    COLLECTanDRAIN Model 5450 Self-Maintaining Auxiliary Drain

    The COLLECTanDRAIN® Model 5450 Series of auxiliary drains feature a traditionally configured condensation collection assembly contained inside an insulated and heated cabinet. By incorporating a unique, self-maintaining design the Model 5450 offers more than just freeze protection. This feature prevents the auxiliary drain from filling beyond the safety level of the heated cabinet and automatically sheds condensation from the collection assembly when the level reaches approximately 80%. Any additional accumulation will flow into a drain trap that allows the excess to automatically drain from the system while maintaining the integrity of the dry valve. The easily mounted, lockable, steel cabinet is finished in a highly-visible, red, powder coat that includes appropriate identification signage and can be wired to the fire panel for remote notification. The Model 5450 is designed for installation in climates where freezing or below freezing temperatures are present and result in the failure of typical collectors. The Model 5450 maintains a comfortable temperature above freezing while minimizing power consumption. Available with galvanized or black steel and an optional Hot Operation Trouble (HOT) Monitor.

    Model 5450A has galvanized piping and model 5450B includes black steel piping.

    Model 5450H includes the hot operation trouble (HOT) monitor to send notifications if there is a heater issue. The Hot Operation Trouble (HOT) monitor tracks the heater's on/off cycles and compares that information against its own internal thermostat to make sure the heater is performing correctly. For example, if the cabinet door is accidentally left open causing the heater to run continuously, the HOT monitor will trip the local audible and visual alarms and alert the fire control panel. It will also trigger a notification if it detects that the heater is not operating enough to keep the interior temperature safely above freezing.

    Voce di capitolato
    • Model 5450 COLLECTANDRAIN

      2.1 DRY-PIPE SYSTEM AUXILIARY DRAIN

      Auxiliary Drain and Condensation Collecting Assemblies for Dry Pipe and Preaction Sprinkler Systems shall be installed in order to provide for complete system drainage. Where the trapped capacity of an isolated section of system piping exceeds 5 gallons an auxiliary drain shall be provided. The auxiliary drain shall be installed in an accessible location and be capable of collecting and removing moisture from the system while minimizing the potential for excessive loss of air pressure and possible unplanned operation of the dry pipe valve. The Auxiliary Drains shall meet the following requirements:

      1. Manufacturers: Subject to compliance with requirements, available manufacturers offering products that may be incorporated into the work include, but are not limited to, the following:
        1. AGF Manufacturing Inc.; Model 5450 COLLECTANDRAIN™.
        2. <Insert manufacturer's name>.
      2. Standards:
        1. NFPA 13.
        2. NFPA 25.
      3. Components:
        1. Cabinet: A secure locking, red powder-coated, insulated cabinet with required signage adhering to NFPA guidelines.
        2. Heating Element: Temperature-sensitive internal heating element to prevent excess condensation in the drum drip from freezing.
        3. Float Switch: Activates an audible alarm and visual signal to notify when the auxiliary drain requires maintenance.
        4. System Alarm Test Button: An integral TEST button allows for system testing.
        5. Thermometer: Externally mounted for easy monitoring of temperature conditions inside the cabinet.
        6. Drain Assembly:
          1. Two 1 inch by 2 inches (25 mm by 51 mm) Bell Reducers.
          2. 2 inch by 12 inches long (51 mm by 305 mm) Condensate Nipple.
          3. 1 inch (25 mm) Galvanized Square Head Plug.
          4. Two 1 inch (25 mm) MIPT x FIPT Brass quarter-turn ball valves with chrome-plated balls.
          5. Ancillary drain with Y strainer to shed accumulated water when the auxiliary drain reaches approximately 80% full.
          6. Mounting hardware.
          7. Each unit is fully assembled and ready to be attached to dry pipe systems using galvanized or black piping components and 1-inch brass quarter-turn ball valves with chrome-plated brass balls.
    • 4. Product: Model 5450A. Cabinet with Galvanized Auxiliary Drain, Heater, and Ancillary Drain.
    • 5. Product: Model 5450B. Cabinet with Black Steel Pipe Auxiliary Drain, Heater, and Ancillary Drain.
    • 6. Product: Model 5450H. Cabinet with Galvanized Auxiliary Drain, Heater, Ancillary Drain, and Hot Operation Trouble Monitor.
    • 7. Product: Model 5680A. All-Weather Cover for Exposed Locations.
    Specifiche tecniche
    • Rif. Unicoagf-model-5450
    • Famiglia di prodottoAGF Fire Sprinkler Products
    • Gruppo di famigliaCOLLECTanDRAIN
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2022-03-03
    • Numero di versione1
    • Altezza (pollici)36
    • Larghezza (pollici)18
    • Profondità (pollici)12
    Relativo a
    • Materiale principaleAcciaio zincato
    • Materiale secondarioAcciaio verniciato a polvere
    • Progettato inStati Uniti
    • Prodotto inStati Uniti
    • Peso Netto (Libbre)66
    Classificazioni
    • Categoria BIMobjectProdotti antincendio - Impianti sprinkler
    • Clasificazione IFCValvola
    • Codice ETIMEG000056
    • Nome ETIMFire protection systems
    • Nome UNSPSCFire sprinkler systems
    • Codice UNSPSC46191602
    • Codice CSI MasterFormat 201421 00 00
    • Titolo CSI MasterFormat 2014Fire Suppression
    • Numero OmniClass23-29 33 00
    • Titolo OmniClassFire Suppression System Components
    • Codice CSI UniFormat IID40
    • Titolo CSI UniFormat IIFIRE PROTECTION

    Disponibilità Regionale

    Asia Europa Africa Sud America Oceania Nord America
    Afghanistan
    Albania
    Algeria
    Argentina
    Australia
    Bahamas
    Arabia Saudita
    Austria
    Angola
    Bolivia
    Figi
    Belize
    Armenia
    Belgio
    Benin
    Brasile
    Isole Salomone
    Canada
    Azerbaijan
    Bielorussia
    Botswana
    Cile
    Nuova Caledonia
    Costa Rica
    Bangladesh
    Bosnia ed Erzegovina
    Burkina Faso
    Colombia
    Nuova Zelanda
    Cuba
    Bhutan
    Bulgaria
    Burundi
    Ecuador
    Papua Nuova Guinea
    El Salvador
    Cambogia
    Cipro
    Camerun
    Guiana Francese
    Timor Est
    Giamaica
    Cina
    Croazia
    Ciad
    Guyana
    Vanuatu
    Groenlandia
    Corea del Nord
    Danimarca
    Congo
    Isole Falkland (Malvine)
    Guatemala
    Corea del Sud
    Estonia
    Costa d'Avorio
    Paraguay
    Haiti
    Emirati Arabi Uniti
    Finlandia
    Egitto
    Perù
    Honduras
    Filippine
    Francia
    Eritrea
    Suriname
    Messico
    Georgia
    Germania
    eSwatini
    Uruguay
    Nicaragua
    Giappone
    Grecia
    Etiopia
    Venezuela
    Panamá
    Giordania
    Irlanda
    Gabon
    Porto Rico
    India
    Islanda
    Gambia
    Repubblica Dominicana
    Indonesia
    Italia
    Ghana
    Stati Uniti
    Iran
    Lettonia
    Gibuti
    Iraq
    Lituania
    Guinea
    Israele
    Lussemburgo
    Guinea Equatoriale
    Kazakistan
    Macedonia del Nord
    Guinea-Bissau
    Kirghizistan
    Moldavia
    Kenya
    Kuwait
    Montenegro
    Lesotho
    Laos
    Norvegia
    Liberia
    Libano
    Paesi Bassi
    Libia
    Malesia
    Polonia
    Madagascar
    Mongolia
    Portogallo
    Malawi
    Myanmar (Burma)
    Regno Unito
    Mali
    Nepal
    Repubblica Ceca
    Marocco
    Oman
    Romania
    Mauritania
    Pakistan
    Russia
    Mozambico
    Palestina
    Serbia
    Namibia
    Qatar
    Slovacchia
    Niger
    Siria
    Slovenia
    Nigeria
    Sri Lanka
    Spagna
    Repubblica Centrafricana
    Tagikistan
    Svalbard e Jan Mayen
    Repubblica Democratica del Congo
    Tailandia
    Svezia
    Ruanda
    Taiwan
    Svizzera
    Sahara Occidentale
    Turchia
    Ucraina
    Senegal
    Turkmenistan
    Ungheria
    Sierra Leone
    Uzbekistan
    Somalia
    Vietnam
    Sudafrica
    Yemen
    Sudan
    Sudan del Sud
    Tanzania
    Togo
    Tunisia
    Uganda
    Zambia
    Zimbabwe