洗面台用の隠しデジタル混合バルブは、非接触式の流量と温度制御、プログラム可能な最大温度、最小温度、デフォルト温度、データ ロギング機能を備えたデューティ フラッシュと熱消毒を提供します。別の注ぎ口が必要です。補足製品を参照してください。プログラム可能な最大温度、最小温度、デフォルト温度、デューティ フラッシュ、およびデータ ロギング機能を備えた熱消毒を提供するデジタル混合バルブ。
仕様
  • Product Reference

    Rada Washbasin T3 (1.1503.678)

    Rada Washbasin Kit T3 (1.1503.702)

    Standard product features

    Washbasin T3:

    A concealed digital mixing valve for washbasins, supplied complete with programmable software, power supply, check valves and strainers.

    The system incorporates a wall mounted control panel offering infra-red 'no-touch' controls for flow and temperature adjustment and programmable timed flow control.

    Washbasin Kit T3:

    Specification as above but with wall mounted spout with 150 mm throw, supplied with a 5 litres/minute flow regulator.

    Operation:

    • Temperature selector: Full 'no-touch' temperature control.

    • Flow control: No-touch on/off.

    A Pocket PC is required to adjust factory settings, retrieve data, configure duty flush and disinfection cycles. The programmer software supplied is designed to run on Microsoft Pocket PC 2002 and Microsoft Windows Mobile (for pocket PC's).

    Materials:

    • Control panel cover: Chrome plated ABS.

    • Mixing unit enclosure: PC/ABS.

    • Integral components: DZR brass, stainless steel and engineering plastic.

    Temperature Range

    • Factory pre-set minimum temperature: 30ºC.

    • Factory pre-set maximum temperature: 41ºC.

    • Default temperature: 38ºC.

    • Minimum blend temperature differential from hot supply: 2ºC.

    • Optimum thermostatic control range: 30ºC to 50ºC.

    • Cold water range: 1ºC to 20ºC.

    • Hot water range: 50ºC to 65ºC (85ºC during disinfection).

    Programmable Temperature Range

    • Minimum temperature: 30ºC to 47ºC.

    • Maximum temperature: 33ºC to 50ºC.

    • Default temperature: 30ºC to 50ºC.

    Pressure:

    • Maximum static pressure: 10 bar.

    • Minimum pressure loss: 0.2 bar.

    • Hot and cold pressure should be nominally equal. (Maximum differential either way 3:1).

    Flow rate:

    • Minimum flow rate: <5 bar: maintained pressure 4 litres/minute.

    • >5 bar: maintained pressure 6 litres/minute.

    Environment:

    • Ambient temperature: 1°C to 40°C.

    • Maximum relative humidity: 95% non-condensing.

    IP rating:

    • Control panel: IP47.

    • Overall valve enclosure: IP24.

    • Electronics compartment: IP45.

    • PSU: IP45.

    Electrical:

    • Supply voltage: 100-240V RMS 50-60Hz

    • Maximum load: 20W at 12V DC.

技術仕様
  • Unique refRada-Sense---Washbasin-T3
  • コレクションセットSanitary
  • コレクションWash Basins
  • タイプオブジェクト(1つのオブジェクト)
  • 公開日2022-08-04
  • エディション1
関連
  • 主なマテリアルABS樹脂
  • 副マテリアルPC/ABS
  • 設計国イギリス
  • 製造国イギリス
識別情報
  • BIMobjectカテゴリサニタリー - 洗面器
  • IFC分類オブジェクト
  • Uniclass2015コードPr_65_54_95_88
  • Uniclass2015詳細Thermostatic mixing valves

対応地域

ヨーロッパ
イギリス
オランダ
ドイツ
ベルギー