Pubblica i tuoi prodotti
PC-300 - Energy Monitoring Power Conditioner & Controller 300
PC-300 - Energy Monitoring Power Conditioner & Controller 300
PC-300 - Energy Monitoring Power Conditioner & Controller 300

    PC-300 - Energy Monitoring Power Conditioner & Controller 300

    The PC-300 is a professional grade, rack-mountable power conditioner and controller designed to provide 120 Volt AC power distribution, switching, surge protection, noise filtering, and energy monitoring for Crestron® control systems, AV systems, computers, and other equipment. Eight individually-switched outlets are provided on the rear panel, plus a single unswitched convenience outlet is provided on the front. All nine outlets are protected, filtered, and monitored. The switched outlets are each turn-on delay-adjustable when controlled from the front panel power switch. The switched outlets are also individually controllable via a control system to enable independent switching of devices, on/off power sequencing, load-shedding, and other custom power control functionality.[1]

    Built-in RMS voltage and current monitoring enables logging and reporting of line voltage fluctuations at the input, as well as current, power, and energy usage at each outlet. An external temperature sensor is included to keep tabs on heat conditions within the equipment rack or room. Network connectivity allows for setup and operation using a web browser, with extensive custom control and monitoring capabilities enabled through integration with a Crestron control system, the MyCrestron.com residential monitoring service, the Crestron Fusion® Cloud enterprise management service, or an SNMP client.[1,2] Setup and operation can also be performed through the LCD front panel.

    Power Conditioning
    A quality power conditioner is an essential component of any professional system to prevent sudden equipment failure due to lightning and electrical disturbances, to prolong the lifespan of that equipment, and to maximize overall system performance during everyday operation. The PC-300 includes the following power conditioning features:
    • Surge Protection — Provides protection against surges and spikes in the AC power line caused by lightning and other electrical disturbances
    • Under/Over Voltage Cutoff — Shuts off power to the rear panel outlets if the line voltage strays beyond the normal operating range, which is adjustable on the PC-300
    • Thermal Breaker — Disrupts power to all outlets in case of an overload condition
    • EMI/RFI Noise Filtering — Prevents electromagnetic and radio frequency interference that can negatively impact sound and video quality
    • Wiring Fault Detection — Detects faulty wiring of the incoming AC power line and shuts off power to the rear panel outlets until the fault is corrected [3]

    Eight-Stage Adjustable Turn-On Delay
    When operated by its front panel power switch, the PC-300 allows each of its rear panel outlets to turn on in any order according to the delay time set for each outlet. Each outlet is individually adjustable to provide up to 10 seconds of delay before turning on, ensuring that the connected equipment gets powered up in proper order with sufficient time for each piece to stabilize. This helps to prevent dangerous transients that can damage delicate components and potentially trip the main circuit breaker. It can also help to prevent audible pops and thumps through connected audio equipment at power-up. Delayed turn-on is initiated by turning on the front panel power switch, or by applying power to the main line input following a power outage or through an externally switched circuit.

    Eight Remote-Controllable Switched Outlets
    Any of the PC-300’s eight rear panel outlets can be turned on or off individually through the front panel LCD screen or over the network using a web browser or control system. This energy-saving feature allows select components to be powered down when not needed. Through integration with a control system, custom functionality can be programmed to enable control from a touch screen, keypad, remote, or mobile device. Sequential power-up and power-down functionality can be enabled through programming of the control system, with select outlets designated as always on. For systems employing a backup generator or UPS, load-shedding can be performed to shut down unnecessary components during a power outage.[1]

    Energy Monitoring
    By sensing the incoming line voltage and individual device loads, the PC-300 facilitates a host of solutions for monitoring, automating, and troubleshooting a system.
    • Voltage monitoring allows fluctuations in the power line to be tracked and logged, helping to identify and document problems with the power utility or building wiring.
    • Energy monitoring per outlet provides the real power consumption (watts), current draw (amps), and energy usage (watt-hours) for each connected device.
    • Allows power-hungry equipment to be identified and replaced with more efficient equipment.
    • High inrush current devices can be identified to assist in optimizing the configuration of power sequencing schemes.
    • Overall energy usage can be tracked and logged to identify trends and reform energy-wasting behaviors.
    • Individual device usage can be tracked to inform the scheduling of maintenance and future purchasing decisions.
    • The power state of an IR controlled device can often be determined by sensing its AC current draw, ensuring it’s on when it should be on.
    • An alert notification can be sent if there’s a sudden or abnormal drop in current draw, potentially indicating a device has been shut off improperly or disconnected due to theft (effective only when outlets are switched on).

    Ambient Temperature Sensing
    The PC-300 offers a complete equipment protection solution by monitoring the ambient temperature within the equipment cabinet or room to prevent overheating. The included temperature sensor connects to the rear of the PC-300 and features a choice of magnetic or adhesive mounting for easy placement within a typical equipment rack enclosure. The over-temperature cutoff threshold can be set to shut down power to the system if conditions exceed a safe operating temperature. Through a control system, the temperature measurement can be utilized to regulate the operation of cooling fans or air-conditioning equipment to keep equipment running cool.

    Ping Monitoring
    No matter how well a system is designed and programmed, even the finest control system or computer has the potential to lock up and stop responding once in a while. The PC-300 can be configured to detect an unresponsive device by sending it a ping command at regular intervals. If the ping request is not returned after four tries, the outlet feeding the monitored device cycles off and on to reboot the device, quickly restoring normal operation without any human intervention.

    Built-In Logging
    Events such as power surges, over/under voltage conditions, over-temperature conditions, ping failures, outlet switching activity, and sudden changes in current draw (indicative of a device being improperly shut off or disconnected) can all be logged as they occur to document the time and cause of problems and to track device usage. All sensor readings are logged at a configurable interval as short as five seconds providing a minimum of one week’s worth of data. Logs can be retrieved periodically to record a detailed history of events and energy usage over time.

    UL® 1449 Certified
    The PC-300 has been tested and certified by UL as compliant with the UL 1449 safety and performance standard for surge protective devices (SPD).
      
    Key Features
    • Rack-mountable power conditioner and controller
    • Eight individual-switched rear panel outlets
    • Adjustable turn-on delay and local/remote switching per outlet
    • One unswitched front panel outlet
    • Built-in current sensing and energy monitoring per outlet
    • Line voltage monitoring
    • Professional grade surge protection
    • UL® 1449 Type 3 Listed
    • Thermal breaker overload protection
    • Adjustable over-voltage and under-voltage cutoff
    • EMI and RFI noise filtering
    • Wiring fault detection [3]
    • Ambient temperature sensing and over-temperature cutoff
    • Ping monitoring (device lockup detection and reboot)
    • Built-in energy usage and event logging
    • Front panel main power switch, status indicators, and color LCD
    • Easy setup and operation via front panel or web browser
    • Crestron® control system integration via Ethernet or Cresnet®
    • Remote management via MyCrestron.com, Crestron Fusion® Cloud, or SNMP [2]
    • Single-space 19 inch rack-mountable
    • Rated 15 Amps at 120 Volts AC
    • Limited Lifetime Product Warranty
    • Limited 5 Year Connected Equipment Protection Warranty

    1. Crestron control system and custom programming sold separately.
    2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.
    3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-300 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-300 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation.

    Voce di capitolato
    • Power Conditioner & Controller

      Maximum Output Current, Total - 15 Amps @ 120 Volts AC
      Maximum Output Current, Per Outlet - 15 Amps @ 120 Volts AC (subject to a maximum total output current of 15 Amps for all outlets combined)
      Filtration - 40 dB @ 100 kHz, 50 dB @ 300 kHz, with 50 Ohm load
      Surge Protection Modes - L-G, L-N, N-G
      Surge Protection Shutoff - Shuts off rear outlets if surge protection is compromised
      Energy Dissipation - 2000 Joules per Mode
      Clamping Voltage - 370 Volts
      Clamping Time - 1 ns
      Wiring Fault Detection - Shuts off rear outlets if a wiring fault is detected at the input [3]
      Voltage Sensing Range - 90.0 to 160.0 Volts rms ±1%, measured at input
      Current Sensing Range - 0.4 to 15.0 Amps rms ±1% (resistive), measured per outlet
      Ambient Temperature Sensing Range - -13.0° to 221.0° ±4° F (-25.0° to 105.0° ±2° C)
      Under Voltage Cutoff - Adjustable 90 to 110 Volts, shuts off rear outlets if input drops below set value
      Over Voltage Cutoff - Adjustable 130 to 147 Volts, shuts off rear outlets if input exceeds set value
      Over Temperature Cutoff - Adjustable -13.0° to 221.0° F (-25.0° to 105.0° C), shuts off rear outlets if input exceeds set value
      Turn-On Delay Adjustment - 0.1 to 10.0 seconds, adjustable per each rear outlet

      Power
      Line Power - 15 Amps @ 120 Volts AC, 60 Hz
      Cresnet Power Usage - 0 Watts

      Communications
      Ethernet - 10/100 Mbps, auto-switching, auto-negotiating, auto-discovery, full/half duplex, TCP/IP, UDP/IP, CIP, DHCP, SSL, TLS, SNMP, Web Server, SMTP e-mail client, web browser setup and control, Crestron control system integration, Crestron Fusion Cloud monitoring, MyCrestron.com monitoring [2]
      Cresnet - Cresnet slave mode

      Connectors
      120V~ 15A 60Hz - (1) Attached 9.8 ft (3 m) grounded AC power cord with NEMA 5-15P plug; Line power input
      OUTLET 1 – 8 - (8) NEMA 5-15R AC power outlets; Individually-switched 120 Volt AC power outlets; Locally switched (via power switch) with adjustable turn-on delay per outlet; Local (via LCD) or remote switchable per outlet
      TEMP - (1) 2-pin 3.5 mm detachable terminal block; Connection for external temperature sensor (included)
      Y, Z, G - (1) 3-pin 3.5 mm detachable terminal block; Cresnet slave port
      LAN - (1) 8-pin RJ45 jack; 10Base-T/100Base-TX Ethernet port
      G - (1) 6-32 screw; Chassis ground lug
      ALWAYS ON (front) - (1) NEMA 5-15R AC power outlet; Unswitched 120 Volt AC power outlet

      Controls & Indicators
      PWR - (1) Bi-color green/amber LED, indicates line power is present, illuminates amber when the power switch is off and while booting, illuminates green when the power switch is on and the unit is operating normally, turns amber if the rear outlets have been shut off due to a fault condition
      FAULT - (1) Red LED, indicates any of the following fault conditions: surge protection is compromised, line and neutral are reversed, or no ground is detected [3]
      PROTECT - (1) Green LED, indicates surge protection is fully functional
      SHUTDOWN - (1) Amber LED, indicates power to the rear outlets is shut off due to an over-voltage, under-voltage, over-temperature, line input miswire, missing ground, or compromised surge protection fault condition
      HW-R - (1) Recessed pushbutton, initiates a hardware reset of the internal CPU (does not affect outlets)
      Display - (1) 2 inch (52 mm) diagonal, 220 x 176 pixels, 16-bit TFT active matrix color LCD, displays configuration and status menus
      Nav Pad - (1) 5-way navigation pad for menu navigation and adjustment of settings
      HOME - (1) Pushbutton, opens or returns to the home menu
      BACK - (1) Pushbutton, steps menu back one level
      Power Switch - (1) Rocker switch, "On" position initiates turn-on delay sequence to the rear panel outlets, "Off" position turns all rear outlets off immediately
      THERMAL BREAKER (rear) - Disrupts power to all outlets in case of an overload condition, press to reset after overload condition is resolved
      LAN (rear) - (2) LEDs, green LED indicates Ethernet link status, amber LED indicates Ethernet activity

      Environmental
      Temperature - 32° to 113° F (0° to 45° C)
      Humidity - 10% to 90% RH (non-condensing)

      Construction
      Chassis - Steel, black finish
      Front Panel - Extruded aluminum, black finish, polycarbonate label overlay
      Mounting - 1 RU 19-inch rack-mountable (rack ears included)
      Temperature Sensor - Adhesive or magnetic mount, 9.8 ft (3.0 m) attached lead

      Dimensions
      Height - 1.73 in (44 mm)
      Width - 17.32 in (440 mm); 19.00 in (483 mm) with rack ears
      Depth - 10.56 in (269 mm)
      Weight - 8.2 lb (3.8 kg)

      Compliance
      UL 1449 Type 3 Listed

      1. Crestron control system and custom programming sold separately.
      2. Email notification and direct integration with MyCrestron.com, Crestron Fusion, and SNMP will be enabled through a future firmware update. Alternately, these services can be integrated now through a Crestron control system with custom programming.
      3. Detects most input line wiring faults. Does not detect neutral/ground reversal. Does not discern between ground connections at the AC power line, chassis, or connected equipment (a ground connection at any point will be detected by the PC-300 as normal). The installer is responsible for proper wiring and grounding of this and all connected equipment according to applicable electrical codes, accepted guidelines, and best practices. Proper wiring and function of the AC power source should be verified prior to connecting the PC-300 or any other equipment. Use of this product does not negate the responsibilities of the installer and end-user to exercise all appropriate and required measures for safe and reliable installation and operation

    Specifiche tecniche
    • Rif. Unicocrestron-PC-300
    • Famiglia di prodottoAccessories
    • Gruppo di famigliaPower Supplies
    • TipoOggetto (oggetto singolo)
    • Data di pubblicazione2018-04-30
    • Numero di versione1
    • Altezza (pollici)1.73
    • Profondità (pollici)10.56
    Relativo a
    • Progettato inStati Uniti
    • Prodotto inStati Uniti
    • Peso Netto (Libbre)3.8
    Classificazioni
    • Categoria BIMobjectElementi elettronici - Controls
    • Clasificazione IFCApparecchiatura elettrica
    • Codice ETIMEC000678
    • Nome ETIMRemote control
    • Nome UNSPSCElectrical controls and accessories
    • Codice UNSPSC391215
    • Codice Uniclass 2015Pr_40_30_86_88
    • Descrizione Uniclass 2015Touch panels
    • Codice CSI MasterFormat 201440 67 23
    • Titolo CSI MasterFormat 2014Control System Consoles
    • Numero OmniClass23-27 13 13 11
    • Titolo OmniClassBuilding Automated Control Panels

    Disponibilità Regionale

    Europa Asia Nord America Africa Sud America Oceania
    Albania
    Afghanistan
    Anguilla
    Algeria
    Argentina
    Australia
    Andorra
    Arabia Saudita
    Antigua e Barbuda
    Angola
    Bolivia
    Figi
    Austria
    Armenia
    Aruba
    Benin
    Brasile
    Guam
    Belgio
    Azerbaijan
    Bahamas
    Botswana
    Cile
    Isola Norfolk
    Bielorussia
    Bahrein
    Barbados
    Burkina Faso
    Colombia
    Isole Cook
    Bosnia ed Erzegovina
    Bangladesh
    Belize
    Burundi
    Ecuador
    Isole Marianne Settentrionali
    Bulgaria
    Bhutan
    Bermuda
    Camerun
    Guiana Francese
    Isole Marshall
    Cipro
    Brunei
    Canada
    Capo Verde
    Guyana
    Isole Minori Esterne degli Stati Uniti
    Città del Vaticano
    Cambogia
    Costa Rica
    Ciad
    Isole Falkland (Malvine)
    Isole Pitcairn
    Croazia
    Cina
    Cuba
    Comore
    Paraguay
    Isole Salomone
    Danimarca
    Corea del Nord
    Curaçao
    Congo
    Perù
    Kiribati
    Estonia
    Corea del Sud
    Dominica
    Costa d'Avorio
    Suriname
    Nauru
    Finlandia
    Emirati Arabi Uniti
    El Salvador
    Egitto
    Uruguay
    Niue
    Francia
    Filippine
    Giamaica
    Eritrea
    Venezuela
    Nuova Caledonia
    Germania
    Georgia
    Grenada
    eSwatini
    Nuova Zelanda
    Gibilterra
    Giappone
    Groenlandia
    Etiopia
    Palau
    Grecia
    Giordania
    Guadalupa
    Gabon
    Papua Nuova Guinea
    Guernsey
    Hong Kong
    Guatemala
    Gambia
    Polinesia Francese
    Irlanda
    India
    Haiti
    Ghana
    Samoa
    Islanda
    Indonesia
    Honduras
    Gibuti
    Samoa Americane
    Isola di Man
    Iran
    Isole BES
    Guinea
    Stati Federati di Micronesia
    Isole Åland
    Iraq
    Isole Cayman
    Guinea Equatoriale
    Timor Est
    Isole Faroe
    Isola di Natale
    Isole Turks e Caicos
    Guinea-Bissau
    Tokelau
    Italia
    Isole Cocos (Keeling)
    Isole Vergini Americane
    Kenya
    Tonga
    Jersey
    Israele
    Isole Vergini britanniche
    Lesotho
    Tuvalu
    Lettonia
    Kazakistan
    Martinica
    Liberia
    Vanuatu
    Liechtenstein
    Kirghizistan
    Messico
    Libia
    Wallis e Futuna
    Lituania
    Kuwait
    Montserrat
    Madagascar
    Lussemburgo
    Laos
    Nicaragua
    Malawi
    Macedonia del Nord
    Libano
    Panamá
    Mali
    Malta
    Macau
    Porto Rico
    Marocco
    Moldavia
    Maldive
    Repubblica Dominicana
    Mauritania
    Monaco
    Malesia
    Saint Kitts e Nevis
    Mauritius
    Montenegro
    Mongolia
    Saint Martin
    Mayotte
    Norvegia
    Myanmar (Burma)
    Saint Vincent e Grenadine
    Mozambico
    Paesi Bassi
    Nepal
    Saint-Barthélemy
    Namibia
    Polonia
    Oman
    Saint-Pierre e Miquelon
    Niger
    Portogallo
    Pakistan
    Santa Lucia
    Nigeria
    Regno Unito
    Palestina
    Sint Maarten
    Repubblica Centrafricana
    Repubblica Ceca
    Qatar
    Stati Uniti
    Repubblica Democratica del Congo
    Romania
    Singapore
    Trinidad e Tobago
    Riunione
    Russia
    Siria
    Ruanda
    San Marino
    Sri Lanka
    Sahara Occidentale
    Serbia
    Tagikistan
    Sant'Elena
    Slovacchia
    Tailandia
    São Tomé e Príncipe
    Slovenia
    Taiwan
    Senegal
    Spagna
    Territori Britannici dell'Oceano Indiano
    Seychelles
    Svalbard e Jan Mayen
    Turchia
    Sierra Leone
    Svezia
    Turkmenistan
    Somalia
    Svizzera
    Uzbekistan
    Sudafrica
    Ucraina
    Vietnam
    Sudan
    Ungheria
    Yemen
    Sudan del Sud
    Tanzania
    Togo
    Tunisia
    Uganda
    Zambia
    Zimbabwe