Pubblica i tuoi prodotti
Wilshire Planters, FRP with Greenscreen Trellis
Tournesol

Wilshire Planters, FRP with Greenscreen Trellis

Wilshire Planters, FRP with Greenscreen® trellis

An attractive, easy-to-install solution for creating privacy or hiding unattractive elements like building systems. Our lightweight FRP Fiberglass planter (available in all colors and textures) and Greenscreen® trellis, are framed on top and sides, with vertical supports to fit in planter lip. Trellis available in various powder-coat colors.

  • Durable, lightweight FRP planter with powder-coated Greenscreen® trellis. 2” W x 2” L x 3” D grid.
  • Trellis vertical supports fit into planter lip and are secured with discrete stainless-steel fasteners.
  • Trellis is framed on top and sides and extends to planter edge so adjacent planters form a seamless trellis wall.
  • Select a Greenscreen® Trellis color in addition to a GFRC color and texture. Drain holes are available upon request.

As a product manufacturer, Greenscreen supports the commitment and vision of design professionals to incorporate low-impact, environmentally sensitive building practices and promote sustainable design principles by providing critical reviews of credit contributions to the LEED and SITES™ programs including a downloadable Recycled Content Declaration.

Voce di capitolato
  • G U I D E S P E C I F I C A T I O N
    Guide Specification 32 94 50 – 5 [WELDED WIRE PANEL
    Greenscreen PLANT SUPPORT SYSTEM]
    PART 2 - PRODUCTS
    2.1 SUSTAINABILITY CHARACTERISTICS
    A. The welded wire panel plant support system and accessories shall have completed an ISO
    Compliant 14040/44, third party verified Life Cycle Assessment (LCA).
    2.2 ACCEPTABLE MANUFACTURER
    A. Greenscreen, 725 S. Figueroa St. Suite 1825, Los Angeles, CA 90017; Tel: 1-800-450-3494;
    sales@greenscreen.com, www.greenscreen.com.
    2.3 PANELS
    A. Panels shall be rigid, three dimensional welded wire grid fabricated of 14 gage galvanized steel
    wire.
    1. Metallic-Coated Steel Wire: Welded-wire, galvanized in accordance with ASTM A641.
    B. Face Grid: Wires shall be welded at each intersection to form a 2 x 2 inch face grid on the front
    and back of panels,
    C. Trusses: Face grids shall be separated by bent wire trusses spaced at 2-inch centers and welded
    to front and back face grids at each truss apex.
    D. Thickness: [3 inches.] [As shown on Drawings.]
    E. Length and Width: As indicated on the Drawings.
    F. Tolerance: 1/8 inch in width and 1/8 inch in length.
    2.4 ACCESSORIES
    A. Trim:
    1. Fabricate from 20-gage ASTM A879 galvanized steel.
    2. Types:
    a. Channel Trim: Thickness of panel x ½ inch legs.
    b. Angle Trim: ½ inch x ½ inch legs.
    3. Locations:
    a. As indicated on the Drawings.
    B. Clips and Straps: Provide manufacturer’s standard types of clips and straps suitable for mounting
    conditions. Fabricate from ASTM A879 galvanized steel. Adjustable clips shall have ¼ inch
    diameter 18-8 stainless steel bolt, washer, and nut.
    G U I D E S P E C I F I C A T I O N
    Guide Specification 32 94 50 – 6 [WELDED WIRE PANEL
    Greenscreen PLANT SUPPORT SYSTEM]
    C. Plastic Spacers: Provide ½ inch thick black Ultra High Molecular Weight polyethylene (UHMW)
    washers [to hold clips away from mounting surface].
    D. Fence Posts: 3-inch [2-7/8” OD ASTM A500] [square ASTM A500, Grade B] steel tube. The
    steel strip used in the manufacture of the post shall conform to ASTM A1011. Minimum yield
    strength shall be 45,000 psi. [Provide steel post caps.] Overall post length shall be as indicated
    on the Drawings.
    E. Fasteners for Mounting Clips to Fence Posts: Self drilling, self tapping hex washer head screws,
    with strength of Type 410 stainless steel, and corrosion resistance of Type 304 stainless steel.
    F. Fasteners for Attachment to Structure Pull Out Value:
    1. To Concrete or Masonry: [480 lbs.].
    2. To Structural Steel: [480 lbs.].
    3. To Light-Gage Steel Framing: [480 lbs.].
    4. To Wood Framing: [480 lbs.].
    G. Planter: [__________________________________________.]
    2.5 FABRICATION
    A. Cut to size.
    B. Weld trim to panels and grind smooth exterior surfaces of welds.
    C. Curved Panels: All curved panels shall be fabricated in the factory using approved “Cut-to-
    Curve” or “Crimped-to-Curve” procedures as recommended by manufacturer for diameter of
    curve and conditions of use prior to application of powder coat finish to ensure that all wire edges
    are coated and protected. The use of “Cut-to-Curve” or “Crimped-to-Curve” fabrication technique
    is dependent on the specific radius and the direction of the curve relative to the flat panel layout.
    2.6 FINISH
    A. Metal components (except fasteners) shall receive commercial grade finish system after
    fabrication.
    B. Finish System:
    1. Pretreat with general purpose, alkaline, water based cleaner / degreaser applied at 240
    degrees F.
    2. Prime with fusion bond epoxy powder coat.
    3. Topcoat with [TGIC] polyester or polyester-urethane powder coat with a minimum total
    dry film thickness of not less than [6 mils (0.15 mm)].
    G U I D E S P E C I F I C A T I O N
    Guide Specification 32 94 50 – 7 [WELDED WIRE PANEL
    Greenscreen PLANT SUPPORT SYSTEM]
    C. Salt Spray Resistance: Finish shall remain rust free when tested 1680 hours in accordance with
    ASTM B117.
    D. Finish and Color: [Textured Green.] [Textured Black.] [Silver.] [Bronze.] [Terra] [Gloss
    White.] [Color selected by [Architect] from manufacturer’s standards.] [RAL [Classic]
    [Design] color [__________].] [Custom color to match [__________].]
    E. Touch-Up Paint: Provide high quality, exterior-grade spray paint suitable for conditions of use.
    2.7 WARRANTY
    A. Standard 1 year warranty is available from the date of substantial completion or 18 months from
    the date of shipment, whichever comes first. Greenscreen warrants against defects in
    workmanship and materials that would result in failure under intended application and use as
    exterior fabricated wall grillage. “Failure” is defined as structural failure of the wire of sufficient
    incidents in any panel that would result in the panel not performing in a structural or safe manner
    under the intended application and use. Installation is excluded. Contact Greenscreen for further
    information, and extensions.
    2.8 MISCELLANEOUS MATERIALS
    A. Concrete: Refer to Section 03 30 00, CAST-IN-PLACE CONCRETE.
    B. Concrete: Normal-weight, air-entrained, ready-mix concrete with a minimum 28-day
    compressive strength of 3000 psi (20 MPa), 3-inch (75-mm) slump, and 1-inch (25-mm)
    maximum aggregate size [ or dry, packaged, normal-weight concrete mix complying with
    ASTM C 387 mixed with potable water according to manufacturer's written instructions].

Specifiche tecniche
  • Rif. Unicowilshire-planters-frp-with-greenscreen-trellis
  • Famiglia di prodottoWilshire Collection
  • Gruppo di famigliaPlanters with Trellis
  • TipoOggetto (oggetto singolo)
  • Data di pubblicazione2023-11-11
  • Numero di versione1
Relativo a
  • Materiale principaleFiberglass
  • Materiale secondarioAcciaio al carbonio
  • Progettato inStati Uniti
  • Prodotto inStati Uniti
Classificazioni
  • Categoria BIMobjectPaesaggio ed esterni - Paesaggio - Altro
  • Numero OmniClass23-11 27 13 17
  • Titolo OmniClassPlanters

Disponibilità Regionale

Europa Nord America Asia Sud America
Albania
Anguilla
Armenia
Argentina
Andorra
Antigua e Barbuda
Azerbaijan
Bolivia
Austria
Aruba
Bangladesh
Brasile
Belgio
Bahamas
Bhutan
Cile
Bielorussia
Barbados
Brunei
Colombia
Bosnia ed Erzegovina
Belize
Cambogia
Ecuador
Bulgaria
Bermuda
Cina
Guiana Francese
Cipro
Canada
Corea del Nord
Guyana
Città del Vaticano
Costa Rica
Corea del Sud
Isole Falkland (Malvine)
Croazia
Cuba
Filippine
Paraguay
Danimarca
Curaçao
Georgia
Perù
Estonia
Dominica
Giappone
Suriname
Finlandia
El Salvador
Hong Kong
Uruguay
Francia
Giamaica
India
Venezuela
Germania
Grenada
Indonesia
Gibilterra
Groenlandia
Isola di Natale
Grecia
Guadalupa
Isole Cocos (Keeling)
Guernsey
Guatemala
Kazakistan
Irlanda
Haiti
Kirghizistan
Islanda
Honduras
Laos
Isola di Man
Isole BES
Macau
Isole Åland
Isole Cayman
Maldive
Isole Faroe
Isole Turks e Caicos
Malesia
Italia
Isole Vergini Americane
Mongolia
Jersey
Isole Vergini britanniche
Myanmar (Burma)
Lettonia
Martinica
Nepal
Liechtenstein
Messico
Pakistan
Lituania
Montserrat
Singapore
Lussemburgo
Nicaragua
Sri Lanka
Macedonia del Nord
Panamá
Tagikistan
Malta
Porto Rico
Tailandia
Moldavia
Repubblica Dominicana
Taiwan
Monaco
Saint Kitts e Nevis
Territori Britannici dell'Oceano Indiano
Montenegro
Saint Martin
Turkmenistan
Norvegia
Saint Vincent e Grenadine
Uzbekistan
Paesi Bassi
Saint-Barthélemy
Vietnam
Polonia
Saint-Pierre e Miquelon
Portogallo
Santa Lucia
Regno Unito
Sint Maarten
Repubblica Ceca
Stati Uniti
Romania
Trinidad e Tobago
Russia
San Marino
Serbia
Slovacchia
Slovenia
Spagna
Svalbard e Jan Mayen
Svezia
Svizzera
Ucraina
Ungheria