Termékek közzététele
CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

The CHV-TSTAT-FCU is a versatile heating and cooling thermostat for fan coil unit (FCU) HVAC systems. Relative humidity capability can be added through an external remote humidity sensor (sold separately). Although functional as a standalone thermostat, the CHV-TSTAT delivers greatly enhanced functionality as part of a complete home automation system from Crestron®. Available in white, black, or almond, the stylish wall mount design is a complement to any décor.

The large backlit LCD display, navigable using four simple pushbuttons, provides easy access to indoor and outdoor temperature and humidity readings, setpoint adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity setpoints with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.

Automation System Integration
Multiple Crestron thermostats may be networked via Cresnet® to any 3-Series® control system, including the DIN-AP3, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.

Its connection to the control system also allows for full control and scheduling of the CHV-TSTAT-FCU from touch screens and computers throughout the home, and supports extensive flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT-FCU will remain operable to control the HVAC system.

Remote Sensors
Optional remote temperature and humidity sensors can be connected to the CHV-TSTAT-FCU for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT-FCU to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low-temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT-FCU accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity sensor and two temperature sensors.

Features
Summary Of Features

Wall-mount thermostat for fan coil unit HVAC systems
Multiple Crestron® thermostats may be networked via Cresnet®
Supports remote humidity sensors and outdoor temperature sensors
Backlit LCD display
Front panel buttons for setup, configuring, and temperature and humidity adjustments[1]
Available in white, black, or almond finishes

Notes:
1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Specifikáció
  • Measurement Range
     
    Indoor Temperature: 0° to 110°F (-18° to 43°C)
    Outdoor Temperature: -40° to 170°F (-40° to 77°C)[1]
    Humidity: 0% to 100% RH[1]

    Temperature Tolerance
    Over Full Range: ±1°F (±0.5°C)
    At Room Temperatures: ±1°F (+0.1/-0.4°C)

    Setpoint Range
    Auto Setpoint: 38° to 99°F (3° to 37°C)
    Heat only Setpoint: 38° to 89°F (3° to 32°C)
    Cool only Setpoint: 59° to 99°F (15° to 37°C), or 38° to 99°F (3° to 37°C) extended cool mode enabled
    Humidity Setpoint:5% to 70% RH[1]

    Relay Rating
    1 Amp at 40 Volts DC or 24 Volts AC (nominal)

    Power Requirements
    24V: 2 Watts (0.083 Amps) at 24 Volts AC, supplied by heating or cooling system
    Cresnet® Power Usage: ‹1 Watts (‹0.05 Amps at 24 Volts DC), required for Cresnet communication only

    Buttons
    MODE: Accesses user controls - system mode, fan mode, humidifier,[1] Crestron® system, and global update
    VIEW: Accesses humidity reading,[1] outdoor temperature reading,[1] system messages, and remote functions
    UP: Selects user modes and increments selection in setup modes
    DOWN: Selects user modes and decrements selection in setup modes

    Display
    Type: Transflective LCD, backlit
    Size: 2.75 in (6.99 cm)
    Resolution: 128 x 64
    Viewing Angle: ±50° horizontal (at 0° vertical), ±50° vertical (at 0° horizontal)
    Displays current indoor temperature and relative humidity,[1] outdoor temperature and relative humidity,[1] setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages

    Connections
    HVAC:
    (2) 9-position terminal blocks comprising the following:

    Power Connections (Required):
    24 (C): 24V AC common terminal supplies remote 24V AC power to thermostat;
    24 (R): 24V AC reference terminal – Can be connected to R by P4 jumper setting, or tied directly to power source

    HVAC Control Connections (System Dependent):
    HUM, RHU: Humidity Control – Energized together during humidity call;
    R, R: Reference – Used for all system calls (except humidity);
    G-L: Fan Low – Energized to R during call for low-speed fan;
    G-M: Fan – Energized to R during call for medium-speed fan;
    G-H: Fan – Energized to R during call for high-speed fan;
    O: Changeover control – Energized to R during cooling modes;
    B: Energized to R during non-cooling modes;
    W: Heat – Energized to R during call for heating;
    Y: Cool – Energized to R during call for cooling

    Remote Sensing Connections (Optional):
    RSR: Remote Sensor Returns – Common sensor terminal;
    RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
    RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
     
    Network
    (1) 4-position terminal block;
    Cresnet slave port, connects to Cresnet control network

    Enclosure
    Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box

    Dimensions
    Height: 3.75 in (96 mm)
    Width: 5.00 in (127 mm)
    Depth: 1.04 in (27 mm)
    Weight: 5.80 oz (165 g)

    Notes:
    1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Műszaki specifikáció
  • Egyedi azonosítócrestron-CHV-TSTAT-FCU
  • TermékcsaládLighting & Environment
  • TermékcsoportClimate Control
  • TípusObjektum (egy termék)
  • Megjelenés dátuma2017-12-10
  • Verziószám1
  • Magasság (hüvelyk)3.75
  • Szélesség (hüvelyk)5
  • Mélység (hüvelyk)1.04
Kapcsolódó adatok
  • Elsődleges anyagMűanyag
  • Tervezés helyeMexikó
  • Gyártás helyeMexikó
  • Nettó tömeg (font)0.3625
Besorolások
  • BIMobject kategóriaElektronika - Controls
  • IFC besorolásElektromos elem
  • CSI MasterFormat 2014 kód40 74 00
  • CSI MasterFormat 2014 névTemperature Measurement
  • OmniClass szám23-27 11 11 15 11
  • OmniClass névDigital Temperature Controllers

Termék elérhetősége

Európa Ázsia Észak-Amerika Afrika Dél-Amerika Óceánia
Åland
Afganisztán
Anguilla
Algéria
Argentína
Amerikai Szamoa
Albania
Azerbajdzsán
Antigua és Barbuda
Angola
Bolívia
Ausztrália
Andorra
Bahrein
Aruba
Benin
Brazília
Cook-szigetek
Ausztria
Banglades
Bahama-szigetek
Bissau-Guinea
Chile
Észak-Mariana-szigetek
Belgium
Bhután
Barbados
Botswana
Ecuador
Fidzsi-szigetek
Bosznia-Hercegovina
Brit Indiai-óceáni Terület
Belize
Burkina Faso
Falkland-szigetek
Francia Polinézia
Bulgária
Brunei Szultanátus
Bermuda
Burundi
Francia Guyana
Guam
Ciprus
Christmas Island
Brit Virgin-szigetek
Comore-szigetek
Guyana
Kelet-Timor
Csehország
Dél-Korea
Caribbean Netherlands
Csád
Kolumbia
Kiribati
Dánia
Egyesült Arab Emírségek
Costa Rica
Dél-afrikai Köztársaság
Paraguay
Marshall-szigetek
Egyesült Királyság
Észak-Korea
Curaçao
Dél-Szudán
Peru
Mikronéziai Szövetségi Államok
Észak-Macedónia
Fülöp-szigetek
Dominikai Közösség
Dzsibuti
Suriname
Nauru
Észtország
Grúzia
Dominikai Köztársaság
Egyenlítői-Guinea
Uruguay
Niue
Fehéroroszország
Hongkong
Egyesült Államok
Egyiptom
Venezuela
Norfolk-sziget
Feröer-szigetek
India
El Salvador
Elefántcsontpart
Palau
Finnország
Indonézia
Grenada
Eritrea
Pápua Új-Guinea
Franciaország
Irak
Grönland
Etiópia
Pitcairn-szigetek
Gibraltár
Irán
Guadeloupe
Gabon
Salamon-szigetek
Görögország
Izrael
Guatemala
Gambia
Szamoa
Guernsey
Japán
Haiti
Ghána
Tokelau
Hollandia
Jemen
Honduras
Guinea
Tonga
Horvátország
Jordánia
Jamaica
Kamerun
Tuvalu
Írország
Kambodzsa
Kajmán-szigetek
Kenya
Új-Kaledónia
Izland
Katar
Kanada
Kongó
Új-Zéland
Jersey
Kazahsztán
Kuba
Kongói Demokratikus Köztársaság
United States Minor Outlying Islands
Lengyelország
Kína
Martinique
Közép-afrikai Köztársaság
Vanuatu
Lettország
Kirgizisztán
Mexikó
Lesotho
Wallis és Futuna
Liechtenstein
Kókusz-szigetek
Montserrat
Libéria
Litvánia
Kuvait
Nicaragua
Líbia
Luxemburg
Laosz
Panamaváros
Madagaszkár
Magyarország
Libanon
Puerto Rico
Malawi
Málta
Makaó
Saint Kitts és Nevis
Mali
Man-sziget
Malajzia
Saint Lucia
Marokkó
Moldova
Maldív-szigetek
Saint Pierre és Miquelon
Mauritánia
Monaco
Mianmar (Burma)
Saint Vincent és a Grenadine-szigetek
Mauritius
Montenegró
Mongólia
Saint-Barthélemy
Mayotte
Németország
Nepál
Saint-Martin
Mozambik
Norvégia
Omán
Sint Maarten
Namíbia
Olaszország
Örményország
Trinidad és Tobago
Niger
Oroszország
Pakisztán
Turks- és Caicos-szigetek
Nigéria
Portugália
Palesztina
Virgin-szigetek
Nyugat-Szahara
Románia
Srí Lanka
Réunion
San Marino
Szaúd-Arábia
Ruanda
Spanyolország
Szingapúr
São Tomé és Príncipe
Svájc
Szíria
Seychelle-szigetek
Svalbard and Jan Mayen
Tádzsikisztán
Sierra Leone
Svédország
Tajvan
Szenegál
Szerbia
Thaiföld
Szent Ilona
Szlovákia
Törökország
Szomália
Szlovénia
Türkmenisztán
Szudán
Ukrajna
Üzbegisztán
Szváziföld
Vatikán
Vietnam
Tanzánia
Togo
Tunézia
Uganda
Zambia
Zimbabwe
Zöld-foki Köztársaság