Termékek közzététele
Single Stage Infrared Heater, Model UXR

Single Stage Infrared Heater, Model UXR

Includes all of the features in a Model UX plus... the burner box is sealed for rugged, harsh environments and heat-treated aluminized is standard tube supplied. CSA approved for outdoor use.

  • Approved for outdoor use
  • 40,000 to 220,000 btu/h
  • Natural gas and LPG
  • Configurations of "U" and "L", horizontal or 45°
  • Separated controls compartment – electronics out of air stream, burner can run during servicing
  • Self diagnostic ignition module
  • Parabolic aluminum reflectors – most efficient in industry
  • Direct spark ignition
  • Vented or unvented
  • Operating status light
  • Low voltage controls
  • Jet stream burner – improved heat distribution, better combustion
  • Heavy duty couplings – no leaks, cannot be over tightened
  • UXR features burner box sealed for outdoor conditions
  • Rubber gaskets
  • Silicone used to seal corners and joints
  • Weather resistant electrical components used for exterior connections
  • Stainless steel burner boxes available as well as tubing and reflectors
  • Units are wind resistant
  • Three year warranty on all components
  • Seven year warranty on aluminized heat exchanger
  • 10 year warranty on aluminized heat exchanger with post purge feature


Specifikáció
  • Low-Intensity Single Stage Infrared Tube Heaters with minimum 65% radiant factor as determined by independent lab testing to EN416-2 Standard. Baffles required as per manufacturer’s instructions. 

    Assemblies shall be CSA approved low-intensity heater to the latest ANSI Z83.20 and CSA 2.34 for use in commercial and industrial applications. Burner shall be a positive pressure burner system, where exhaust gases and other products of combustion are not routed through the blower. The burner shall operate at a minimum gas inlet pressure of 5.0 inches W.C. (natural gas) or 11.5 inches W.C. (propane) and draw no more than 1 Amp at 120VAC, 60Hz.
    Burner head shall be chrome-plated steel and burner controls shall be located outside of the air supply stream to allow service and diagnostic control checks with the burner operating. Reflector shall be a 10-sided reflector design reflecting virtually 100% of the infrared energy out and away from the emitter tubes. Reflector shall be “Deep Dish” design with emitter tubes fully recessed within the reflector. Reflectors with less than 10 surfaces will not be allowed. Reflector shall be mill-finished aluminum, ASTM 1100, .024 inch thick aluminum sheet metal with two reflector support brackets for every 10 feet (3048 mm) reflector section. Reflectors shall extend below the lowest position of the tubing at all times. Reflector end caps shall be fitted to the end of each reflector run to reduce convective heat loss and shall be standard equipment. Emitter Tube shall be 4 inches (102 mm) diameter, minimum 16 gauge thickness. Combustion Tube shall be 4 inches (102 mm) diameter, 16 gauge, heat-treated type 1 aluminized steel tubing shall be required for all firing rates.  Hot rolled steel combustion tubing shall not be allowed. Combustion tubing shall incorporate a welded, 11 gauge steel, 4 bolt flange to orient the burner to the tube as designed. Couplings shall be 16 gauge aluminized steel, minimum 12 inches in length, and be of heavy-duty design incorporating two 1-inch wide draw bands.

    This product was specified based on best practice design to meet the specific engineered design criteria for this project. 

    Any submission for substitution must include the following material for consideration or bid will be deemed unqualified and rejected:

    • Independent lab testing to EN416-2 standard dated no later than 6 months from date of submission showing a minimum 65% radiant factor
    • Professional Engineer Stamped Design, calculations, and complete set of stamped drawings with alternate systems.
    • Stamped fuel usage data showing a minimum 20% fuel savings over specified Superior Radiant Model 
    • Verification that Manufacturer successfully completed and passed the auditing requirements for ISO 9001 Quality Management System (QMS).
Műszaki specifikáció
  • Egyedi azonosítóuxr
  • TermékcsaládSingle Stage Infrared Heaters
  • TermékcsoportLow Intensity - Series U
  • TípusObjektum (egy termék)
  • Megjelenés dátuma2021-02-16
  • Verziószám1
Kapcsolódó adatok
  • Elsődleges anyagAcél
  • Másodlagos anyagAlumínium
  • Tervezés helyeKanada
  • Gyártás helyeKanada
Besorolások
  • BIMobject kategóriaHVAC - Fűtőtestek
  • UNSPSC névTubular heaters
  • UNSPSC kód40101822
  • Uniclass 2015 kódPr_70_60_36_72
  • Uniclass 2015 leírásRadiant tube heaters
  • CSI MasterFormat 2014 kód23 55 23
  • CSI MasterFormat 2014 névGas-Fired Radiant Heaters
  • OmniClass szám23-33 15 17 13
  • OmniClass névFuel Fired HVAC Radiant Heaters
  • CSI UniFormat II kódD30
  • CSI Uniformat II névHVAC

Termék elérhetősége

Észak-Amerika
Anguilla
Antigua és Barbuda
Aruba
Bahama-szigetek
Barbados
Belize
Bermuda
Brit Virgin-szigetek
Caribbean Netherlands
Costa Rica
Curaçao
Dominikai Közösség
Dominikai Köztársaság
Egyesült Államok
El Salvador
Grenada
Grönland
Guadeloupe
Guatemala
Haiti
Honduras
Jamaica
Kajmán-szigetek
Kanada
Kuba
Martinique
Mexikó
Montserrat
Nicaragua
Panamaváros
Puerto Rico
Saint Kitts és Nevis
Saint Lucia
Saint Pierre és Miquelon
Saint Vincent és a Grenadine-szigetek
Saint-Barthélemy
Saint-Martin
Sint Maarten
Trinidad és Tobago
Turks- és Caicos-szigetek
Virgin-szigetek