Pubblica i tuoi prodotti
Bioretention Planters, GFRC
Bioretention Planters, GFRC
Bioretention Planters, GFRC
    Tournesol

    Bioretention Planters, GFRC

    GFRC - LIGHTWEIGHT CONCRETE

    Our bioretention planters are pre-built and installed on-site to collect stormwater from drain leads/downspouts. Plants and media filter water, removing organic and inorganic solids, and slowly release the water into the storm drains, reducing peak discharge rates.
    We offer a range of standard sizes in both aluminum and GFRC - Glass-fiber reinforced concrete, but most bioretention projects are custom.

    Voce di capitolato
    • Guide Specification

      Section 129300 Site Furnishings
      Section 129200 Interior Planters

      Tournesol Siteworks Fiberglass Planters and Planter Liners

      1.0 GENERAL

      1.1 WORK INCLUDED

      A. Provision of fiberglass planters and planter liners

      1.2 RELATED WORK

      A. Section 033000 Cast-in-Place concrete

      B. Section 061000 Rough Carpentry

      C. Section 062000 Finish Carpentry

      1.3 SUBMITTALS

      A. Product Data: Manufacturer's standard catalog cut sheets.

      B. Samples: As required for color selection or material thickness only.

      C. Shop Drawings: For custom applications, showing critical sizes and dimensions for

      installation and integration with other work.

      1.4 DELIVERY, STORAGE AND HANDLING

      A. Unwrap and inspect planters and planter liners after delivery for signs of damage during

      transit.

      B. Protect planters and planter liners from damage during storage and handling.

      C. Store planters and planter liners indoors if possible. Do not stand or walk on planters or

      planter liners.

      1.5 PROJECT CONDITIONS

      A. Contractor to provide adequate structural support for planter liner units. Unless

      otherwise specified, planters and liners should have continuous basal support.

      B. Protect units from damage by adjacent work.

      2.0 PRODUCTS

      2.1 ACCEPTABLE PRODUCTS/MANUFACTURERS

      A. Fiberglass Planters and planter liners, manufactured by Tournesol Siteworks LLC. 30955

      San Antonio St., Hayward, CA 94544 Tel: (800) 542-2282 FAX (510) 471-6243

      2.2 FIBERGLASS PLANTERS AND PLANTER LINERS

      A. Materials - All parts shall be constructed of glass fiber-reinforced polyester resin, using

      either the hand-layup or spray-layup methods.

      1. Glass fibers shall be PPG or equivalent. For hand layup fibers should be uniform

      chopped strand mat, minimum 3 oz. density. Smaller round containers will use one layer

      of mat (or spray equivalent), smaller squares and larger round containers must use two

      layers (or spray equivalent), larger square and rectangular containers must use min. 3

      layers (or spray equivalent).

      2. Polyester resin shall be compounded by a reputable manufacturer. All planters and

      planter liners will be fabricated of 100% resin – inorganic fillers will not be acceptable.

      3. Gel coating (where necessary) shall be of specified color. Metallic finishes will use

      atomized metal thoroughly blended with polyester resin, and applied over clean surfaces.

      4. Painted finishes will be made of polyurethane low VOC (less than 2.8 VOC) enamel

      with excellent corrosion and chemical resistance by PPG (AUE 280) or equivalent.

      B. Construction

      Architectural parts shall be fabricated by hand-layup, spray laminate, or resin transfer

      method using suitable molds to attain the desired surface finish. The finished reinforced

      plastic material shall be not less than 5/32" thick and thicker in those areas requiring

      additional structural strength.

      Where ribs or stiffeners are to be fastened to liner sections by spray laminating over

      premolded forms, the stiffeners or ribs shall be located and spray laminated into position so

      that the finished joint shall conform to performance specifications below.

      For vertical surface reinforcement, an inorganic honeycomb strengthening layer using

      double-veiled, bonded material shall be located and hand- or spray-laminted into position

      prior to the wall material setting. The entire honeycomb panel must be subject to pressure

      during curing to ensure proper bonding to wall. Honeycomb thickness will be minimum

      ¼”, or thicker as required for larger spans. Marine-grade plywood may be substituted for

      bottom panels to be penetrated with drainage or irrigation holes.

      Interior of planter or planter liner to be waterproofed with additional layer of black gel

      coating, additional waterproofing available as specified.

      C. Performance characteristics and capacities, finished product to yield the following

      minimum performances:

      Hardness, Barcol 50

      Tensile Strength, Ultimate 12500 psi

      Elongation at break 1.3%

      Modulus of Elasticity 1020 ksi

      Flexural Modulus 754 ksi

      Flexural Yield Strength 27600 psi

      Compressive Yield Strength 21800 psi

      Glass content, average 35%

      Vertical wall panels will not deform more than L/200 when loaded with 80 lbs/cu ft. soil

      mass. Similar performance with heavier media is available per specification.

      D. Finish: specified finish; factory finished.

      E. Sizes: Modular units fabricated to size by manufacturer as required to fill specified

      areas. Refer to catalog for standard sizes. Custom sizes as per approved shop drawings.

      F. Fire retardant requirement can be met with the addition of retardant chemicals to the

      resin. Additional information is available for this specification.

      2.3 PLANTER ACCESSORIES

      A. Field installed drainage/irrigation connection fitting. Thread-by-thread thermoplastic

      drainage adapter, ½”, ¾” and 1"NPT female thread available. Contractor to locate drainage

      hole, drill as necessary, and install fitting.

      B. Lifting hooks or stabilizer anchors, quantity, size, and capacity as specified.

      3.0 EXECUTION

      3.1 PREPARATION

      A. Prior to planter or planter liner fabrication, the contractor shall verify as-built dimensions

      of planter area or receptacles to ensure proper size, fit and quantity required.1

      B. Unless planters have drainage fittings as in 2.3.A, drainage holes to be located and made

      by contractor in the field to fit to drainage system.

      3.2 INSTALLATION

      A. Install planter liners to allow for easy removal if necessary.

      B. Provide continuous basal support.

      C. Install liners level to permit adequate drainage and irrigation.

      1 Field verification of actual planter receptacle size is frequently overlooked by the contractor, and can

      lead to delays and additional cost if neglected.

    Specifiche tecniche
    • Rif. Unicobioretention-planters-gfrc
    • Famiglia di prodottoBioretention Planters
    • Gruppo di famigliaBioretention GFRC
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2024-06-04
    • Numero di versione1
    Relativo a
    • Materiale principaleCalcestruzzo
    • Progettato inStati Uniti
    • Prodotto inStati Uniti
    Classificazioni
    • Categoria BIMobjectPaesaggio ed esterni - Paesaggio - Altro

    Disponibilità Regionale

    Europa Nord America Asia Sud America
    Albania
    Anguilla
    Armenia
    Argentina
    Andorra
    Antigua e Barbuda
    Azerbaijan
    Bolivia
    Austria
    Aruba
    Bangladesh
    Brasile
    Belgio
    Bahamas
    Bhutan
    Cile
    Bielorussia
    Barbados
    Brunei
    Colombia
    Bosnia ed Erzegovina
    Belize
    Cambogia
    Ecuador
    Bulgaria
    Bermuda
    Cina
    Guiana Francese
    Cipro
    Canada
    Corea del Nord
    Guyana
    Città del Vaticano
    Costa Rica
    Corea del Sud
    Isole Falkland (Malvine)
    Croazia
    Cuba
    Filippine
    Paraguay
    Danimarca
    Curaçao
    Georgia
    Perù
    Estonia
    Dominica
    Giappone
    Suriname
    Finlandia
    El Salvador
    Hong Kong
    Uruguay
    Francia
    Giamaica
    India
    Venezuela
    Germania
    Grenada
    Indonesia
    Gibilterra
    Groenlandia
    Isola di Natale
    Grecia
    Guadalupa
    Isole Cocos (Keeling)
    Guernsey
    Guatemala
    Kazakistan
    Irlanda
    Haiti
    Kirghizistan
    Islanda
    Honduras
    Laos
    Isola di Man
    Isole BES
    Macau
    Isole Åland
    Isole Cayman
    Maldive
    Isole Faroe
    Isole Turks e Caicos
    Malesia
    Italia
    Isole Vergini Americane
    Mongolia
    Jersey
    Isole Vergini britanniche
    Myanmar (Burma)
    Lettonia
    Martinica
    Nepal
    Liechtenstein
    Messico
    Pakistan
    Lituania
    Montserrat
    Singapore
    Lussemburgo
    Nicaragua
    Sri Lanka
    Macedonia del Nord
    Panamá
    Tagikistan
    Malta
    Porto Rico
    Tailandia
    Moldavia
    Repubblica Dominicana
    Taiwan
    Monaco
    Saint Kitts e Nevis
    Territori Britannici dell'Oceano Indiano
    Montenegro
    Saint Martin
    Turkmenistan
    Norvegia
    Saint Vincent e Grenadine
    Uzbekistan
    Paesi Bassi
    Saint-Barthélemy
    Vietnam
    Polonia
    Saint-Pierre e Miquelon
    Portogallo
    Santa Lucia
    Regno Unito
    Sint Maarten
    Repubblica Ceca
    Stati Uniti
    Romania
    Trinidad e Tobago
    Russia
    San Marino
    Serbia
    Slovacchia
    Slovenia
    Spagna
    Svalbard e Jan Mayen
    Svezia
    Svizzera
    Ucraina
    Ungheria