Composition
- Protective film
- Decolative layer
- Noncombustible core layer
Specifications
- Only one side (the side covered with a protective film) of Cerarl products is decorative.
- Used for wall surfaces, but the underside is not sanded as standard.
- If you require sanding, please add an "S" at the end of the item number when ordering.
.Maintenance
- To remove dirt from the surface, use moistened melamine foam(melamine sponge) or wipe away the dirt with a soft cloth dabbed in a neutraldetergent. Be sure to use a dry cloth to wipe away the moisture. Do not use anylon scrub brush, steel wool, or abrasive detergent.
Storage and Handling
- Avoid storing directly on the ground or concrete floors, but store flaton palettes. (Please be sure to stack flat to prevent warping.)
- Do not place objects on to the stack or step on top of it.
- Do not store near rainwater or places exposed to moisture, direct sunlight,or extremely low or high temperatures.
- Do not stack upright. Doing so may cause warping.
[NOTE]
Cerarl Panels for Hospital Operating Room - 935x2455mm & 1235x3080mm