Julkaise tuotteesi
CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

CHV-TSTAT-FCU - Heating/Cooling Fan-Coil Thermostat

The CHV-TSTAT-FCU is a versatile heating and cooling thermostat for fan coil unit (FCU) HVAC systems. Relative humidity capability can be added through an external remote humidity sensor (sold separately). Although functional as a standalone thermostat, the CHV-TSTAT delivers greatly enhanced functionality as part of a complete home automation system from Crestron®. Available in white, black, or almond, the stylish wall mount design is a complement to any décor.

The large backlit LCD display, navigable using four simple pushbuttons, provides easy access to indoor and outdoor temperature and humidity readings, setpoint adjustments, system mode and fan status indicators, and setup menus. Climate control features include separate heating, cooling, and humidity setpoints with optional automatic changeover between heating and cooling modes. Adjustable anticipators prevent overshooting the set temperature, and continuous fan operation can be selected when needed for increased circulation.

Automation System Integration
Multiple Crestron thermostats may be networked via Cresnet® to any 3-Series® control system, including the DIN-AP3, enabling global temperature and humidity adjustment from any thermostat. Automation functions such as lighting, motorized blinds, or lawn sprinklers can be accessed through two custom remote function pages, and customized text messages can be sent to the LCD display to provide maintenance reminders and other alerts.

Its connection to the control system also allows for full control and scheduling of the CHV-TSTAT-FCU from touch screens and computers throughout the home, and supports extensive flexibility for integration with other devices and systems. In the event that communication with the control system is disrupted for any reason, the CHV-TSTAT-FCU will remain operable to control the HVAC system.

Remote Sensors
Optional remote temperature and humidity sensors can be connected to the CHV-TSTAT-FCU for enhanced flexibility and optimized performance. Climate can be regulated according to an average of multiple sensors, or the built-in sensors can be disabled entirely to allow the CHV-TSTAT-FCU to be installed out of view. Outdoor climate can also be monitored, enabling outdoor low-temperature compensation to prevent condensation on windows during cold weather. The CHV-TSTAT-FCU accepts up to four remote temperature sensors, two remote temp/humidity sensors, or a combination of one temp/humidity sensor and two temperature sensors.

Features
Summary Of Features

Wall-mount thermostat for fan coil unit HVAC systems
Multiple Crestron® thermostats may be networked via Cresnet®
Supports remote humidity sensors and outdoor temperature sensors
Backlit LCD display
Front panel buttons for setup, configuring, and temperature and humidity adjustments[1]
Available in white, black, or almond finishes

Notes:
1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Tekniset tiedot
  • Measurement Range
     
    Indoor Temperature: 0° to 110°F (-18° to 43°C)
    Outdoor Temperature: -40° to 170°F (-40° to 77°C)[1]
    Humidity: 0% to 100% RH[1]

    Temperature Tolerance
    Over Full Range: ±1°F (±0.5°C)
    At Room Temperatures: ±1°F (+0.1/-0.4°C)

    Setpoint Range
    Auto Setpoint: 38° to 99°F (3° to 37°C)
    Heat only Setpoint: 38° to 89°F (3° to 32°C)
    Cool only Setpoint: 59° to 99°F (15° to 37°C), or 38° to 99°F (3° to 37°C) extended cool mode enabled
    Humidity Setpoint:5% to 70% RH[1]

    Relay Rating
    1 Amp at 40 Volts DC or 24 Volts AC (nominal)

    Power Requirements
    24V: 2 Watts (0.083 Amps) at 24 Volts AC, supplied by heating or cooling system
    Cresnet® Power Usage: ‹1 Watts (‹0.05 Amps at 24 Volts DC), required for Cresnet communication only

    Buttons
    MODE: Accesses user controls - system mode, fan mode, humidifier,[1] Crestron® system, and global update
    VIEW: Accesses humidity reading,[1] outdoor temperature reading,[1] system messages, and remote functions
    UP: Selects user modes and increments selection in setup modes
    DOWN: Selects user modes and decrements selection in setup modes

    Display
    Type: Transflective LCD, backlit
    Size: 2.75 in (6.99 cm)
    Resolution: 128 x 64
    Viewing Angle: ±50° horizontal (at 0° vertical), ±50° vertical (at 0° horizontal)
    Displays current indoor temperature and relative humidity,[1] outdoor temperature and relative humidity,[1] setpoints, activity, function, Cresnet system information, internal relay status, setup menus, and control system messages

    Connections
    HVAC:
    (2) 9-position terminal blocks comprising the following:

    Power Connections (Required):
    24 (C): 24V AC common terminal supplies remote 24V AC power to thermostat;
    24 (R): 24V AC reference terminal – Can be connected to R by P4 jumper setting, or tied directly to power source

    HVAC Control Connections (System Dependent):
    HUM, RHU: Humidity Control – Energized together during humidity call;
    R, R: Reference – Used for all system calls (except humidity);
    G-L: Fan Low – Energized to R during call for low-speed fan;
    G-M: Fan – Energized to R during call for medium-speed fan;
    G-H: Fan – Energized to R during call for high-speed fan;
    O: Changeover control – Energized to R during cooling modes;
    B: Energized to R during non-cooling modes;
    W: Heat – Energized to R during call for heating;
    Y: Cool – Energized to R during call for cooling

    Remote Sensing Connections (Optional):
    RSR: Remote Sensor Returns – Common sensor terminal;
    RS1: Remote Sensor terminal – Connect the sensor from RS1 to RSR;
    RS2: Remote Sensor terminal – Connect the sensor from RS2 to RSR
     
    Network
    (1) 4-position terminal block;
    Cresnet slave port, connects to Cresnet control network

    Enclosure
    Plastic, surface-mountable to the front of a horizontally oriented 1-gang electrical box

    Dimensions
    Height: 3.75 in (96 mm)
    Width: 5.00 in (127 mm)
    Depth: 1.04 in (27 mm)
    Weight: 5.80 oz (165 g)

    Notes:
    1. Humidity sensing and outdoor temperature/humidity sensing require additional remote sensors, sold separately. See “Available Accessories” for model names.

Tekniset tiedot
  • Yksilöity viitecrestron-CHV-TSTAT-FCU
  • TuoteperheLighting & Environment
  • TuoteryhmäClimate Control
  • TyyppiObjekti (yksittäinen objekti)
  • Julkaisupäivä2017-12-10
  • Painoksen numero1
  • Korkeus (tuumaa)3.75
  • Leveys (tuumaa)5
  • Syvyys (tuumaa)1.04
Liittyviä
  • Ensisijainen materiaaliMuovi
  • Suunniteltu:Meksiko
  • Valmistettu:Meksiko
  • Nettopaino (paunaa)0.3625
Luokitus
  • BIMobject-luokkaElektroniikka - Controls
  • IFC-luokitusSähköelementti
  • CSI MasterFormat 2014 -koodi40 74 00
  • CSI MasterFormat 2014 -nimikeTemperature Measurement
  • OmniClass-numero23-27 11 11 15 11
  • OmniClass-nimikeDigital Temperature Controllers

Alueellinen saatavuus

Eurooppa Aasia Pohjois-Amerikka Afrikka Etelä-Amerikka Oseania
Ahvenanmaa
Afganistan
Anguilla
Algeria
Argentiina
Amerikan Samoa
Alankomaat
Arabiemiirikunnat
Antigua ja Barbuda
Angola
Bolivia
Australia
Albania
Armenia
Aruba
Benin
Brasilia
Cooksaaret
Andorra
Azerbaidžan
Bahamasaaret
Botswana
Chile
Fidzi
Belgia
Bahrain
Barbados
Burkina Faso
Ecuador
Guam
Bosnia ja Hertsegovina
Bangladesh
Belize
Burundi
Falklandinsaaret (Malvinassaaret)
Kiribati
Bulgaria
Bhutan
Bermuda
Djibouti
Guyana
Marshallsaaret
Espanja
Brittiläinen Intian valtameren alue
Brittiläiset Neitsytsaaret
Egypti
Kolumbia
Mikronesian liittovaltio
Färsaaret
Brunei
Caribbean Netherlands
Eritrea
Paraguay
Nauru
Gibraltar
Etelä-Korea
Caymansaaret
Etelä-Afrikka
Peru
Niue
Guernsey
Filippiinit
Costa Rica
Etelä-Sudan
Ranskan Guayana
Norfolkinsaari
Huippuvuoret
Georgia
Curaçao
Etiopia
Surinam
Palau
Irlanti
Hong Kong
Dominica
Gabon
Uruguay
Papua-Uusi-Guinea
Islanti
Indonesia
Dominikaaninen tasavalta
Gambia
Venezuela
Pitcairnsaaret
Italia
Intia
El Salvador
Ghana
Pohjois-Mariaanit
Itävalta
Irak
Grenada
Guinea
Ranskan Polynesia
Jersey
Iran
Grönlanti
Guinea-Bissau
Salomonsaaret
Kreikka
Israel
Guadeloupe
Kamerun
Samoa
Kroatia
Japani
Guatemala
Kap Verde
Timor-Leste
Kypros
Jemen
Haiti
Kenia
Tokelau
Latvia
Jordania
Honduras
Keski-Afrikan tasavalta
Tonga
Liechtenstein
Joulusaari
Jamaika
Komorit
Tuvalu
Liettua
Kambodža
Kanada
Kongo
United States Minor Outlying Islands
Luxemburg
Kazakstan
Kuuba
Kongon demokraattinen tasavalta
Uusi-Kaledonia
Malta
Kiina
Martinique
Länsi-Sahara
Uusi-Seelanti
Mansaari
Kirgisia
Meksiko
Lesotho
Vanuatu
Moldova
Kookossaaret
Montserrat
Liberia
Wallis ja Futuna
Monaco
Kuwait
Nicaragua
Libya
Montenegro
Laos
Panama
Madagaskar
Norja
Libanon
Puerto Rico
Malawi
Pohjois-Makedonia
Macao
Saint Kitts ja Nevis
Mali
Portugali
Malediivit
Saint Lucia
Marokko
Puola
Malesia
Saint Vincent ja Grenadiinit
Mauritania
Ranska
Mongolia
Saint-Barthélemy
Mauritius
Romania
Myanmar (Burma)
Saint-Martin
Mayotte
Ruotsi
Nepal
Saint-Pierre ja Miquelon
Mosambik
Saksa
Oman
Sint Maarten
Namibia
San Marino
Pakistan
Trinidad ja Tobago
Niger
Serbia
Palestiinalaisalueet
Turks- ja Caicossaaret
Nigeria
Slovakia
Pohjois-Korea
Yhdysvallat
Norsunluurannikko
Slovenia
Qatar
Yhdysvaltain Neitsytsaaret
Päiväntasaajan Guinea
Suomi
Saudi-Arabia
Reunion
Sveitsi
Singapore
Ruanda
Tanska
Sri Lanka
Saint Helena
Tsekin tasavalta
Syyria
Sambia
Ukraina
Tadžikistan
São Tomé ja Príncipe
Unkari
Taiwan
Senegal
Valko-Venäjä
Thaimaa
Seychellit
Vatikaanivaltio
Turkki
Sierra Leone
Venäjä
Turkmenistan
Somalia
Viro
Uzbekistan
Sudan
Yhdistynyt kuningaskunta
Vietnam
Swasimaa
Tansania
Togo
Tsad
Tunisia
Uganda
Zimbabwe