製品の公開
Commercial Indoor/Outdoor Tankless Water Heater
Commercial Indoor/Outdoor Tankless Water Heater
    A. O. Smith

    Commercial Indoor/Outdoor Tankless Water Heater

    4.3 out of 5 stars4.3(15 reviews)
    Google翻訳”,

    最高の機能を備えた凝縮技術を備えた超低NOxガスタンクレス給湯器
    0.95運用コストを削減し、環境に配慮した均一エネルギー係数(UEF)
    フレンドリー。



    仕様
    • TANKLESS CONDENSING HIGH EFFICIENCY SPECIFICATIONS

      The fully modulating, on-demand, condensing gas fired tankless water heater(s) shall be A.O. Smith model CT-199, having a maximum input
      rating of 199,000 Btu/h and available in NG or LP. The heater shall have ¾ in. male NPT water and gas connections. The inlet gas supply
      pressures shall be 4.0 in. WC (min.) up to 10.5 in. WC (max) for NG and 8.0 in. WC (min.) up to 14 in. WC (max.) for LP. The indoor heater(s)
      shall incorporate an integrated temperature controller that will provide diagnostic information, fault history, and heater set temperature. The
      outdoor heater(s) shall be factory supplied with a temperature remote, 100112572, that can be installed up to 400 ft. from the heater using
      18 gauge (minimum) control wire. The temperature remote shall provide diagnostic information, fault history, and heater set temperature. The
      heater(s) shall operate using 120 V / 60 Hz power source. The indoor heater(s) will incorporate a factory installed power cord.
      The indoor heater(s) shall be vented with 3” or 4” diameter schedule 40 PVC, CPVC, ABS, or Category IV vent pipe with a length not to exceed
      70 ft. (equivalent) for 3” vent or 100 ft. (equivalent) for 4” vent, terminating horizontally or vertically. The intake pipe may use material such
      as PVC, ABS, aluminum, or Category IV pipe and cannot exceed 70 ft. (equivalent) for 3” vent or 100 ft. (equivalent) for 4” vent. The outdoor
      heater(s) shall be constructed with an integral exhaust vent on the front of the heater.
      The water heater(s) shall use a commercial-grade copper, fin tube primary heat exchanger with quick release brass or bronze waterways. The
      secondary heat exchanger shall be constructed from stainless steel 316L. The heater(s) shall be controlled by an on-board solid-state printed
      circuit board which uses the following factory installed components: thermistors to monitor water temperature and exhaust temperature; a flow
      sensor to measure flow rate; a flame sensor to monitor combustion; an Air-Fuel Ratio Rod to measure and adjust air input in order to maintain
      optimal combustion efficiency. The heater also consists of in-line fusing and surge absorbers for electrical surge protection, an electronic spark
      igniter, aluminized stainless steel burners, hi-limit temperature switches to monitor water and exhaust temperatures, modulating gas valve,
      dual freeze protection that will automatically fire the heater (indoor model only) and use heating blocks to protect the heat exchanger, and an
      overheat cutoff fuse.
      The heater(s) can manifold to Easy-Link up to 4 heaters to provide additional capacity. The Easy-Link controls shall be built onto the on-board
      solid state printed circuit board and does not require external controls. The linking control wire shall be supplied with the heater. The heater(s)
      can use a Multi-Unit controller, 100112691, to manifold 5-20 heaters. The Easy-Link and Multi-Unit Controller shall modulate the system for the
      most efficient performance. The Easy-Link and Multi-Unit Controller shall rotate the priority heater every 12 hours of operation time or 100 starts
      for balanced duty/cycle operation.
      The heater models are design certified by CSA according to ANSI Z21.10.3 · CSA 4.3, approved for sale in the United States, ENERGY STAR®
      qualified, has a minimum uniform energy factor of 0.93, meets the energy efficiency requirements of the U. S. Department of Energy and ASHRAE
      90.1, complies with SCAQMD Rule 1146.2 and other air quality districts with similar requirements for low NOx emissions of 14 ng/J or 20 ppm,
      and shall be certified to NSF 5 standards.

    技術仕様
    • Unique refaosmith_CT-199
    • コレクションセットCommercial Tankless Water Heater
    • コレクションTankless
    • タイプオブジェクト(1つのオブジェクト)
    • 公開日2019-10-18
    • エディション1
    関連
    • 主なマテリアル
    • 副マテリアルステンレス
    • 設計国日本
    • 製造国日本
    識別情報
    • BIMobjectカテゴリHVAC - 温水器
    • ETIM コードEC000392
    • ETIM 名Instantaneous water heater
    • Uniclass2015コードPr_60_60_96_33
    • Uniclass2015詳細Gas-fired instantaneous water heaters
    • MasterFormat 2014 コード22 34 13
    • MasterFormat 2014 タイトルInstantaneous, Tankless, Gas Domestic Water Heaters
    • OmniClassNumber23-31 29 11 13
    • OmniClassタイトルGas Instantaneous Hot Water Heaters
    • UniFormatIIコードD3090
    • UniFormatIIタイトルOther HVAC Systems & Equipment

    対応地域

    北米
    アメリカ合衆国
    アメリカ領ヴァージン諸島
    アルバ
    アングィラ
    アンティグア・バーブーダ
    イギリス領バージン諸島
    エルサルバドル
    カナダ
    キューバ
    キュラソー島
    グアテマラ
    グアドループ
    グリーンランド
    グレナダ
    ケイマン諸島
    コスタリカ
    サン・バルテルミー島
    サン・マルタン
    サンピエール島・ミクロン島
    ジャマイカ
    シント・マールテン
    セントクリストファー・ネービス
    セントビンセントおよびグレナディーン諸島
    セントルシア
    タークス・カイコス諸島
    ドミニカ
    ドミニカ共和国
    トリニダード・ドバゴ
    ニカラグア
    ハイチ
    パナマ
    バハマ
    バミューダ諸島
    バルバドス
    プエルトリコ
    ベリーズ
    ボネール、シント・ユースタティウスおよびサバ
    ホンジュラス
    マルティニーク
    メキシコ
    モントセラト