Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels
Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels
Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels
Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels
Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels
Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels
Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels

    Poly Max™ Polyester (PET Felt) Ceiling and Wall Panels

    Traduit par Google,

    Panneaux acoustiques pour murs et plafonds en polyester Poly Max™

    Les panneaux acoustiques en polyester Poly Max™ offrent une solution élégante et durable pour contrôler l'écho et la réverbération en intérieur. Conçus pour allier performance et esthétique, ces panneaux sont parfaits pour les applications murales et au plafond dans les espaces commerciaux, éducatifs et résidentiels.

    Fabriqués à partir de fibres 100 % polyester, dont 60 % de PET recyclé post-consommation et 40 % de PET vierge, les panneaux Poly Max sont non toxiques, hypoallergéniques, sans formaldéhyde et résistants aux moisissures et aux champignons. Ils répondent à la norme CDPH V1.2 relative aux faibles émissions de COV et peuvent contribuer au crédit LEED v4.1 EQ pour les matériaux à faibles émissions.

    Les panneaux Poly Max offrent un équilibre parfait entre prix abordable et design haut de gamme. Disponibles dans une large gamme de couleurs, ils peuvent également être personnalisés avec des graphismes imprimés ou des images de qualité photo pour s'intégrer harmonieusement à tous les intérieurs. Leur surface est adhésive et peut être sublimée par une gravure personnalisée, offrant un design unique tout en préservant la fonctionnalité acoustique.

    Les panneaux sont disponibles dans des dimensions standard, notamment des panneaux vierges légèrement surdimensionnés de 4' x 8', ainsi que des formats de 4' x 8' et de 2' x 4'. Des dimensions sur mesure et des découpes de formes complexes sont disponibles pour répondre aux exigences spécifiques du projet et à l'intention de conception.

    L'installation est simple et polyvalente, avec des options telles que le montage adhésif, les ancrages encliquetables RotoFast, les fixations mécaniques (vis) et les systèmes à barres en Z. Qu'ils soient appliqués aux murs ou aux plafonds, les panneaux Poly Max offrent des performances acoustiques constantes et une grande flexibilité de conception.

    Légers, sûrs à manipuler et faciles à découper sur place, ces panneaux offrent une solution idéale pour les traitements acoustiques qui ne compromettent ni le style ni la durabilité.

    DIMENSIONS : (standard) 23¾" × 47¾" (carreaux de plafond) 24" x 48" et 48" × 96"
    Tailles personnalisées disponibles, veuillez appeler pour plus de détails

    ÉPAISSEUR : 1/2", 1", 2"

    COULEURS : 1" et 2" d'épaisseur : Blanc, Beige, Noir et Argent
    1/2” d’épaisseur : Blanc, Beige, Beige, Marron, Argent, Gris, Noir, Bleu, Violet, Rouge, Orange, Citron vert
    Graphiques ou images imprimés personnalisés également disponibles

    INFLAMMABILITÉ : Classe A, classé au feu selon ASTM
    Indice de propagation de la flamme : 15
    Indice de développement de fumée : 250

    Spécification
    • SECTION 09 51 13

      Poly MaxTM Ceiling Panels

      PART 1 GENERAL

      1. SECTION INCLUDES
        1. Poly MaxTM polyester acoustical ceiling panels and accessories for ceiling installation.
      2. REFERENCES
        1. American Society for Testing and Materials (ASTM)
          1. ASTM C1338: Standard Test Method for Determining Fungi Resistance of Insulation Materials and Facings
          2. ASTM C423: Standard Test Method for Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
          3. ASTM E84: Standard Test Method for Surface Burning Characteristics of Building Materials.
          4. ASTM E795: Standard Practices for Mounting Test Specimens During Sound Absorption Tests
          5. ASTM E1477: Standard Test Method for Luminous Reflectance Factor of Acoustical Materials by Use of Integrating-Sphere Reflectometers
        2. California Department of Public Health (CDPH)
          1. CDPH Standard Method V1.2: Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers
        3. International Code Council (ICC)
          1. ICC IBC: International Building Code
      3. SUBMITTALS
        1. Product Data: Manufacturer’s data sheet and installation instructions.
        2. Samples: Submit, at minimum, a 4” x 4” sample for each type of specified acoustical panel.
        3. Test Reports: Upon request, submit certified test reports to verify specified product performance.
      4. MAINTENANCE MATERIAL
      5. Extra Materials:
        1. Extra materials shall be from the same production run as the original materials.
        2. Extra materials shall remain in the manufacturer’s original packaging and given to the building owner upon substantial completion of the work. Store extra materials per instructions as described in storage and handling requirements.
      6. QUALITY ASSURANCE
        1. Qualifications:
          1. Manufacturers: Provide acoustical ceiling panels from a single manufacturer.
          2. Installers: Utilize an installer having demonstrated experience on projects of comparable size and complexity.
        2. Performance Requirements:
          1. Surface Burning Characteristics: Acoustical panels to perform as specified when tested in accordance with ASTM E84. Acoustical panel surface burning performance should comply with the International Building Code and other local building code requirements.
          2. Acoustical Characteristics: Acoustical panels to perform as specified when tested in accordance with ASTM C423.
      7. DELIVERY, STORAGE, AND HANDLING
        1. Storage and Handling Requirements:
          1. Handle panels carefully to avoid any damage.
          2. Store panels indoors in a clean, cool, dry place, and out of direct sunlight.
          3. Store panels in a space where the ambient temperature and humidity conditions are being maintained at the levels indicated for the project when occupied for its intended use.
      8. SITE CONDITIONS
        1. Ambient Conditions:
          1. Maintain ambient temperature and humidity conditions at levels indicated for the project when occupied for its intended use.
          2. Do not install products under environmental conditions outside manufacturer’s recommended limits.
        2. Existing Conditions: Do not install ceiling panels until space is enclosed and weather proofed, wet work is completely dry, and work above ceilings is complete.
      9. WARRANTY
        1. Provide manufacturer’s written product warranty per Section 01 77 00 – Closeout Procedures.

      PART 2 PRODUCTS

      (Specifier Note: Red colored text below requires you to select an option before this specification can be completed. Options in red text are bound by parenthesis. Additional Poly Max information can be found on our website https://www.acousticalsurfaces.com

      1. MANUFACTURERS
        1. Acoustical Surfaces, Inc., 123 Columbia Court N, Chaska, MN 55318.
          Phone: 952-448-5300. Fax: 952-448-2613. Website: www.acousticalsurfaces.com
          DESCRIPTION
          1. Product: Poly MaxTM Ceiling Panels by Acoustical Surfaces, Inc.
          2. Product Options:
            1. Panel Composition: 100% polyester: 60% PET-recycled fiber, 40% PET-virgin fiber.
            2. Panel Thickness: (1/2”) / (1”) / (2”)
            3. Panel Density: (12.5lb pcf – 1/2" panels) / (7.5lb pcf – 1” panels) /
              (5lb pcf – 2” panels)
            4. Panel Size: (24” x 48”) / (48” x 96”) / (Custom Sizes up to 48” x 96”)
            5. Edge Profile: Square
            6. Color: 1/2" Color Options: (White) / (Black) / (Beige) / (Silver) / (Gray)
              / (Tan) / (Brown) / (Blue) / (Purple) / (Red) / (Orange) / (Lime) /
              (Custom Printed Graphics, images or patterns)
              1” and 2” Color Options: (White) / (Black) / (Beige) (Silver) /
              (Custom Printed Graphics)
            7. Mounting Method: (Adhesive) / (Direct Attach with mechanical fasteners) /
              (RotoFast Snap-On Anchors) / (Stick Pins and Washers)
          3. Product Performance:
            1. Acoustical Performance
              1. Noise Reduction Coefficient (NRC) per ASTM C423

        Thickness

        1/2"

        1”

        2”

        A Mount

        0.40

        0.70

        0.95

        D20 Mount

        0.55

        0.80

        0.90

        D40 Mount

        0.70

        0.85

        0.95

        1. Surface Burning Performance
          1. Fire Rating per ASTM E84: Class A.
        2. Material Property Performance
          1. Luminous Reflectance per ASTM E1477: 1/2” – 87. 1” – 83. 2” – 82.
          2. Fungal Growth per ASTM C1338: Pass (100% clear of fungal growth).
          3. VOC Levels per CDPH Standard Method V1.2: Passed (white).

        PART 3 EXECUTION

        1. EXAMINATION
          1. Verification of Conditions:
            1. Examine surfaces scheduled to received furred out or directly attached acoustical units for unevenness, irregularities or dampness that would affect quality and execution of work.
            2. All wet work in the installation area must be complete, cured, and dry prior to installation.
            3. Work above ceilings shall be complete, inspected, and accepted before ceiling work begins.
        2. INSTALLATION
        3. Comply with manufacturer’s instructions and recommendations for installation of ceiling panels and with industry standards.
        4. CLEANING
        5. Clean surfaces of ceiling panels per manufacturer’s instructions or recommendations.
        6. Remove and replace damaged or discolored material and material that cannot be properly cleaned.
        7. PROTECTION
        8. Protect installed work from damage due to subsequent construction activity, including temperature and humidity limitations and dust control, so that the work will be without damage and deterioration at the time of acceptance by the owner.

        END OF SECTION

    Spécifications techniques
    • Réference unique.acoustical-surfaces-poly-max-acoustical-panels
    • Famille de produitsAcoustical Ceiling Panels
    • Groupe de produitsECHO ELIMINATOR™
    • TypeObjet (objet simple)
    • Date de publication2012-07-23
    • Numéro d'édition1
    • Hauteur (pouces)48
    • Largeur (pouces)24
    • Profondeur (pouces)0.5
    En rapport
    • Matériel principalPolyester
    • Matériel secondairePET
    • Poids net (Lbs)12.5
    Classification
    • BIMobject CatégorieConstruction - Plafond
    • Classification IFCPlafond
    • Code Uniclass 2015Ss_25_25_05
    • Description de l'Uniclass 2015Acoustic panel systems
    • Code CSI MasterFormat 201409 51 00
    • Titre CSI MasterFormat 2014Acoustical Ceilings
    • Numéro OmniClass23-15 19 15 11 11
    • Titre OmniClassAcoustical Ceiling Tile
    • Code CSI UniFormat IIC3030
    • Titre CSI UniFormat IICeiling Finishes

    Disponibilité de la région

    Amérique du Nord
    Anguilla
    Antigua-et-Barbuda
    Aruba
    Bahamas
    Barbade
    Belize
    Bermudes
    Canada
    Costa Rica
    Cuba
    Curaçao
    Dominique
    El Salvador
    États-Unis
    Grenade
    Groenland
    Guadeloupe
    Guatemala
    Haïti
    Honduras
    Îles Caïmans
    Îles Turks et Caïques
    Îles Vierges britanniques
    Îles Vierges des États-Unis
    Jamaïque
    Martinique
    Mexique
    Montserrat
    Nicaragua
    Panama
    Pays-Bas caribéens
    Porto Rico
    Republique de Trinite et Tobago
    République dominicaine
    Saint-Barthélemy
    Saint-Kitts-et-Nevis
    Saint-Martin
    Saint-Martin
    Saint-Pierre-et-Miquelon
    Saint-Vincent et les Grenadines
    Sainte-Lucie