor barrier: 

      1.           Stego Mastic by Stego Industries LLC,(877) 464-7834 www.stegoindustries.com.

      2.           StegoTape by Stego Industries LLC, (877) 464-7834 www.stegoindustries.com.

      C.          Perimeter/edgeseal:

      1.           Stego Crete Claw by Stego IndustriesLLC, (877) 464-7834 www.stegoindustries.com.

      2.           StegoTerm Bar by Stego Industries LLC, (877) 464-7834 www.stegoindustries.com.

      3.           StegoTackTape (double-sided sealant tape) by Stego Industries LLC, (877) 464-7834www.stegoindustries.com.

      D.          PenetrationPrevention:

      1.                 Beast Foot by Stego Industries LLC, (877) 464-7834 www.stegoindustries.com.

      E.           VaporBarrier-Safe Screed System

      1.                 Beast Screed by Stego Industries, LLC, (877) 464-7834www.stegoindustries.com.

        PART 3 - EXECUTION

       3.1        PREPARATION

      A.          Ensurethat subsoil is approved by Architect or Geotechnical Engineer.

      1.           Level and compact base material.

       3.2        INSTALLATION

      A.          Installvapor barrier in accordance ASTM E1643.

      1.           Unroll vapor barrier with the longestdimension parallel with the direction of the concrete placement and face lapsaway from the expected direction of the placement whenever possible.

      2.           Extend vapor barrier to the perimeterof the slab. If practicable, terminate it at the top of the slab, otherwise (a)at a point acceptable to the structural engineer or (b) where obstructed byimpediments, such as dowels, waterstops, or any other site condition requiringearly termination of the vapor barrier. At the point of termination, seal vaporbarrier to the foundation wall, grade beam or slab itself.            

                    [Specifiernote: The perimeter seal can be handled several ways.  When sealing to the slab,

                    Crete Claw is the best option.  When sealing to a stem wall or wall,

                    the best option is to use StegoTack Tape orboth StegoTack Tape and Stego Term Bar.]

      a.           Seal vapor barrier to the entire slabperimeter using Stego Crete Claw, per manufacturer's instructions.

      OR

      b.           Seal vapor barrier to the entireperimeter wall or footing/grade beam with double sided StegoTack Tape, or bothStego Term Bar and StegoTack Tape, per manufacturer's instructions.  Ensure the concrete is clean and dry prior toadhering tape.

      3.           Overlap joints 6 inches and seal withmanufacturer's seam tape.

      4.           Apply seam tape/Crete Claw to a cleanand dry vapor barrier.

      5.           Seal all penetrations (includingpipes) per manufacturer's instructions.

      6.           For interior forming applications,avoid the use of non-permanent stakes driven through vapor barrier.  Use blunt-end and/or threaded nail stakes(screed pad posts) and insert them into Beast Foot. Ensure Beast Foot'speel-and-stick adhesive base is fully adhered to the vapor barrier

      7.           If non-permanent stakes must bedriven through vapor retarder, repair as recommended by vapor retardermanufacturer.

      8.           Use reinforcing bar supports withbase sections that eliminate or minimize the potential for puncture of thevapor barrier.

      9.           Repair damaged areas with vaporbarrier material of similar (or better) permeance, puncture and tensile.

      10.        For vapor barrier-safe concrete screedingapplications, install Beast Screed (vapor barrier-safe screed system) permanufacturer's instructions prior to placing concrete.

       END OF SECTION

    技術仕様
    • Unique refstego002
    • コレクションセットThermal and Moisture Protective Products
    • コレクションStego Wrap
    • タイプオブジェクト(1つのオブジェクト)
    • 公開日2019-02-01
    • エディション2
    関連
    • 主なマテリアルポリエチレン
    • 設計国アメリカ合衆国
    • 製造国アメリカ合衆国
    識別情報
    • BIMobjectカテゴリ建築資材 - 防水・耐水材
    • MasterFormat 2014 コード07 26 00
    • MasterFormat 2014 タイトルVapor Retarders

    対応地域

    北米 オセアニア 南アメリカ
    アメリカ合衆国
    オーストラリア
    チリ
    アメリカ領ヴァージン諸島
    ニュージーランド
    ペルー
    アルバ
    アングィラ
    アンティグア・バーブーダ
    イギリス領バージン諸島
    エルサルバドル
    カナダ
    キューバ
    キュラソー島
    グアテマラ
    グアドループ
    グリーンランド
    グレナダ
    ケイマン諸島
    コスタリカ
    サン・バルテルミー島
    サン・マルタン
    サンピエール島・ミクロン島
    ジャマイカ
    シント・マールテン
    セントクリストファー・ネービス
    セントビンセントおよびグレナディーン諸島
    セントルシア
    タークス・カイコス諸島
    ドミニカ
    ドミニカ共和国
    トリニダード・ドバゴ
    ニカラグア
    ハイチ
    パナマ
    バハマ
    バミューダ諸島
    バルバドス
    プエルトリコ
    ベリーズ
    ボネール、シント・ユースタティウスおよびサバ
    ホンジュラス
    マルティニーク
    メキシコ
    モントセラト