Publier vos produits
Rada 320 IC Thermostatic Mixing Valve
RADA

Rada 320 IC Thermostatic Mixing Valve

Traduit par Google,
Mitigeur thermostatique adapté à la douche de groupe, incorporant la cartouche Radatherm Rada 320 IC est un mitigeur thermostatique de groupe incorporant le capteur de température breveté Radatherm, des robinets à boisseau sphérique d'isolement, des clapets anti-retour, des isolateurs intégrés, des points de test et des raccords.
Spécification
  • Product Reference

    Rada 320 IC Thermostatic Mixing Valve (1.1847.013)

    Standard product features

    Suitable for surface-mounted, medium to large group showering installations.

    Connections:

    Standard connections are hot - left, cold - right, outlet - top when facing the control. Note: The outlet can be altered to bottom outlet if required by repositioning the drain plug.

    Approvals:

    WRAS approved (Water Regulations Advisory Scheme).

    Operation:

    The temperature control knob allows the authorised user to select the required temperature within the range available. An integral temperature stop limits the maximum temperature to a present level and can only be reset by an authorised person (alternatively, the temperature knob can be locked in position after the desired temperature has been selected).

    Materials:

    Body: European 4MS Scheme Compliant Brass meeting DZR and Low Lead requirements.

    Temperature range:

    • Optimum thermostatic control range: 30°C–50°C.

    • Minimum cold water temperature: 1°C.

    • Maximum hot water temperature: 85°C.

    Pressures/ flow rate:

    • Minimum dynamic supply pressure: 0.1 bar.

    • Maximum supply static pressure: 10 bar.

    • Maximum pressure loss ratio: Should not exceed 10 : 1 in favour of either supply during flow.

    • Maximum pressure loss: Inlets to outlet is 5.6 bar, which equates to maximum 120 L/min flow rate at mid-blend.

    Note: Pressure loss is the pressure drop between the inlets and the outlet of the mixing valve when flow is taking place.

    • Minimum flow rate: 6 L/min at mid-blend with nominally equal supply pressures.

    • Maximum flow rate: 120 L/min (5.6 bar pressure loss).

    Note: Both hot and cold pressure should be nominally equal.

Spécifications techniques
  • Réference unique.Rada-320-IC-Thermostatic-Mixing-Valve
  • Famille de produitsSanitary
  • Groupe de produitsShowers
  • TypeObjet (objet simple)
  • Date de publication2022-08-04
  • Numéro d'édition1
En rapport
  • Matériel principalLaiton
  • Matériel secondaireChrome
  • Conçu enRoyaume-Uni
  • Fabriqué enRoyaume-Uni
Classification
  • BIMobject CatégorieSanitaires - Douches
  • Classification IFCObjet
  • Code Uniclass 2015Pr_40_20_87_81
  • Description de l'Uniclass 2015Shower thermostatic water supply sets

Disponibilité de la région

L'Europe
Allemagne
Belgique
Pays-Bas
Royaume-Uni