Commercial 22" Self-flashed Low Profile Sun Tunnel Skylight (TGC) for roof slopes 0 - 60 degrees
Commercial 22" Self-flashed Low Profile Sun Tunnel Skylight (TGC) for roof slopes 0 - 60 degrees
Commercial 22" Self-flashed Low Profile Sun Tunnel Skylight (TGC) for roof slopes 0 - 60 degrees
Commercial 22" Self-flashed Low Profile Sun Tunnel Skylight (TGC) for roof slopes 0 - 60 degrees
Commercial 22" Self-flashed Low Profile Sun Tunnel Skylight (TGC) for roof slopes 0 - 60 degrees

    Commercial 22" Self-flashed Low Profile Sun Tunnel Skylight (TGC) for roof slopes 0 - 60 degrees

    Traduit par Google,

    Le puits de lumière tunnel solaire commercial VELUX avec solin TGC de 22 po est conçu pour fournir une solution d'éclairage naturel rapide et économique pour tout espace où une vue vers l'extérieur n'est pas nécessaire et est destiné aux pentes de toit commerciales de 0 à 60 degrés (20:12) . Les systèmes de puits de lumière tubulaires commerciaux se composent des trois systèmes différents suivants : le système de capture de la lumière sur le toit, le système de transfert de la lumière du tunnel et le système de diffusion. Le solin plat monobloc fournit un solin étanche et homogène qui positionne la zone de captation de la lumière du jour du tunnel perpendiculairement à la surface du toit. Des tourelles de 12" sont disponibles pour les toits plats isolés. Le TGC de 22 pouces est doté d'un grand dôme extérieur en acrylique ou en polycarbonate et d'un VELUX SunCurve pour récolter plus de lumière du jour. Un système 14" est également disponible. Le tunnel rigide miroir hautement réfléchissant transfère efficacement la lumière du jour vers l'espace de travail, et plusieurs options de diffuseur sont disponibles pour répondre aux besoins de l'application : plafond ouvert, plafond suspendu et diffuseurs pour plafond dur. Le système de tunnel pivotant et les coudes réglables facilitent la navigation dans des structures de toit complexes ou de simples parcours droits, ce qui les rend rapides et faciles à installer. Les contrôleurs de lumière du jour et autres accessoires rendent les puits de lumière tubulaires hautement configurables pour répondre à vos besoins. Veuillez visiter notre site Web ou contacter notre équipe de service à la clientèle commerciale au 888-878-3589.

    Les accessoires en option incluent :

    • Contrôleur de lumière du jour et alimentations
    • Kits énergétiques à rupture de pont thermique
    • Améliorateurs de diffusion
    • Bandes de feu en option

    En plus de la taille de 22", il existe une taille de 14" et il existe d'autres systèmes de solin VELUX Sun Tunnel disponibles pour les applications commerciales et résidentielles.

    Spécification
    • PART 2 - PRODUCTS
      2.1 MANUFACTURERS
      A. Basis-of-Design Product: Subject to compliance with requirements, provide products of VELUX America Inc., Greenwood, SC 29648; www.VELUXusa.com; (800) 878-3589, specifications@veluxusa.com. 

      2.2 TUBULAR DAYLIGHTING DEVICES
      A. System Description: Tubular unit skylight daylighting devices with exterior glazed dome, glazing retainers and gaskets, pan flashing assembly with integral adjustable pivot device, reflective tunnel, interior diffuser assemblies, and accessories, as required to meet installation and performance requirements indicated.
      1. Basis of Design: VELUX America, Inc., Model TGC Commercial Pan Flashed Sun Tunnel Skylight.

      2.5 PERFORMANCE REQUIREMENTS
      A. Unit Skylight Standard, 14 inch (356 mm) Unit: AAMA/WDMA/CSA 101/I.S.2/A440 (NAFS-11 or previous): 
      Specifier: Retain first four Subparagraphs below and delete following four Subparagraphs for IBC 2012 and 2015 code requirements; verify requirements of authorities having jurisdiction.
      1. Performance Grade (Primary Designator): TDDCC/TDDOC-PG145.
      2. Design Pressure (DP): +300/-145 psf (+14.4/6.94 kPa).
      3. Water Test Pressure: 15 psf (0.72 kPa) with no leakage at 5 gallons per minute spray rate.
      4. Air Leakage Rate: 0.30 cfm/ft2 maximum.
      Specifier: Delete first four Subparagraphs above and retain first four Subparagraphs below for IBC 2009 and NBC code requirements, including CSA A440S1-09; verify requirements of authorities having jurisdiction.
      5. Performance Class and Grade (Primary Designator) CW-PG110.
      6. Design Pressure (DP): +200/-110 psf (+9.58/-5.27 kPa).
      7. Water Test Pressure: 15 psf (0.72 kPa) with no leakage at 5 gallons per minute spray rate.
      8. Canadian Air Infiltration/Exfiltration Rating: A2. (1.5 L/s/m2 maximum)
      B. Unit Skylight Standard, 22  inch (559 mm) Unit: AAMA/WDMA/CSA 101/I.S.2/A440 (NAFS-11 or previous): 
      Specifier: Retain first four Subparagraphs below and delete following four Subparagraphs for IBC 2012 and 2015 code requirements; verify requirements of authorities having jurisdiction.
      1. Performance Grade (Primary Designator): TDDCC/TDDOC-PG130.
      2. Design Pressure (DP): +300/-130 psf (+14.4/-6.22 kPa).
      3. Water Test Pressure: 15 psf (0.72 kPa) with no leakage at 5 gallons per minute spray rate.
      4. Air Leakage Rate: 0.30 cfm/ft2 maximum
      Specifier: Delete first four Subparagraphs above and retain first four Subparagraphs below for IBC 2009 and NBC code requirements, including CSA A440S1-09; verify requirements of authorities having jurisdiction.
      5. Performance Class and Grade (Primary Designator): CW-PG100.
      6. Design Pressure (DP): +200/-100 psf (+9.58/-4.79 kPa).
      7. Water Test Pressure: 15 psf (0.72 kPa) with no leakage at 5 gallons per minute spray rate.
      8. Canadian Air Infiltration/Exfiltration Rating: A2 (1.5 L/s/m2 maximum).
      C. Daylighting: Provide daylighting photometric performance comparable to basis of design product at layout indicated, based upon daylighting profile of March 21, 9:00 am local time, at Project location by simulation in accordance with IESNA guidelines.
      D. Air Infiltration: Maximum air leakage through unit of 0.30 cfm/sq. ft. (1.5 L/s/sq. m) of fixed area as determined according to ASTM E 283 at a static-air-pressure differential of 1.57 lbf/sq. ft. (75Pa.)
      E. Water Penetration under Static Pressure: No evidence of water penetration through unit when tested according to ASTM E 331 at a static-air-pressure differential of 15 lbf/sq. ft. (720 Pa).
      Specifier: Retain "Windborne Debris Resistance" Paragraph if required by authorities having jurisdiction. Select optional polycarbonate glazing when retaining this Paragraph.
      F. Windborne-Debris Resistance: Provide tubular unit skylights capable of resisting impact from windborne debris, based on the pass/fail criteria as determined from testing glazed representative of those specified, according to ASTM E 1886 and ASTM E 1996.
      1. Missile Level C, Wind Zone 3 requirements, and +50/-50 psf cycle pressure minimum.
      G. Surface-Burning Characteristics of Plastic Glazing: Provide plastic glazing meeting NAFS and identical to specimens tested for fire-exposure behavior in accordance with test method indicated below by a testing and inspecting agency acceptable to authorities having jurisdiction. Identify materials with appropriate markings of applicable testing and inspecting agency.
      1. Self-Ignition Temperature: 650 deg F (345 deg. C) or more for plastic glazing in thickness indicated when tested per ASTM D 1929.
      2. Smoke-Production Characteristics: Comply with either requirement below:
      a. Smoke-Developed Index: 450 or less when tested per ASTM E 84 on plastic glazing in manner indicated for application.
      b. Smoke Density: 75 or less when tested per ASTM D 2843 on plastic glazing in thickness indicated for application.
      3. Burning Characteristics: Tested and labeled in accordance with ASTM D 635.
      a. Plastic Glazing for Domes: [Polycarbonate Class CC1] [Acrylic Class CC2].
      H. Fire Ratings for Roof Assemblies with Fire Classifications: Tubular unit skylight with dome edge protection band tested in accordance with ASTM E 108 and listed as passing Burning Brand test with target classification of Class B
      I. Energy Performance with Energy Kit Installed:
      1. Thermal Transmittance: NFRC 100 maximum U-factor: 
      a. 14 inch (356 mm) Units: 0.55 Btu/hr*ft2*deg F (3.12 W/m2*deg C).
      b. 22 inch (559 mm) Units: 0.43 Btu/hr*ft2*deg F (2.44 W/m2*deg C).
      2. Solar Heat-Gain Coefficient (SHGC): NFRC 200 maximum SHGC: 
      a. 14 inch (356 mm) Units: 0.28.
      b. 22 inch (559 mm) Units: 0.26.
      Specifier: Retain "Electrical Components" Paragraph below if retaining requirement for dimmer.
      J. Electrical Components: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application.
      K. Fall Protection Standard Compliance: 29 CFR 1910.23: Passed.



    Spécifications techniques
    • Réference unique.velux-skylight-tgc
    • Famille de produitsWindows
    • Groupe de produitsSkylights
    • Numéro d'édition1
    • Hauteur (mm)37.25
    • Largeur (mm)37.25
    • Profondeur (mm)19
    En rapport
    • Matériel principalVerre
    • Conçu enÉtats-Unis
    • Fabriqué enÉtats-Unis
    • Poids net (Kg)33
    Classification
    • BIMobject CatégorieFenêtres - Puits de lumière
    • Code Uniclass 2015Pr_30_59_72_77
    • Description de l'Uniclass 2015Skylights
    • Code CSI MasterFormat 201408 62 23
    • Titre CSI MasterFormat 2014Tubular Skylights
    • Numéro OmniClass23-17 17 13 21
    • Titre OmniClassTubular Skylights

    Disponibilité de la région

    Océanie Amérique du Nord Amérique du Sud
    Fidji
    Canada
    Chili
    Guam
    États-Unis
    Île Norfolk
    Mexique
    Îles Cook
    Îles Mariannes du Nord
    Îles Marshall
    Îles Pitcairn
    Îles Salomon
    Kiribati
    Micronésie
    Nauru
    Niué
    Nouvelle-Calédonie
    Nouvelle-Zélande
    Palaos
    Polynésie française
    Samoa
    Samoa américaines
    Timor-Leste
    Tokelau
    Tonga
    Tuvalu
    United States Minor Outlying Islands
    Vanuatu
    Wallis et Futuna